dc.description.abstractReal-time aerosol measuring instruments have been widely used for the measurement of atmospheric aerosol, diesel particulate matter, or material synthesis. A scanning mobility particle sizer (SMPS) measures the number size distribution of particles using electrical mobility detection technique. An aerodynamic particle sizer (APS) is used to determine the number concentration and the mean aerodynamic diameter of test particles. An electrical low-pressure impactor (ELPI) is a multi-stage impaction device to separate airborne particles into aerodynamic size classes using particle charging and electrical detection techniques. In this study, the performance of these instruments were evaluated to assess their ability to obtain mass concentrations from particle number concentration measurements made as a function of particle size. The effect of determination of particle density on the measurement of mass concentration was investigated for the three instruments.-
dc.languageKorean-
dc.publisher한국입자에어로졸학회-
dc.title실시간 에어로졸 측정장비를 이용한 대기 중 입자상 물질의 무게 농도 분포의 추정-
dc.title.alternativeEstimation of Mass Size Distribution of Atmospheric Aerosols Using Real-Time Aerosol Measuring Instruments-
dc.typeArticle-
dc.identifier.doi10.11629/jpaar.2013.9.2.039-
dc.description.journalClass2-
dc.identifier.bibliographicCitationPARTICLE AND AEROSOL RESEARCH, v.9, no.2, pp.39 - 50-
dc.citation.titlePARTICLE AND AEROSOL RESEARCH-
dc.citation.volume9-
dc.citation.number2-
dc.citation.startPage39-
dc.citation.endPage50-
dc.description.journalRegisteredClasskci-
dc.description.journalRegisteredClassother-
dc.identifier.kciidART001788024-
dc.subject.keywordAuthorSize distribution-
dc.subject.keywordAuthorMass concentration-
dc.subject.keywordAuthorSMPS-
dc.subject.keywordAuthorAPS-
dc.subject.keywordAuthorELPI-
dc.subject.keywordAuthorParticle density-
dc.subject.keywordAuthorSize distribution-
dc.subject.keywordAuthorMass concentration-
dc.subject.keywordAuthorSMPS-
dc.subject.keywordAuthorAPS-
dc.subject.keywordAuthorELPI-
dc.subject.keywordAuthorParticle density-
Appears in Collections:
KIST Article > 2013
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE