TGA-GC/MS - an Adjuvant Tool for Analysis of Polymer Membranes Designed for Fuel Cell Use

Title
TGA-GC/MS - an Adjuvant Tool for Analysis of Polymer Membranes Designed for Fuel Cell Use
Authors
Wiebke GermerJanine LeppinCarolina Nunes Kirchner헨켄스마이어디억Alexander Dyck
Keywords
TGA GC MS; anion exchange membrane
Issue Date
2012-09
Publisher
Euromembrane
Abstract
The applied preparation procedure of membrane submersion in an aqueous salt solution for 24 h is a widespread method for ion exchange in polymer membranes.[3-5] The present TGA-GC/MS analysis shows that in some cases this method has to be regarded with caution as the ion exchange might not be complete. To obtain reliable electrochemical data (e.g. conductivity) of PBI-CO32- in further studies, modification of the ion exchange procedure is recommended. The hyphenation of TGA and GC/MS is an adjuvant tool for the investigation of materials like polymer membranes for fuel cell use as the degradation products of each decomposition step can be analyzed separately to get useful information for further improvement of the material stability. Furthermore the progress of preparation processes can be monitored, as it was exemplified in this work by the ion exchange in a polybenzimidazolium membrane.
URI
http://pubs.kist.re.kr/handle/201004/43140
Appears in Collections:
KIST Publication > Conference Paper
Files in This Item:
There are no files associated with this item.