<?xml version="1.0" encoding="utf-8" standalone="no"?>
<dublin_core schema="dc">
<dcvalue element="contributor" qualifier="author">Yim,&#x20;Sehyuk</dcvalue>
<dcvalue element="contributor" qualifier="author">Jeong,&#x20;Jinwoo</dcvalue>
<dcvalue element="contributor" qualifier="author">Ihn,&#x20;Yongsuk</dcvalue>
<dcvalue element="contributor" qualifier="author">Hwang,&#x20;Donghyun</dcvalue>
<dcvalue element="contributor" qualifier="author">Yang,&#x20;Sungwook</dcvalue>
<dcvalue element="contributor" qualifier="author">Oh,&#x20;Sang-Rok</dcvalue>
<dcvalue element="contributor" qualifier="author">Kim,&#x20;Keehoon</dcvalue>
<dcvalue element="date" qualifier="accessioned">2024-01-19T09:09:55Z</dcvalue>
<dcvalue element="date" qualifier="available">2024-01-19T09:09:55Z</dcvalue>
<dcvalue element="date" qualifier="created">2022-03-07</dcvalue>
<dcvalue element="date" qualifier="issued">2020-07</dcvalue>
<dcvalue element="identifier" qualifier="issn">1557-170X</dcvalue>
<dcvalue element="identifier" qualifier="uri">https:&#x2F;&#x2F;pubs.kist.re.kr&#x2F;handle&#x2F;201004&#x2F;113598</dcvalue>
<dcvalue element="description" qualifier="abstract">This&#x20;paper&#x20;presents&#x20;a&#x20;neurosurgical&#x20;device&#x20;called&#x20;NEIT&#x20;2&#x20;(Nerve&#x20;Electrode&#x20;Insertion&#x20;Tool)&#x20;to&#x20;implant&#x20;a&#x20;3D&#x20;microelectrode&#x20;array&#x20;into&#x20;a&#x20;peripheral&#x20;nervous&#x20;system.&#x20;Using&#x20;an&#x20;elastomer-made&#x20;nerve&#x20;holder,&#x20;the&#x20;device&#x20;is&#x20;able&#x20;to&#x20;stable&#x20;target&#x20;a&#x20;flexible&#x20;nerve,&#x20;and&#x20;then&#x20;safely&#x20;inserts&#x20;an&#x20;electrode&#x20;array&#x20;into&#x20;the&#x20;fixed&#x20;nerve.&#x20;Finally,&#x20;a&#x20;nerve&#x20;containment&#x20;assembly&#x20;is&#x20;made&#x20;at&#x20;once.&#x20;We&#x20;conducted&#x20;animal&#x20;experiments&#x20;to&#x20;evaluate&#x20;the&#x20;proposed&#x20;scenario&#x20;using&#x20;a&#x20;3D&#x20;printed&#x20;prototype&#x20;and&#x20;commercial&#x20;microelectrodes.&#x20;The&#x20;results&#x20;show&#x20;that&#x20;microelectrodes&#x20;are&#x20;successfully&#x20;implanted&#x20;into&#x20;sciatic&#x20;nerves&#x20;of&#x20;rats&#x20;and&#x20;neural&#x20;signals&#x20;are&#x20;recorded&#x20;through&#x20;the&#x20;chronically&#x20;implanted&#x20;electrodes.</dcvalue>
<dcvalue element="language" qualifier="none">English</dcvalue>
<dcvalue element="publisher" qualifier="none">IEEE</dcvalue>
<dcvalue element="title" qualifier="none">One-step&#x20;Implantation&#x20;of&#x20;a&#x20;3D&#x20;Neural&#x20;Microelectrode&#x20;Array</dcvalue>
<dcvalue element="type" qualifier="none">Conference</dcvalue>
<dcvalue element="description" qualifier="journalClass">1</dcvalue>
<dcvalue element="identifier" qualifier="bibliographicCitation">42nd&#x20;Annual&#x20;International&#x20;Conference&#x20;of&#x20;the&#x20;IEEE-Engineering-in-Medicine-and-Biology-Society&#x20;(EMBC),&#x20;pp.3379&#x20;-&#x20;3383</dcvalue>
<dcvalue element="citation" qualifier="title">42nd&#x20;Annual&#x20;International&#x20;Conference&#x20;of&#x20;the&#x20;IEEE-Engineering-in-Medicine-and-Biology-Society&#x20;(EMBC)</dcvalue>
<dcvalue element="citation" qualifier="startPage">3379</dcvalue>
<dcvalue element="citation" qualifier="endPage">3383</dcvalue>
<dcvalue element="citation" qualifier="conferencePlace">US</dcvalue>
<dcvalue element="citation" qualifier="conferencePlace">Montreal,&#x20;CANADA</dcvalue>
<dcvalue element="citation" qualifier="conferenceDate">2020-07-20</dcvalue>
<dcvalue element="relation" qualifier="isPartOf">42ND&#x20;ANNUAL&#x20;INTERNATIONAL&#x20;CONFERENCES&#x20;OF&#x20;THE&#x20;IEEE&#x20;ENGINEERING&#x20;IN&#x20;MEDICINE&#x20;AND&#x20;BIOLOGY&#x20;SOCIETY:&#x20;ENABLING&#x20;INNOVATIVE&#x20;TECHNOLOGIES&#x20;FOR&#x20;GLOBAL&#x20;HEALTHCARE&#x20;EMBC&amp;apos;20</dcvalue>
<dcvalue element="identifier" qualifier="wosid">000621592203178</dcvalue>
<dcvalue element="identifier" qualifier="scopusid">2-s2.0-85091025666</dcvalue>
</dublin_core>
