<?xml version="1.0" encoding="utf-8" standalone="no"?>
<dublin_core schema="dc">
<dcvalue element="contributor" qualifier="author">Lee,&#x20;Jaemin</dcvalue>
<dcvalue element="contributor" qualifier="author">Hwang,&#x20;Donghyun</dcvalue>
<dcvalue element="contributor" qualifier="author">Kim,&#x20;Minkyu</dcvalue>
<dcvalue element="contributor" qualifier="author">Kim,&#x20;Keehoon</dcvalue>
<dcvalue element="date" qualifier="accessioned">2024-01-19T11:38:15Z</dcvalue>
<dcvalue element="date" qualifier="available">2024-01-19T11:38:15Z</dcvalue>
<dcvalue element="date" qualifier="created">2022-03-07</dcvalue>
<dcvalue element="date" qualifier="issued">2016</dcvalue>
<dcvalue element="identifier" qualifier="issn">2155-1782</dcvalue>
<dcvalue element="identifier" qualifier="uri">https:&#x2F;&#x2F;pubs.kist.re.kr&#x2F;handle&#x2F;201004&#x2F;114987</dcvalue>
<dcvalue element="description" qualifier="abstract">This&#x20;paper&#x20;presents&#x20;development&#x20;of&#x20;a&#x20;two-fingered&#x20;robotic&#x20;device&#x20;for&#x20;amputees&#x20;whose&#x20;hands&#x20;are&#x20;partially&#x20;impaired.&#x20;In&#x20;this&#x20;research,&#x20;we&#x20;focused&#x20;on&#x20;developing&#x20;a&#x20;compact&#x20;and&#x20;lightweight&#x20;robotic&#x20;finger&#x20;system,&#x20;so&#x20;the&#x20;target&#x20;amputee&#x20;would&#x20;be&#x20;able&#x20;to&#x20;execute&#x20;simple&#x20;activities&#x20;in&#x20;daily&#x20;living&#x20;(ADL),&#x20;such&#x20;as&#x20;grasping&#x20;a&#x20;bottle&#x20;or&#x20;a&#x20;cup&#x20;for&#x20;a&#x20;long&#x20;time.&#x20;The&#x20;robotic&#x20;finger&#x20;module&#x20;was&#x20;designed&#x20;by&#x20;considering&#x20;the&#x20;impaired&#x20;shape&#x20;and&#x20;physical&#x20;specifications&#x20;of&#x20;the&#x20;target&#x20;patient&amp;apos;s&#x20;hand.&#x20;The&#x20;proposed&#x20;prosthetic&#x20;finger&#x20;was&#x20;designed&#x20;using&#x20;a&#x20;linkage&#x20;mechanism&#x20;which&#x20;was&#x20;able&#x20;to&#x20;create&#x20;underactuated&#x20;finger&#x20;motion.&#x20;This&#x20;underactuated&#x20;mechanism&#x20;contributes&#x20;to&#x20;minimizing&#x20;the&#x20;number&#x20;of&#x20;required&#x20;actuators&#x20;for&#x20;finger&#x20;motion.&#x20;In&#x20;addition,&#x20;the&#x20;robotic&#x20;finger&#x20;was&#x20;not&#x20;driven&#x20;by&#x20;an&#x20;electro-magnetic&#x20;rotary&#x20;motor,&#x20;but&#x20;a&#x20;shape-memory&#x20;alloy&#x20;(SMA)&#x20;actuator.&#x20;Having&#x20;a&#x20;driving&#x20;method&#x20;using&#x20;SMA&#x20;wire&#x20;contributed&#x20;to&#x20;reducing&#x20;the&#x20;total&#x20;weight&#x20;of&#x20;the&#x20;prosthetic&#x20;robot&#x20;finger&#x20;as&#x20;it&#x20;has&#x20;higher&#x20;energy&#x20;density&#x20;than&#x20;that&#x20;offered&#x20;by&#x20;the&#x20;method&#x20;using&#x20;the&#x20;electrical&#x20;DC&#x20;motor.&#x20;In&#x20;this&#x20;paper,&#x20;we&#x20;confirmed&#x20;the&#x20;performance&#x20;of&#x20;the&#x20;proposed&#x20;robotic&#x20;finger&#x20;by&#x20;fundamental&#x20;driving&#x20;tests&#x20;and&#x20;the&#x20;characterization&#x20;of&#x20;the&#x20;SMA&#x20;actuator.</dcvalue>
<dcvalue element="language" qualifier="none">English</dcvalue>
<dcvalue element="publisher" qualifier="none">IEEE</dcvalue>
<dcvalue element="title" qualifier="none">A&#x20;Feasibility&#x20;Test&#x20;of&#x20;Underactuated&#x20;Robotic&#x20;Prosthetic&#x20;Fingers&#x20;Actuated&#x20;by&#x20;Shape&#x20;Memory&#x20;Alloy</dcvalue>
<dcvalue element="type" qualifier="none">Conference</dcvalue>
<dcvalue element="description" qualifier="journalClass">1</dcvalue>
<dcvalue element="identifier" qualifier="bibliographicCitation">6th&#x20;IEEE&#x20;International&#x20;Conference&#x20;on&#x20;Biomedical&#x20;Robotics&#x20;and&#x20;Biomechatronics&#x20;(BioRob),&#x20;pp.554&#x20;-&#x20;560</dcvalue>
<dcvalue element="citation" qualifier="title">6th&#x20;IEEE&#x20;International&#x20;Conference&#x20;on&#x20;Biomedical&#x20;Robotics&#x20;and&#x20;Biomechatronics&#x20;(BioRob)</dcvalue>
<dcvalue element="citation" qualifier="startPage">554</dcvalue>
<dcvalue element="citation" qualifier="endPage">560</dcvalue>
<dcvalue element="citation" qualifier="conferencePlace">US</dcvalue>
<dcvalue element="citation" qualifier="conferencePlace">SINGAPORE</dcvalue>
<dcvalue element="citation" qualifier="conferenceDate">2016-06-26</dcvalue>
<dcvalue element="relation" qualifier="isPartOf">2016&#x20;6TH&#x20;IEEE&#x20;INTERNATIONAL&#x20;CONFERENCE&#x20;ON&#x20;BIOMEDICAL&#x20;ROBOTICS&#x20;AND&#x20;BIOMECHATRONICS&#x20;(BIOROB)</dcvalue>
<dcvalue element="identifier" qualifier="wosid">000392266900095</dcvalue>
<dcvalue element="identifier" qualifier="scopusid">2-s2.0-84983426918</dcvalue>
<dcvalue element="type" qualifier="docType">Proceedings&#x20;Paper</dcvalue>
</dublin_core>
