<?xml version="1.0" encoding="utf-8" standalone="no"?>
<dublin_core schema="dc">
<dcvalue element="contributor" qualifier="author">Lee,&#x20;Byeungleul</dcvalue>
<dcvalue element="contributor" qualifier="author">Jeong,&#x20;Jinwoo</dcvalue>
<dcvalue element="contributor" qualifier="author">Cho,&#x20;Chanseob</dcvalue>
<dcvalue element="contributor" qualifier="author">Kim,&#x20;Jinseok</dcvalue>
<dcvalue element="contributor" qualifier="author">Kim,&#x20;Bonghwan</dcvalue>
<dcvalue element="contributor" qualifier="author">Kim,&#x20;Hyeon&#x20;Cheol</dcvalue>
<dcvalue element="contributor" qualifier="author">Chun,&#x20;Kukjin</dcvalue>
<dcvalue element="date" qualifier="accessioned">2024-01-19T12:09:45Z</dcvalue>
<dcvalue element="date" qualifier="available">2024-01-19T12:09:45Z</dcvalue>
<dcvalue element="date" qualifier="created">2022-03-07</dcvalue>
<dcvalue element="date" qualifier="issued">2013</dcvalue>
<dcvalue element="identifier" qualifier="uri">https:&#x2F;&#x2F;pubs.kist.re.kr&#x2F;handle&#x2F;201004&#x2F;115433</dcvalue>
<dcvalue element="description" qualifier="abstract">We&#x20;developed&#x20;a&#x20;cantilever-arrayed&#x20;blood&#x20;pressure&#x20;sensor&#x20;array&#x20;fabricated&#x20;by&#x20;(111)&#x20;silicon&#x20;bulk-micromachining&#x20;for&#x20;the&#x20;noninvasive&#x20;and&#x20;continuous&#x20;measurement&#x20;of&#x20;blood&#x20;pressure.&#x20;The&#x20;blood&#x20;pressure&#x20;sensor&#x20;measures&#x20;the&#x20;blood&#x20;pressure&#x20;based&#x20;on&#x20;the&#x20;change&#x20;in&#x20;resistance&#x20;of&#x20;the&#x20;piezoresistor&#x20;on&#x20;a&#x20;5-mu&#x20;m-thick-arrayed&#x20;perforated&#x20;membrane&#x20;and&#x20;20-mu&#x20;m-thick&#x20;metal&#x20;pads.&#x20;The&#x20;length&#x20;and&#x20;width&#x20;of&#x20;the&#x20;unit&#x20;membrane&#x20;are&#x20;210&#x20;and&#x20;310&#x20;mu&#x20;m,&#x20;respectively.&#x20;The&#x20;width&#x20;of&#x20;the&#x20;insensible&#x20;zone&#x20;between&#x20;adjacent&#x20;units&#x20;is&#x20;only&#x20;10&#x20;mu&#x20;m.&#x20;The&#x20;resistance&#x20;change&#x20;over&#x20;contact&#x20;force&#x20;was&#x20;measured&#x20;to&#x20;verify&#x20;the&#x20;performance.&#x20;The&#x20;good&#x20;linearity&#x20;of&#x20;the&#x20;result&#x20;confirmed&#x20;that&#x20;the&#x20;PDMS&#x20;package&#x20;transfers&#x20;the&#x20;forces&#x20;appropriately.&#x20;The&#x20;measured&#x20;sensitivity&#x20;was&#x20;about&#x20;4.5%&#x2F;N.&#x20;The&#x20;maximum&#x20;measurement&#x20;range&#x20;and&#x20;resolution&#x20;of&#x20;the&#x20;fabricated&#x20;blood&#x20;pressure&#x20;sensor&#x20;were&#x20;greater&#x20;than&#x20;900&#x20;mmHg&#x20;and&#x20;less&#x20;than&#x20;1&#x20;mmHg,&#x20;respectively.</dcvalue>
<dcvalue element="language" qualifier="none">English</dcvalue>
<dcvalue element="publisher" qualifier="none">IEEE</dcvalue>
<dcvalue element="title" qualifier="none">Cantilever&#x20;Arrayed&#x20;Blood&#x20;Pressure&#x20;Sensor&#x20;for&#x20;Arterial&#x20;Applanation&#x20;Tonometry</dcvalue>
<dcvalue element="type" qualifier="none">Conference</dcvalue>
<dcvalue element="description" qualifier="journalClass">1</dcvalue>
<dcvalue element="identifier" qualifier="bibliographicCitation">8th&#x20;Annual&#x20;IEEE&#x20;International&#x20;Conference&#x20;on&#x20;Nano&#x2F;Micro&#x20;Engineered&#x20;and&#x20;Molecular&#x20;Systems&#x20;(NEMS),&#x20;pp.907&#x20;-&#x20;910</dcvalue>
<dcvalue element="citation" qualifier="title">8th&#x20;Annual&#x20;IEEE&#x20;International&#x20;Conference&#x20;on&#x20;Nano&#x2F;Micro&#x20;Engineered&#x20;and&#x20;Molecular&#x20;Systems&#x20;(NEMS)</dcvalue>
<dcvalue element="citation" qualifier="startPage">907</dcvalue>
<dcvalue element="citation" qualifier="endPage">910</dcvalue>
<dcvalue element="citation" qualifier="conferencePlace">US</dcvalue>
<dcvalue element="citation" qualifier="conferencePlace">Suzhou,&#x20;PEOPLES&#x20;R&#x20;CHINA</dcvalue>
<dcvalue element="citation" qualifier="conferenceDate">2013-04-07</dcvalue>
<dcvalue element="relation" qualifier="isPartOf">2013&#x20;8TH&#x20;ANNUAL&#x20;IEEE&#x20;INTERNATIONAL&#x20;CONFERENCE&#x20;ON&#x20;NANO&#x2F;MICRO&#x20;ENGINEERED&#x20;AND&#x20;MOLECULAR&#x20;SYSTEMS&#x20;(IEEE&#x20;NEMS&#x20;2013)</dcvalue>
<dcvalue element="identifier" qualifier="wosid">000327183000193</dcvalue>
<dcvalue element="identifier" qualifier="scopusid">2-s2.0-84883120979</dcvalue>
<dcvalue element="type" qualifier="docType">Proceedings&#x20;Paper</dcvalue>
</dublin_core>
