<?xml version="1.0" encoding="utf-8" standalone="no"?>
<dublin_core schema="dc">
<dcvalue element="contributor" qualifier="author">Yoon,&#x20;Siyeop</dcvalue>
<dcvalue element="contributor" qualifier="author">Yoon,&#x20;Chang&#x20;Hwan</dcvalue>
<dcvalue element="contributor" qualifier="author">Lee,&#x20;Deukhee</dcvalue>
<dcvalue element="date" qualifier="accessioned">2024-01-19T15:05:20Z</dcvalue>
<dcvalue element="date" qualifier="available">2024-01-19T15:05:20Z</dcvalue>
<dcvalue element="date" qualifier="created">2021-09-05</dcvalue>
<dcvalue element="date" qualifier="issued">2021-03</dcvalue>
<dcvalue element="identifier" qualifier="issn">0169-2607</dcvalue>
<dcvalue element="identifier" qualifier="uri">https:&#x2F;&#x2F;pubs.kist.re.kr&#x2F;handle&#x2F;201004&#x2F;117323</dcvalue>
<dcvalue element="description" qualifier="abstract">Background&#x20;and&#x20;Objective:&#x20;Intra-operative&#x20;X-ray&#x20;angiography,&#x20;the&#x20;current&#x20;standard&#x20;method&#x20;for&#x20;visualizing&#x20;and&#x20;diagnosing&#x20;cardiovascular&#x20;disease,&#x20;is&#x20;limited&#x20;in&#x20;its&#x20;ability&#x20;to&#x20;provide&#x20;essential&#x20;3D&#x20;information.&#x20;These&#x20;limitations&#x20;are&#x20;disadvantages&#x20;in&#x20;treating&#x20;patients.&#x20;For&#x20;example,&#x20;it&#x20;is&#x20;a&#x20;cause&#x20;of&#x20;lowering&#x20;the&#x20;success&#x20;rate&#x20;of&#x20;interventional&#x20;procedures.&#x20;Here,&#x20;we&#x20;propose&#x20;a&#x20;novel&#x20;2D-3D&#x20;non-rigid&#x20;registration&#x20;method&#x20;to&#x20;understand&#x20;vascular&#x20;geometry&#x20;during&#x20;percutaneous&#x20;coronary&#x20;intervention.&#x20;Methods:&#x20;The&#x20;proposed&#x20;method&#x20;uses&#x20;the&#x20;local&#x20;bijection&#x20;pair&#x20;distance&#x20;as&#x20;a&#x20;cost&#x20;function&#x20;to&#x20;minimize&#x20;the&#x20;effect&#x20;of&#x20;inconsistencies&#x20;from&#x20;center-line&#x20;extraction.&#x20;Moreover,&#x20;novel&#x20;cage-based&#x20;3D&#x20;deformation&#x20;and&#x20;multi-threaded&#x20;particle&#x20;swarm&#x20;optimization&#x20;are&#x20;utilized&#x20;to&#x20;implement&#x20;real-time&#x20;registration.&#x20;We&#x20;evaluated&#x20;the&#x20;proposed&#x20;method&#x20;for&#x20;154&#x20;examinations&#x20;from&#x20;10&#x20;anonymous&#x20;patients&#x20;by&#x20;coverage&#x20;percentage,&#x20;comparing&#x20;the&#x20;average&#x20;distance&#x20;of&#x20;the&#x20;2D&#x20;extracted&#x20;center-line&#x20;with&#x20;that&#x20;of&#x20;the&#x20;registered&#x20;3D&#x20;center-line.&#x20;Results:&#x20;The&#x20;proposed&#x20;2D-3D&#x20;non-rigid&#x20;registration&#x20;method&#x20;achieved&#x20;an&#x20;average&#x20;distance&#x20;of&#x20;1.98&#x20;mm&#x20;with&#x20;a&#x20;0.54&#x20;s&#x20;computation&#x20;time.&#x20;Additionally,&#x20;in&#x20;aiming&#x20;to&#x20;reduce&#x20;the&#x20;uncertainty&#x20;of&#x20;XA&#x20;images,&#x20;we&#x20;used&#x20;the&#x20;proposed&#x20;method&#x20;to&#x20;retrospectively&#x20;visualize&#x20;the&#x20;connections&#x20;between&#x20;2D&#x20;vascular&#x20;segments&#x20;and&#x20;the&#x20;distal&#x20;part&#x20;of&#x20;occlusions.&#x20;Conclusions:&#x20;Ultimately,&#x20;the&#x20;proposed&#x20;2D&#x2F;3D&#x20;non-rigid&#x20;registration&#x20;method&#x20;can&#x20;successfully&#x20;register&#x20;the&#x20;3D&#x20;center-line&#x20;of&#x20;coronary&#x20;arteries&#x20;with&#x20;corresponding&#x20;2D&#x20;XA&#x20;images,&#x20;and&#x20;is&#x20;computationally&#x20;sufficient&#x20;for&#x20;online&#x20;usage.&#x20;Therefore,&#x20;this&#x20;method&#x20;can&#x20;improve&#x20;the&#x20;success&#x20;rate&#x20;of&#x20;such&#x20;procedures&#x20;as&#x20;a&#x20;percutaneous&#x20;coronary&#x20;intervention&#x20;and&#x20;provide&#x20;the&#x20;information&#x20;necessary&#x20;to&#x20;diagnose&#x20;cardiovascular&#x20;diseases&#x20;better.&#x20;(c)&#x20;2021&#x20;Elsevier&#x20;B.V.&#x20;All&#x20;rights&#x20;reserved.</dcvalue>
<dcvalue element="language" qualifier="none">English</dcvalue>
<dcvalue element="publisher" qualifier="none">ELSEVIER&#x20;IRELAND&#x20;LTD</dcvalue>
<dcvalue element="title" qualifier="none">Topological&#x20;recovery&#x20;for&#x20;non-rigid&#x20;2D&#x2F;3D&#x20;registration&#x20;of&#x20;coronary&#x20;artery&#x20;models</dcvalue>
<dcvalue element="type" qualifier="none">Article</dcvalue>
<dcvalue element="identifier" qualifier="doi">10.1016&#x2F;j.cmpb.2020.105922</dcvalue>
<dcvalue element="description" qualifier="journalClass">1</dcvalue>
<dcvalue element="identifier" qualifier="bibliographicCitation">COMPUTER&#x20;METHODS&#x20;AND&#x20;PROGRAMS&#x20;IN&#x20;BIOMEDICINE,&#x20;v.200</dcvalue>
<dcvalue element="citation" qualifier="title">COMPUTER&#x20;METHODS&#x20;AND&#x20;PROGRAMS&#x20;IN&#x20;BIOMEDICINE</dcvalue>
<dcvalue element="citation" qualifier="volume">200</dcvalue>
<dcvalue element="description" qualifier="journalRegisteredClass">scie</dcvalue>
<dcvalue element="description" qualifier="journalRegisteredClass">scopus</dcvalue>
<dcvalue element="identifier" qualifier="wosid">000623113400017</dcvalue>
<dcvalue element="identifier" qualifier="scopusid">2-s2.0-85099178520</dcvalue>
<dcvalue element="relation" qualifier="journalWebOfScienceCategory">Computer&#x20;Science,&#x20;Interdisciplinary&#x20;Applications</dcvalue>
<dcvalue element="relation" qualifier="journalWebOfScienceCategory">Computer&#x20;Science,&#x20;Theory&#x20;&amp;&#x20;Methods</dcvalue>
<dcvalue element="relation" qualifier="journalWebOfScienceCategory">Engineering,&#x20;Biomedical</dcvalue>
<dcvalue element="relation" qualifier="journalWebOfScienceCategory">Medical&#x20;Informatics</dcvalue>
<dcvalue element="relation" qualifier="journalResearchArea">Computer&#x20;Science</dcvalue>
<dcvalue element="relation" qualifier="journalResearchArea">Engineering</dcvalue>
<dcvalue element="relation" qualifier="journalResearchArea">Medical&#x20;Informatics</dcvalue>
<dcvalue element="type" qualifier="docType">Article</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Arteries</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Angiography</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Non-rigid&#x20;registration</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">2D-3D&#x20;registration</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Chronic&#x20;total&#x20;occlusion</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Deformable&#x20;models</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Particle&#x20;swarm&#x20;optimization</dcvalue>
</dublin_core>