<?xml version="1.0" encoding="utf-8" standalone="no"?>
<dublin_core schema="dc">
<dcvalue element="contributor" qualifier="author">Choi,&#x20;K</dcvalue>
<dcvalue element="contributor" qualifier="author">Kwon,&#x20;IC</dcvalue>
<dcvalue element="contributor" qualifier="author">Khang,&#x20;G</dcvalue>
<dcvalue element="contributor" qualifier="author">Rhee,&#x20;K</dcvalue>
<dcvalue element="contributor" qualifier="author">Lee,&#x20;YC</dcvalue>
<dcvalue element="date" qualifier="accessioned">2024-01-19T16:09:06Z</dcvalue>
<dcvalue element="date" qualifier="available">2024-01-19T16:09:06Z</dcvalue>
<dcvalue element="date" qualifier="created">2022-03-07</dcvalue>
<dcvalue element="date" qualifier="issued">2001-06</dcvalue>
<dcvalue element="identifier" qualifier="uri">https:&#x2F;&#x2F;pubs.kist.re.kr&#x2F;handle&#x2F;201004&#x2F;117926</dcvalue>
<dcvalue element="description" qualifier="abstract">In&#x20;this&#x20;study,&#x20;chitosan&#x20;was&#x20;coated&#x20;on&#x20;dental&#x20;implants&#x20;to&#x20;serve&#x20;as&#x20;a&#x20;periodontal&#x20;ligament-like&#x20;soft&#x20;membrane&#x20;and&#x20;the&#x20;biomechanical&#x20;functions&#x20;of&#x20;the&#x20;membrane&#x20;were&#x20;studied.&#x20;The&#x20;results&#x20;by&#x20;experiments&#x20;and&#x20;ITEM&#x20;analysis&#x20;showed:&#x20;1)&#x20;Initial&#x20;stability&#x20;of&#x20;the&#x20;dental&#x20;implant&#x20;significantly&#x20;increased&#x20;(35%)&#x20;when&#x20;it&#x20;was&#x20;coated&#x20;with&#x20;chitosan,&#x20;and&#x20;2)&#x20;the&#x20;coated&#x20;implants&#x20;showed&#x20;significantly&#x20;higher&#x20;impact&#x20;absorbing&#x20;capability,&#x20;more&#x20;even&#x20;stress&#x20;distribution,&#x20;and&#x20;lower&#x20;peak&#x20;stress&#x20;magnitude&#x20;in&#x20;bone&#x20;tissue&#x20;around&#x20;implant&#x20;under&#x20;impact&#x20;loading&#x20;than&#x20;uncoated&#x20;implants.</dcvalue>
<dcvalue element="language" qualifier="none">English</dcvalue>
<dcvalue element="publisher" qualifier="none">UNIV&#x20;ZAGREB</dcvalue>
<dcvalue element="title" qualifier="none">Biomechanical&#x20;study&#x20;on&#x20;the&#x20;periodontal&#x20;ligamen-like&#x20;artificial&#x20;membrane&#x20;around&#x20;dental&#x20;implant</dcvalue>
<dcvalue element="type" qualifier="none">Conference</dcvalue>
<dcvalue element="description" qualifier="journalClass">1</dcvalue>
<dcvalue element="identifier" qualifier="bibliographicCitation">9th&#x20;Mediterranean&#x20;Conference&#x20;on&#x20;Medical&#x20;and&#x20;Biological&#x20;Engineering&#x20;and&#x20;Computing,&#x20;pp.723&#x20;-&#x20;726</dcvalue>
<dcvalue element="citation" qualifier="title">9th&#x20;Mediterranean&#x20;Conference&#x20;on&#x20;Medical&#x20;and&#x20;Biological&#x20;Engineering&#x20;and&#x20;Computing</dcvalue>
<dcvalue element="citation" qualifier="startPage">723</dcvalue>
<dcvalue element="citation" qualifier="endPage">726</dcvalue>
<dcvalue element="citation" qualifier="conferencePlace">CT</dcvalue>
<dcvalue element="citation" qualifier="conferencePlace">PULA,&#x20;CROATIA</dcvalue>
<dcvalue element="citation" qualifier="conferenceDate">2001-06-12</dcvalue>
<dcvalue element="relation" qualifier="isPartOf">MEDICON&#x20;2001:&#x20;PROCEEDINGS&#x20;OF&#x20;THE&#x20;INTERNATIONAL&#x20;FEDERATION&#x20;FOR&#x20;MEDICAL&#x20;&amp;&#x20;BIOLOGICAL&#x20;ENGINEERING,&#x20;PTS&#x20;1&#x20;AND&#x20;2</dcvalue>
<dcvalue element="identifier" qualifier="wosid">000176065600202</dcvalue>
</dublin_core>
