<?xml version="1.0" encoding="utf-8" standalone="no"?>
<dublin_core schema="dc">
<dcvalue element="contributor" qualifier="author">Kang,&#x20;Sehong</dcvalue>
<dcvalue element="contributor" qualifier="author">Rachim,&#x20;Vega&#x20;Pradana</dcvalue>
<dcvalue element="contributor" qualifier="author">Baek,&#x20;Jin-Hyeok</dcvalue>
<dcvalue element="contributor" qualifier="author">Lee,&#x20;Seung&#x20;Yong</dcvalue>
<dcvalue element="contributor" qualifier="author">Park,&#x20;Sung-Min</dcvalue>
<dcvalue element="date" qualifier="accessioned">2024-01-19T17:01:56Z</dcvalue>
<dcvalue element="date" qualifier="available">2024-01-19T17:01:56Z</dcvalue>
<dcvalue element="date" qualifier="created">2021-09-04</dcvalue>
<dcvalue element="date" qualifier="issued">2020-08</dcvalue>
<dcvalue element="identifier" qualifier="issn">2169-3536</dcvalue>
<dcvalue element="identifier" qualifier="uri">https:&#x2F;&#x2F;pubs.kist.re.kr&#x2F;handle&#x2F;201004&#x2F;118307</dcvalue>
<dcvalue element="description" qualifier="abstract">A&#x20;flexible,&#x20;patch-type&#x20;strain&#x20;sensor&#x20;is&#x20;described&#x20;for&#x20;continuous&#x20;monitoring&#x20;of&#x20;pulse&#x20;waves.&#x20;The&#x20;proposed&#x20;sensor&#x20;exploits&#x20;the&#x20;piezo-resistivity&#x20;of&#x20;the&#x20;conductive&#x20;polymer,&#x20;polyaniline&#x20;(PANI),&#x20;to&#x20;detect&#x20;dynamic&#x20;volume&#x20;changes&#x20;in&#x20;blood&#x20;vessels&#x20;owing&#x20;to&#x20;pulse&#x20;waves.&#x20;The&#x20;proposed&#x20;PANI&#x20;film&#x20;was&#x20;fabricated&#x20;through&#x20;electrodeposition,&#x20;which&#x20;is&#x20;considered&#x20;as&#x20;a&#x20;suitable&#x20;low-cost&#x20;technique&#x20;for&#x20;mass&#x20;production&#x20;in&#x20;the&#x20;sensor&#x20;manufacturing&#x20;industry.&#x20;Thus,&#x20;it&#x20;is&#x20;prospective&#x20;for&#x20;a&#x20;disposable&#x20;wearable&#x20;sensing&#x20;system&#x20;solution&#x20;in&#x20;remote&#x20;healthcare&#x20;applications.&#x20;Besides,&#x20;a&#x20;flexible&#x20;sensor&#x20;packaging&#x20;can&#x20;be&#x20;achieved&#x20;by&#x20;laminating&#x20;the&#x20;PANI&#x20;films&#x20;and&#x20;an&#x20;ECOFLEX&#x20;elastomer&#x20;to&#x20;the&#x20;film&#x20;bandage.&#x20;The&#x20;proposed&#x20;PANI&#x20;sensor&#x20;has&#x20;high&#x20;sensitivity&#x20;(gauge&#x20;factor&#x20;of&#x20;74.28)&#x20;and&#x20;linearity&#x20;(R-2&#x20;=&#x20;0.99).&#x20;It&#x20;also&#x20;showed&#x20;a&#x20;high&#x20;correlation&#x20;with&#x20;commercially&#x20;available&#x20;photoplethysmography&#x20;(PPG)&#x20;sensor&#x20;with&#x20;the&#x20;small&#x20;bias&#x20;and&#x20;confidence&#x20;interval&#x20;to&#x20;the&#x20;PPG&#x20;sensor:&#x20;bias&#x20;&lt;&#x20;0.1%&#x20;and&#x20;confidence&#x20;interval&#x20;&lt;&#x20;3%&#x20;for&#x20;all&#x20;subjects.&#x20;Moreover,&#x20;the&#x20;proposed&#x20;PANI&#x20;sensor&#x20;was&#x20;tested&#x20;for&#x20;prospective&#x20;circulatory&#x20;system-related&#x20;applications&#x20;such&#x20;as&#x20;measuring&#x20;heart&#x20;rate,&#x20;stiffness&#x20;index,&#x20;and&#x20;pulse&#x20;transit&#x20;time.&#x20;Finally,&#x20;the&#x20;proposed&#x20;study&#x20;suggests&#x20;that&#x20;the&#x20;proposed&#x20;PANI&#x20;sensor&#x20;is&#x20;a&#x20;promising&#x20;candidate&#x20;for&#x20;continuous,&#x20;long-term,&#x20;unobtrusive&#x20;pulse&#x20;wave&#x20;monitoring,&#x20;which&#x20;can&#x20;provide&#x20;real-time&#x20;insights&#x20;into&#x20;an&#x20;individual&amp;apos;s&#x20;health&#x20;status.</dcvalue>
<dcvalue element="language" qualifier="none">English</dcvalue>
<dcvalue element="publisher" qualifier="none">IEEE-INST&#x20;ELECTRICAL&#x20;ELECTRONICS&#x20;ENGINEERS&#x20;INC</dcvalue>
<dcvalue element="subject" qualifier="none">ARTERIAL&#x20;STIFFNESS</dcvalue>
<dcvalue element="subject" qualifier="none">TRANSIT-TIME</dcvalue>
<dcvalue element="subject" qualifier="none">PRESSURE</dcvalue>
<dcvalue element="subject" qualifier="none">COMPOSITE</dcvalue>
<dcvalue element="subject" qualifier="none">FORM</dcvalue>
<dcvalue element="title" qualifier="none">A&#x20;Flexible&#x20;Patch-Type&#x20;Strain&#x20;Sensor&#x20;Based&#x20;on&#x20;Polyaniline&#x20;for&#x20;Continuous&#x20;Monitoring&#x20;of&#x20;Pulse&#x20;Waves</dcvalue>
<dcvalue element="type" qualifier="none">Article</dcvalue>
<dcvalue element="identifier" qualifier="doi">10.1109&#x2F;ACCESS.2020.3017218</dcvalue>
<dcvalue element="description" qualifier="journalClass">1</dcvalue>
<dcvalue element="identifier" qualifier="bibliographicCitation">IEEE&#x20;ACCESS,&#x20;v.8,&#x20;pp.152105&#x20;-&#x20;152115</dcvalue>
<dcvalue element="citation" qualifier="title">IEEE&#x20;ACCESS</dcvalue>
<dcvalue element="citation" qualifier="volume">8</dcvalue>
<dcvalue element="citation" qualifier="startPage">152105</dcvalue>
<dcvalue element="citation" qualifier="endPage">152115</dcvalue>
<dcvalue element="description" qualifier="journalRegisteredClass">scie</dcvalue>
<dcvalue element="description" qualifier="journalRegisteredClass">scopus</dcvalue>
<dcvalue element="identifier" qualifier="wosid">000565610900001</dcvalue>
<dcvalue element="identifier" qualifier="scopusid">2-s2.0-85090783250</dcvalue>
<dcvalue element="relation" qualifier="journalWebOfScienceCategory">Computer&#x20;Science,&#x20;Information&#x20;Systems</dcvalue>
<dcvalue element="relation" qualifier="journalWebOfScienceCategory">Engineering,&#x20;Electrical&#x20;&amp;&#x20;Electronic</dcvalue>
<dcvalue element="relation" qualifier="journalWebOfScienceCategory">Telecommunications</dcvalue>
<dcvalue element="relation" qualifier="journalResearchArea">Computer&#x20;Science</dcvalue>
<dcvalue element="relation" qualifier="journalResearchArea">Engineering</dcvalue>
<dcvalue element="relation" qualifier="journalResearchArea">Telecommunications</dcvalue>
<dcvalue element="type" qualifier="docType">Article</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">ARTERIAL&#x20;STIFFNESS</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">TRANSIT-TIME</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">PRESSURE</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">COMPOSITE</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">FORM</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Monitoring</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Biomedical&#x20;monitoring</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Electrodes</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Skin</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Capacitive&#x20;sensors</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Pulse&#x20;measurements</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Polymers</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Conductive&#x20;polymer</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">flexible&#x20;sensor</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">healthcare&#x20;device</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">health&#x20;monitoring</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">piezoresistive&#x20;sensor</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">wearable&#x20;sensor</dcvalue>
</dublin_core>
