<?xml version="1.0" encoding="utf-8" standalone="no"?>
<dublin_core schema="dc">
<dcvalue element="contributor" qualifier="author">Song,&#x20;Kang-Il</dcvalue>
<dcvalue element="contributor" qualifier="author">Park,&#x20;Sunghee&#x20;Estelle</dcvalue>
<dcvalue element="contributor" qualifier="author">Hwang,&#x20;Dosik</dcvalue>
<dcvalue element="contributor" qualifier="author">Youn,&#x20;Inchan</dcvalue>
<dcvalue element="date" qualifier="accessioned">2024-01-19T20:33:34Z</dcvalue>
<dcvalue element="date" qualifier="available">2024-01-19T20:33:34Z</dcvalue>
<dcvalue element="date" qualifier="created">2021-09-02</dcvalue>
<dcvalue element="date" qualifier="issued">2019-03</dcvalue>
<dcvalue element="identifier" qualifier="issn">0090-6964</dcvalue>
<dcvalue element="identifier" qualifier="uri">https:&#x2F;&#x2F;pubs.kist.re.kr&#x2F;handle&#x2F;201004&#x2F;120299</dcvalue>
<dcvalue element="description" qualifier="abstract">Cuff&#x20;electrodes&#x20;have&#x20;been&#x20;introduced&#x20;into&#x20;functional&#x20;neuromuscular&#x20;stimulation&#x20;systems&#x20;to&#x20;either&#x20;obtain&#x20;neural&#x20;signals&#x20;or&#x20;elicit&#x20;limb&#x20;movements.&#x20;Multiple&#x20;electrodes&#x20;must&#x20;be&#x20;implanted&#x20;to&#x20;construct&#x20;a&#x20;feedback&#x20;control&#x20;loop,&#x20;including&#x20;one&#x20;electrode&#x20;for&#x20;acquisition&#x20;and&#x20;another&#x20;for&#x20;stimulation.&#x20;Existing&#x20;approaches&#x20;require&#x20;too&#x20;much&#x20;space&#x20;inside&#x20;the&#x20;body&#x20;and&#x20;a&#x20;complicated&#x20;surgical&#x20;procedure.&#x20;This&#x20;paper&#x20;proposes&#x20;a&#x20;novel&#x20;neural&#x20;interface&#x20;method&#x20;that&#x20;uses&#x20;a&#x20;single&#x20;cuff&#x20;electrode&#x20;with&#x20;multichannel&#x20;capability&#x20;to&#x20;simultaneously&#x20;acquire&#x20;multichannel&#x20;recordings&#x20;and&#x20;induce&#x20;electrical&#x20;stimulation&#x20;at&#x20;the&#x20;proximal&#x20;nerve&#x20;trunk&#x20;of&#x20;the&#x20;sciatic&#x20;nerve.&#x20;Recordings&#x20;and&#x20;stimulation&#x20;are&#x20;conducted&#x20;in&#x20;a&#x20;time-shared&#x20;manner&#x20;using&#x20;a&#x20;path&#x20;controller.&#x20;Using&#x20;the&#x20;proposed&#x20;method,&#x20;joint&#x20;positions&#x20;are&#x20;estimated&#x20;from&#x20;multichannel&#x20;recorded&#x20;neural&#x20;signals&#x20;during&#x20;electrical&#x20;stimulation&#x20;as&#x20;neural&#x20;signals&#x20;are&#x20;continuously&#x20;recorded.&#x20;In&#x20;addition,&#x20;the&#x20;proposed&#x20;system&#x20;is&#x20;shown&#x20;to&#x20;be&#x20;suitable&#x20;for&#x20;controlling&#x20;joint&#x20;position.&#x20;The&#x20;proposed&#x20;neural&#x20;interface&#x20;method&#x20;overcomes&#x20;the&#x20;spatial&#x20;limitations&#x20;of&#x20;electrode&#x20;implantation&#x20;and&#x20;thus&#x20;offers&#x20;a&#x20;new&#x20;approach&#x20;to&#x20;developing&#x20;compact&#x20;neural&#x20;interface&#x20;systems.</dcvalue>
<dcvalue element="language" qualifier="none">English</dcvalue>
<dcvalue element="publisher" qualifier="none">SPRINGER</dcvalue>
<dcvalue element="subject" qualifier="none">CLOSED-LOOP&#x20;CONTROL</dcvalue>
<dcvalue element="subject" qualifier="none">RABBIT&#x20;ANKLE&#x20;JOINT</dcvalue>
<dcvalue element="subject" qualifier="none">ELECTRICAL-STIMULATION</dcvalue>
<dcvalue element="subject" qualifier="none">MOTION&#x20;CONTROL</dcvalue>
<dcvalue element="subject" qualifier="none">NERVE</dcvalue>
<dcvalue element="subject" qualifier="none">FEEDBACK</dcvalue>
<dcvalue element="subject" qualifier="none">SIGNALS</dcvalue>
<dcvalue element="subject" qualifier="none">INFORMATION</dcvalue>
<dcvalue element="subject" qualifier="none">RECORDINGS</dcvalue>
<dcvalue element="subject" qualifier="none">COMMAND</dcvalue>
<dcvalue element="title" qualifier="none">Compact&#x20;Neural&#x20;Interface&#x20;Using&#x20;a&#x20;Single&#x20;Multichannel&#x20;Cuff&#x20;Electrode&#x20;for&#x20;a&#x20;Functional&#x20;Neuromuscular&#x20;Stimulation&#x20;System</dcvalue>
<dcvalue element="type" qualifier="none">Article</dcvalue>
<dcvalue element="identifier" qualifier="doi">10.1007&#x2F;s10439-018-02181-1</dcvalue>
<dcvalue element="description" qualifier="journalClass">1</dcvalue>
<dcvalue element="identifier" qualifier="bibliographicCitation">ANNALS&#x20;OF&#x20;BIOMEDICAL&#x20;ENGINEERING,&#x20;v.47,&#x20;no.3,&#x20;pp.754&#x20;-&#x20;766</dcvalue>
<dcvalue element="citation" qualifier="title">ANNALS&#x20;OF&#x20;BIOMEDICAL&#x20;ENGINEERING</dcvalue>
<dcvalue element="citation" qualifier="volume">47</dcvalue>
<dcvalue element="citation" qualifier="number">3</dcvalue>
<dcvalue element="citation" qualifier="startPage">754</dcvalue>
<dcvalue element="citation" qualifier="endPage">766</dcvalue>
<dcvalue element="description" qualifier="journalRegisteredClass">scie</dcvalue>
<dcvalue element="description" qualifier="journalRegisteredClass">scopus</dcvalue>
<dcvalue element="identifier" qualifier="wosid">000459143900008</dcvalue>
<dcvalue element="identifier" qualifier="scopusid">2-s2.0-85058702930</dcvalue>
<dcvalue element="relation" qualifier="journalWebOfScienceCategory">Engineering,&#x20;Biomedical</dcvalue>
<dcvalue element="relation" qualifier="journalResearchArea">Engineering</dcvalue>
<dcvalue element="type" qualifier="docType">Article</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">CLOSED-LOOP&#x20;CONTROL</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">RABBIT&#x20;ANKLE&#x20;JOINT</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">ELECTRICAL-STIMULATION</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">MOTION&#x20;CONTROL</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">NERVE</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">FEEDBACK</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">SIGNALS</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">INFORMATION</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">RECORDINGS</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">COMMAND</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Muscle&#x20;afferent</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Blind&#x20;source&#x20;separation</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Artificial&#x20;neural&#x20;network</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Closed-loop&#x20;system</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Joint&#x20;position&#x20;control</dcvalue>
</dublin_core>
