<?xml version="1.0" encoding="utf-8" standalone="no"?>
<dublin_core schema="dc">
<dcvalue element="contributor" qualifier="author">Park,&#x20;Joo&#x20;Hoon</dcvalue>
<dcvalue element="contributor" qualifier="author">Shin,&#x20;Youhwan</dcvalue>
<dcvalue element="contributor" qualifier="author">Chung,&#x20;Jin&#x20;Taek</dcvalue>
<dcvalue element="date" qualifier="accessioned">2024-01-20T00:01:34Z</dcvalue>
<dcvalue element="date" qualifier="available">2024-01-20T00:01:34Z</dcvalue>
<dcvalue element="date" qualifier="created">2021-09-03</dcvalue>
<dcvalue element="date" qualifier="issued">2017-12</dcvalue>
<dcvalue element="identifier" qualifier="issn">1996-1073</dcvalue>
<dcvalue element="identifier" qualifier="uri">https:&#x2F;&#x2F;pubs.kist.re.kr&#x2F;handle&#x2F;201004&#x2F;121970</dcvalue>
<dcvalue element="description" qualifier="abstract">As&#x20;environmental&#x20;regulations&#x20;to&#x20;stall&#x20;global&#x20;warming&#x20;are&#x20;strengthened&#x20;around&#x20;the&#x20;world,&#x20;studies&#x20;using&#x20;newly&#x20;developed&#x20;low&#x20;global&#x20;warming&#x20;potential&#x20;(GWP)&#x20;alternative&#x20;refrigerants&#x20;are&#x20;increasing.&#x20;In&#x20;this&#x20;study,&#x20;substitute&#x20;refrigerants,&#x20;R-1234ze&#x20;(E)&#x20;and&#x20;R-1233zd&#x20;(E),&#x20;were&#x20;used&#x20;in&#x20;the&#x20;centrifugal&#x20;compressor&#x20;of&#x20;an&#x20;R-134a&#x20;2-stage&#x20;centrifugal&#x20;chiller&#x20;with&#x20;a&#x20;fixed&#x20;rotational&#x20;speed.&#x20;Performance&#x20;predictions&#x20;and&#x20;thermodynamic&#x20;analyses&#x20;of&#x20;the&#x20;centrifugal&#x20;compressor&#x20;for&#x20;drop-in&#x20;testing&#x20;were&#x20;performed.&#x20;A&#x20;performance&#x20;prediction&#x20;method&#x20;based&#x20;on&#x20;the&#x20;existing&#x20;ASME&#x20;PTC-10&#x20;performance&#x20;test&#x20;code&#x20;was&#x20;proposed.&#x20;The&#x20;proposed&#x20;method&#x20;yielded&#x20;the&#x20;expected&#x20;operating&#x20;area&#x20;and&#x20;operating&#x20;point&#x20;of&#x20;the&#x20;centrifugal&#x20;compressor&#x20;with&#x20;alternative&#x20;refrigerants.&#x20;The&#x20;thermodynamic&#x20;performance&#x20;of&#x20;the&#x20;first&#x20;and&#x20;second&#x20;stages&#x20;of&#x20;the&#x20;centrifugal&#x20;compressor&#x20;was&#x20;calculated&#x20;as&#x20;the&#x20;polytropic&#x20;state.&#x20;To&#x20;verify&#x20;the&#x20;suitability&#x20;of&#x20;the&#x20;proposed&#x20;method,&#x20;the&#x20;drop-in&#x20;test&#x20;results&#x20;of&#x20;the&#x20;two&#x20;alternative&#x20;refrigerants&#x20;were&#x20;compared.&#x20;The&#x20;predicted&#x20;operating&#x20;range&#x20;based&#x20;on&#x20;the&#x20;permissible&#x20;deviation&#x20;of&#x20;ASME&#x20;PTC-10&#x20;confirmed&#x20;that&#x20;the&#x20;temperature&#x20;difference&#x20;was&#x20;very&#x20;small&#x20;at&#x20;the&#x20;same&#x20;efficiency.&#x20;Because&#x20;the&#x20;drop-in&#x20;test&#x20;of&#x20;R-1234ze&#x20;(E)&#x20;was&#x20;performed&#x20;within&#x20;the&#x20;expected&#x20;operating&#x20;range,&#x20;the&#x20;centrifugal&#x20;compressor&#x20;using&#x20;R-1234ze&#x20;(E)&#x20;is&#x20;considered&#x20;well&#x20;predicted.&#x20;However,&#x20;the&#x20;predictions&#x20;of&#x20;the&#x20;operating&#x20;point&#x20;and&#x20;operating&#x20;range&#x20;of&#x20;R-1233zd&#x20;(E)&#x20;were&#x20;lower&#x20;than&#x20;those&#x20;of&#x20;the&#x20;drop-in&#x20;test.&#x20;The&#x20;proposed&#x20;performance&#x20;prediction&#x20;method&#x20;will&#x20;assist&#x20;in&#x20;understanding&#x20;thermodynamic&#x20;performance&#x20;at&#x20;the&#x20;expected&#x20;operating&#x20;point&#x20;and&#x20;operating&#x20;area&#x20;of&#x20;a&#x20;centrifugal&#x20;compressor&#x20;using&#x20;alternative&#x20;gases&#x20;based&#x20;on&#x20;limited&#x20;design&#x20;and&#x20;structure&#x20;information.</dcvalue>
<dcvalue element="language" qualifier="none">English</dcvalue>
<dcvalue element="publisher" qualifier="none">MDPI</dcvalue>
<dcvalue element="subject" qualifier="none">R1234ZE(E)</dcvalue>
<dcvalue element="subject" qualifier="none">R1234YF</dcvalue>
<dcvalue element="subject" qualifier="none">R134A</dcvalue>
<dcvalue element="title" qualifier="none">Performance&#x20;Prediction&#x20;of&#x20;Centrifugal&#x20;Compressor&#x20;for&#x20;Drop-In&#x20;Testing&#x20;Using&#x20;Low&#x20;Global&#x20;Warming&#x20;Potential&#x20;Alternative&#x20;Refrigerants&#x20;and&#x20;Performance&#x20;Test&#x20;Codes</dcvalue>
<dcvalue element="type" qualifier="none">Article</dcvalue>
<dcvalue element="identifier" qualifier="doi">10.3390&#x2F;en10122043</dcvalue>
<dcvalue element="description" qualifier="journalClass">1</dcvalue>
<dcvalue element="identifier" qualifier="bibliographicCitation">ENERGIES,&#x20;v.10,&#x20;no.12</dcvalue>
<dcvalue element="citation" qualifier="title">ENERGIES</dcvalue>
<dcvalue element="citation" qualifier="volume">10</dcvalue>
<dcvalue element="citation" qualifier="number">12</dcvalue>
<dcvalue element="description" qualifier="journalRegisteredClass">scie</dcvalue>
<dcvalue element="description" qualifier="journalRegisteredClass">scopus</dcvalue>
<dcvalue element="identifier" qualifier="wosid">000423156900114</dcvalue>
<dcvalue element="identifier" qualifier="scopusid">2-s2.0-85044395561</dcvalue>
<dcvalue element="relation" qualifier="journalWebOfScienceCategory">Energy&#x20;&amp;&#x20;Fuels</dcvalue>
<dcvalue element="relation" qualifier="journalResearchArea">Energy&#x20;&amp;&#x20;Fuels</dcvalue>
<dcvalue element="type" qualifier="docType">Article</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">R1234ZE(E)</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">R1234YF</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">R134A</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">operating&#x20;range</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">operating&#x20;point</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">centrifugal&#x20;compressor</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">low-GWP&#x20;alternative&#x20;refrigerant</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">R-1234ze&#x20;(E)</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">R-1233zd&#x20;(E)</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">drop-in&#x20;test</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">performance&#x20;test&#x20;code</dcvalue>
</dublin_core>
