<dcvalue element="description" qualifier="abstract">Aiming&#x20;for&#x20;improvement&#x20;of&#x20;the&#x20;cooling&#x20;performance,&#x20;the&#x20;hybrid&#x20;desiccant&#x20;cooling&#x20;system&#x20;(HDCS)&#x20;is&#x20;investigated&#x20;and&#x20;compared&#x20;with&#x20;a&#x20;reference&#x20;desiccant&#x20;cooling&#x20;system&#x20;(RDCS).&#x20;By&#x20;replacing&#x20;a&#x20;sensible&#x20;wheel&#x20;of&#x20;the&#x20;RDCS&#x20;with&#x20;a&#x20;heat&#x20;pump,&#x20;the&#x20;HDCS&#x20;is&#x20;expected&#x20;to&#x20;increase&#x20;the&#x20;energy&#x20;efficiency&#x20;as&#x20;well&#x20;as&#x20;to&#x20;improve&#x20;the&#x20;system&#x20;compactness.&#x20;The&#x20;cooling&#x20;cycle&#x20;is&#x20;simulated&#x20;and&#x20;its&#x20;results&#x20;are&#x20;compared&#x20;with&#x20;those&#x20;of&#x20;the&#x20;RDCS.&#x20;The&#x20;analysis&#x20;showed&#x20;that&#x20;specific&#x20;cooling&#x20;power&#x20;of&#x20;the&#x20;HDCS&#x20;increases&#x20;from&#x20;that&#x20;of&#x20;RDCS,&#x20;promising&#x20;the&#x20;miniaturization&#x20;of&#x20;the&#x20;system.&#x20;Also,&#x20;COP&#x20;of&#x20;HDCS&#x20;was&#x20;found&#x20;to&#x20;overtake&#x20;the&#x20;COP&#x20;of&#x20;RDCS&#x20;in&#x20;a&#x20;particular&#x20;range&#x20;of&#x20;heat&#x20;pump&#x20;capacity.&#x20;For&#x20;analysis&#x20;of&#x20;total&#x20;energy&#x20;consumption,&#x20;a&#x20;new&#x20;parameter,&#x20;R,&#x20;the&#x20;ratio&#x20;of&#x20;the&#x20;primary&#x20;energy&#x20;factor&#x20;of&#x20;electrical&#x20;energy&#x20;to&#x20;the&#x20;primary&#x20;energy&#x20;factor&#x20;of&#x20;thermal&#x20;energy&#x20;was&#x20;introduced.&#x20;In&#x20;the&#x20;range&#x20;of&#x20;R&#x20;(=5-10)&#x20;such&#x20;as&#x20;from&#x20;the&#x20;CHP&#x20;plants,&#x20;the&#x20;optimal&#x20;heat&#x20;pump&#x20;capacity&#x20;was&#x20;estimated&#x20;when&#x20;the&#x20;heat&#x20;pump&#x20;occupies&#x20;30-40%&#x20;of&#x20;the&#x20;total&#x20;cooling&#x20;output&#x20;of&#x20;the&#x20;HDCS.&#x20;With&#x20;the&#x20;optimal&#x20;configuration,&#x20;the&#x20;total&#x20;energy&#x20;consumption&#x20;of&#x20;HDCS&#x20;reduces&#x20;by&#x20;20-30%&#x20;and&#x20;the&#x20;cooling&#x20;capacity&#x20;of&#x20;HDCS&#x20;increases&#x20;by&#x20;40-60%,&#x20;compared&#x20;to&#x20;RDCS.&#x20;(C)&#x20;2016&#x20;Elsevier&#x20;Ltd.&#x20;All&#x20;rights&#x20;reserved.</dcvalue>
<dcvalue element="language" qualifier="none">English</dcvalue>
<dcvalue element="publisher" qualifier="none">PERGAMON-ELSEVIER&#x20;SCIENCE&#x20;LTD</dcvalue>
<dcvalue element="subject" qualifier="none">AIR-CONDITIONING&#x20;SYSTEM</dcvalue>
<dcvalue element="subject" qualifier="none">ENERGY&#x20;PERFORMANCE</dcvalue>
<dcvalue element="subject" qualifier="none">WHEEL</dcvalue>
<dcvalue element="subject" qualifier="none">HOT</dcvalue>
<dcvalue element="subject" qualifier="none">REFRIGERATION</dcvalue>
<dcvalue element="subject" qualifier="none">OPTIMIZATION</dcvalue>
<dcvalue element="title" qualifier="none">In-depth&#x20;analysis&#x20;of&#x20;the&#x20;performance&#x20;of&#x20;hybrid&#x20;desiccant&#x20;cooling&#x20;system&#x20;incorporated&#x20;with&#x20;an&#x20;electric&#x20;heat&#x20;pump</dcvalue>
<dcvalue element="type" qualifier="none">Article</dcvalue>
<dcvalue element="identifier" qualifier="doi">10.1016&#x2F;j.energy.2016.12.007</dcvalue>
<dcvalue element="description" qualifier="journalClass">1</dcvalue>
<dcvalue element="identifier" qualifier="bibliographicCitation">ENERGY,&#x20;v.118,&#x20;pp.324&#x20;-&#x20;332</dcvalue>
<dcvalue element="citation" qualifier="title">ENERGY</dcvalue>
<dcvalue element="citation" qualifier="volume">118</dcvalue>
<dcvalue element="citation" qualifier="startPage">324</dcvalue>
<dcvalue element="citation" qualifier="endPage">332</dcvalue>
<dcvalue element="description" qualifier="journalRegisteredClass">scie</dcvalue>
<dcvalue element="description" qualifier="journalRegisteredClass">scopus</dcvalue>
<dcvalue element="identifier" qualifier="wosid">000395048900029</dcvalue>
<dcvalue element="relation" qualifier="journalWebOfScienceCategory">Thermodynamics</dcvalue>
<dcvalue element="relation" qualifier="journalWebOfScienceCategory">Energy&#x20;&amp;&#x20;Fuels</dcvalue>
<dcvalue element="relation" qualifier="journalResearchArea">Thermodynamics</dcvalue>
<dcvalue element="relation" qualifier="journalResearchArea">Energy&#x20;&amp;&#x20;Fuels</dcvalue>
<dcvalue element="type" qualifier="docType">Article</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">AIR-CONDITIONING&#x20;SYSTEM</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">ENERGY&#x20;PERFORMANCE</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">WHEEL</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">HOT</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">REFRIGERATION</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">OPTIMIZATION</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Hybrid&#x20;desiccant&#x20;cooling&#x20;system</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Heat&#x20;pump</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Sensible&#x20;heat&#x20;wheel</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Compressor&#x20;capacity</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Primary&#x20;energy&#x20;consumption</dcvalue>