<?xml version="1.0" encoding="utf-8" standalone="no"?>
<dublin_core schema="dc">
<dcvalue element="contributor" qualifier="author">Lee,&#x20;Ga-Yeon</dcvalue>
<dcvalue element="contributor" qualifier="author">Chang,&#x20;Young&#x20;Wook</dcvalue>
<dcvalue element="contributor" qualifier="author">Ko,&#x20;Hyuk</dcvalue>
<dcvalue element="contributor" qualifier="author">Kang,&#x20;Min-Jung</dcvalue>
<dcvalue element="contributor" qualifier="author">Pyun,&#x20;Jae-Chul</dcvalue>
<dcvalue element="date" qualifier="accessioned">2024-01-20T04:00:20Z</dcvalue>
<dcvalue element="date" qualifier="available">2024-01-20T04:00:20Z</dcvalue>
<dcvalue element="date" qualifier="created">2021-09-04</dcvalue>
<dcvalue element="date" qualifier="issued">2016-07-20</dcvalue>
<dcvalue element="identifier" qualifier="issn">0003-2670</dcvalue>
<dcvalue element="identifier" qualifier="uri">https:&#x2F;&#x2F;pubs.kist.re.kr&#x2F;handle&#x2F;201004&#x2F;123865</dcvalue>
<dcvalue element="description" qualifier="abstract">A&#x20;band-type&#x20;microelectrode&#x20;was&#x20;made&#x20;using&#x20;a&#x20;parylene-N&#x20;film&#x20;as&#x20;a&#x20;passivation&#x20;layer.&#x20;A&#x20;circular-type,&#x20;mm-scale&#x20;electrode&#x20;with&#x20;the&#x20;same&#x20;diameter&#x20;as&#x20;the&#x20;band-type&#x20;microelectrode&#x20;was&#x20;also&#x20;made&#x20;with&#x20;an&#x20;electrode&#x20;area&#x20;that&#x20;was&#x20;5000&#x20;times&#x20;larger&#x20;than&#x20;the&#x20;band-type&#x20;microelectrode.&#x20;By&#x20;comparing&#x20;the&#x20;amperometric&#x20;signals&#x20;of&#x20;3,5,3&amp;apos;,5&amp;apos;-tetramethylbenzidine&#x20;(TMB)&#x20;samples&#x20;at&#x20;different&#x20;optical&#x20;density&#x20;(OD)&#x20;values,&#x20;the&#x20;band-type&#x20;microelectrode&#x20;was&#x20;determined&#x20;to&#x20;be&#x20;9&#x20;times&#x20;more&#x20;sensitive&#x20;than&#x20;the&#x20;circular-type&#x20;electrode.&#x20;The&#x20;properties&#x20;of&#x20;the&#x20;circular-type&#x20;and&#x20;the&#x20;band-type&#x20;electrodes&#x20;(e.g.,&#x20;the&#x20;shape&#x20;of&#x20;their&#x20;cyclic&#x20;voltammograms,&#x20;the&#x20;type&#x20;of&#x20;diffusion&#x20;layer&#x20;used,&#x20;and&#x20;the&#x20;diffusion&#x20;layer&#x20;thickness&#x20;per&#x20;unit&#x20;electrode&#x20;area)&#x20;were&#x20;characterized&#x20;according&#x20;to&#x20;their&#x20;electrode&#x20;area&#x20;using&#x20;the&#x20;COMSOL&#x20;Multiphysics&#x20;software.&#x20;From&#x20;these&#x20;simulations,&#x20;the&#x20;band-type&#x20;electrode&#x20;was&#x20;estimated&#x20;to&#x20;have&#x20;the&#x20;conventional&#x20;microelectrode&#x20;properties,&#x20;even&#x20;when&#x20;the&#x20;electrode&#x20;area&#x20;was&#x20;100&#x20;times&#x20;larger&#x20;than&#x20;a&#x20;conventional&#x20;circular-type&#x20;electrode.&#x20;These&#x20;results&#x20;show&#x20;that&#x20;both&#x20;the&#x20;geometry&#x20;and&#x20;the&#x20;area&#x20;of&#x20;an&#x20;electrode&#x20;can&#x20;influence&#x20;the&#x20;properties&#x20;of&#x20;the&#x20;electrode.&#x20;Finally,&#x20;amperometric&#x20;analysis&#x20;based&#x20;on&#x20;a&#x20;band-type&#x20;electrode&#x20;was&#x20;applied&#x20;to&#x20;commercial&#x20;ELISA&#x20;kits&#x20;to&#x20;analyze&#x20;human&#x20;hepatitis&#x20;B&#x20;surface&#x20;antigen&#x20;(hHBsAg)&#x20;and&#x20;human&#x20;immunodeficiency&#x20;virus&#x20;(HIV)&#x20;antibodies.&#x20;(C)&#x20;2016&#x20;Elsevier&#x20;B.V.&#x20;All&#x20;rights&#x20;reserved.</dcvalue>
<dcvalue element="language" qualifier="none">English</dcvalue>
<dcvalue element="publisher" qualifier="none">ELSEVIER</dcvalue>
<dcvalue element="subject" qualifier="none">SPR&#x20;BIOSENSOR</dcvalue>
<dcvalue element="subject" qualifier="none">PARYLENE</dcvalue>
<dcvalue element="subject" qualifier="none">ELECTRODE</dcvalue>
<dcvalue element="subject" qualifier="none">SENSOR</dcvalue>
<dcvalue element="subject" qualifier="none">LAYER</dcvalue>
<dcvalue element="subject" qualifier="none">FILM</dcvalue>
<dcvalue element="title" qualifier="none">Band-type&#x20;microelectrodes&#x20;for&#x20;amperometric&#x20;immunoassays</dcvalue>
<dcvalue element="type" qualifier="none">Article</dcvalue>
<dcvalue element="identifier" qualifier="doi">10.1016&#x2F;j.aca.2016.05.009</dcvalue>
<dcvalue element="description" qualifier="journalClass">1</dcvalue>
<dcvalue element="identifier" qualifier="bibliographicCitation">ANALYTICA&#x20;CHIMICA&#x20;ACTA,&#x20;v.928,&#x20;pp.39&#x20;-&#x20;48</dcvalue>
<dcvalue element="citation" qualifier="title">ANALYTICA&#x20;CHIMICA&#x20;ACTA</dcvalue>
<dcvalue element="citation" qualifier="volume">928</dcvalue>
<dcvalue element="citation" qualifier="startPage">39</dcvalue>
<dcvalue element="citation" qualifier="endPage">48</dcvalue>
<dcvalue element="description" qualifier="journalRegisteredClass">scie</dcvalue>
<dcvalue element="description" qualifier="journalRegisteredClass">scopus</dcvalue>
<dcvalue element="identifier" qualifier="wosid">000376656700004</dcvalue>
<dcvalue element="identifier" qualifier="scopusid">2-s2.0-84969522973</dcvalue>
<dcvalue element="relation" qualifier="journalWebOfScienceCategory">Chemistry,&#x20;Analytical</dcvalue>
<dcvalue element="relation" qualifier="journalResearchArea">Chemistry</dcvalue>
<dcvalue element="type" qualifier="docType">Article</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">SPR&#x20;BIOSENSOR</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">PARYLENE</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">ELECTRODE</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">SENSOR</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">LAYER</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">FILM</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Microelectrode</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Band-type</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Parylene</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Amperometry</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Simulation</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Immunoassay</dcvalue>
</dublin_core>
