<?xml version="1.0" encoding="utf-8" standalone="no"?>
<dublin_core schema="dc">
<dcvalue element="contributor" qualifier="author">Kim,&#x20;Yong&#x20;Woo</dcvalue>
<dcvalue element="contributor" qualifier="author">Kim,&#x20;Mi&#x20;Jeung</dcvalue>
<dcvalue element="contributor" qualifier="author">Park,&#x20;Ki&#x20;Ho</dcvalue>
<dcvalue element="contributor" qualifier="author">Jeoung,&#x20;Jin&#x20;Wook</dcvalue>
<dcvalue element="contributor" qualifier="author">Kim,&#x20;Seok&#x20;Hwan</dcvalue>
<dcvalue element="contributor" qualifier="author">Jang,&#x20;Cheol&#x20;In</dcvalue>
<dcvalue element="contributor" qualifier="author">Lee,&#x20;Soo&#x20;Hyun</dcvalue>
<dcvalue element="contributor" qualifier="author">Kim,&#x20;Jae&#x20;Hun</dcvalue>
<dcvalue element="contributor" qualifier="author">Lee,&#x20;Seok</dcvalue>
<dcvalue element="contributor" qualifier="author">Kang,&#x20;Ji&#x20;Yoon</dcvalue>
<dcvalue element="date" qualifier="accessioned">2024-01-20T05:32:30Z</dcvalue>
<dcvalue element="date" qualifier="available">2024-01-20T05:32:30Z</dcvalue>
<dcvalue element="date" qualifier="created">2021-09-03</dcvalue>
<dcvalue element="date" qualifier="issued">2015-12</dcvalue>
<dcvalue element="identifier" qualifier="issn">1442-6404</dcvalue>
<dcvalue element="identifier" qualifier="uri">https:&#x2F;&#x2F;pubs.kist.re.kr&#x2F;handle&#x2F;201004&#x2F;124703</dcvalue>
<dcvalue element="description" qualifier="abstract">Background:&#x20;This&#x20;study&#x20;aims&#x20;to&#x20;validate&#x20;the&#x20;performance&#x20;and&#x20;biocompatibility&#x20;of&#x20;an&#x20;implantable&#x20;inductive-type&#x20;sensor&#x20;for&#x20;continuous&#x20;monitoring&#x20;of&#x20;intraocular&#x20;pressure&#x20;(IOP)&#x20;Methods:&#x20;The&#x20;sensor&#x20;is&#x20;composed&#x20;of&#x20;a&#x20;top&#x20;layer&#x20;integrated&#x20;with&#x20;an&#x20;inductor&#x20;and&#x20;capacitor&#x20;circuit,&#x20;and&#x20;a&#x20;bottom&#x20;layer&#x20;integrated&#x20;with&#x20;ferrite.&#x20;With&#x20;IOP&#x20;change,&#x20;the&#x20;sensor&amp;apos;s&#x20;bottom&#x20;layer&#x20;is&#x20;mechanically&#x20;deflected,&#x20;which&#x20;changes&#x20;the&#x20;distance&#x20;between&#x20;the&#x20;bottom-layer&#x20;ferrite&#x20;and&#x20;top-layer&#x20;inductor,&#x20;resulting&#x20;in&#x20;an&#x20;alteration&#x20;of&#x20;inductance&#x20;magnitude&#x20;and&#x20;the&#x20;resonant&#x20;frequency&#x20;(RF).&#x20;In-vitro&#x20;measurement&#x20;was&#x20;conducted&#x20;via&#x20;air&#x20;pressurization&#x20;in&#x20;a&#x20;sealing&#x20;jig&#x20;(n&#x20;=&#x20;3).&#x20;Subsequently,&#x20;the&#x20;sensor&#x20;was&#x20;implanted&#x20;into&#x20;the&#x20;anterior&#x20;chamber&#x20;of&#x20;a&#x20;rabbit&#x20;eye.&#x20;In-vivo&#x20;measurement&#x20;was&#x20;performed&#x20;while&#x20;the&#x20;IOP&#x20;was&#x20;elevated&#x20;by&#x20;infusion&#x20;of&#x20;balanced&#x20;salt&#x20;solution&#x20;(BSS,&#x20;6&#x20;mu&#x20;L&#x2F;min).&#x20;Smaller-sized&#x20;sensors&#x20;later&#x20;were&#x20;implanted&#x20;into&#x20;two&#x20;rabbit&#x20;eyes,&#x20;which&#x20;were&#x20;microscopically&#x20;examined&#x20;at&#x20;2,&#x20;4&#x20;and&#x20;8&#x20;weeks&#x20;post-implantation.&#x20;The&#x20;eyes&#x20;were&#x20;then&#x20;immediately&#x20;enucleated&#x20;for&#x20;histological&#x20;examination.&#x20;Results:&#x20;The&#x20;in-vitro&#x20;measurement&#x20;showed&#x20;a&#x20;significant&#x20;RF&#x20;shift&#x20;as&#x20;pressure&#x20;in&#x20;the&#x20;jig&#x20;was&#x20;increased&#x20;from&#x20;0&#x20;mmHg&#x20;to&#x20;60&#x20;mmHg&#x20;(average&#x20;initial&#x20;frequency:&#x20;10.86&#x20;MHz,&#x20;average&#x20;shift:&#x20;403&#x20;kHz).&#x20;The&#x20;in-vivo&#x20;measurement&#x20;also&#x20;showed&#x20;an&#x20;RF&#x20;decrease,&#x20;from&#x20;12.80&#x20;MHz&#x20;to&#x20;12.67&#x20;MHz,&#x20;as&#x20;the&#x20;pressure&#x20;was&#x20;increased&#x20;from&#x20;10&#x20;mmHg&#x20;to&#x20;20&#x20;mmHg.&#x20;Microscopic&#x20;in-vivo&#x20;evaluations&#x20;and&#x20;histological&#x20;exams,&#x20;performed&#x20;at&#x20;intervals&#x20;up&#x20;to&#x20;8&#x20;weeks&#x20;post-implantation,&#x20;showed&#x20;no&#x20;evidence&#x20;of&#x20;significant&#x20;inflammation&#x20;or&#x20;deformity&#x20;of&#x20;the&#x20;ocular-tissue&#x20;structures.&#x20;Conclusions:&#x20;The&#x20;implantable&#x20;inductive-type&#x20;IOP&#x20;sensor&#x20;demonstrated&#x20;wireless&#x20;pressure-sensing&#x20;ability&#x20;and&#x20;favourable&#x20;biocompatibility&#x20;in&#x20;the&#x20;rabbit&#x20;eye.</dcvalue>
<dcvalue element="language" qualifier="none">English</dcvalue>
<dcvalue element="publisher" qualifier="none">WILEY</dcvalue>
<dcvalue element="subject" qualifier="none">VISUAL-FIELD&#x20;LOSS</dcvalue>
<dcvalue element="subject" qualifier="none">ADVANCED&#x20;GLAUCOMA&#x20;INTERVENTION</dcvalue>
<dcvalue element="subject" qualifier="none">OPEN-ANGLE&#x20;GLAUCOMA</dcvalue>
<dcvalue element="subject" qualifier="none">RISK-FACTOR</dcvalue>
<dcvalue element="subject" qualifier="none">TELEMETRY</dcvalue>
<dcvalue element="subject" qualifier="none">PATTERN</dcvalue>
<dcvalue element="subject" qualifier="none">PROGRESSION</dcvalue>
<dcvalue element="subject" qualifier="none">POSITION</dcvalue>
<dcvalue element="subject" qualifier="none">EYE</dcvalue>
<dcvalue element="title" qualifier="none">Preliminary&#x20;study&#x20;on&#x20;implantable&#x20;inductive-type&#x20;sensor&#x20;for&#x20;continuous&#x20;monitoring&#x20;of&#x20;intraocular&#x20;pressure</dcvalue>
<dcvalue element="type" qualifier="none">Article</dcvalue>
<dcvalue element="identifier" qualifier="doi">10.1111&#x2F;ceo.12573</dcvalue>
<dcvalue element="description" qualifier="journalClass">1</dcvalue>
<dcvalue element="identifier" qualifier="bibliographicCitation">CLINICAL&#x20;AND&#x20;EXPERIMENTAL&#x20;OPHTHALMOLOGY,&#x20;v.43,&#x20;no.9,&#x20;pp.830&#x20;-&#x20;837</dcvalue>
<dcvalue element="citation" qualifier="title">CLINICAL&#x20;AND&#x20;EXPERIMENTAL&#x20;OPHTHALMOLOGY</dcvalue>
<dcvalue element="citation" qualifier="volume">43</dcvalue>
<dcvalue element="citation" qualifier="number">9</dcvalue>
<dcvalue element="citation" qualifier="startPage">830</dcvalue>
<dcvalue element="citation" qualifier="endPage">837</dcvalue>
<dcvalue element="description" qualifier="journalRegisteredClass">scie</dcvalue>
<dcvalue element="description" qualifier="journalRegisteredClass">scopus</dcvalue>
<dcvalue element="identifier" qualifier="wosid">000368342700010</dcvalue>
<dcvalue element="identifier" qualifier="scopusid">2-s2.0-84949317010</dcvalue>
<dcvalue element="relation" qualifier="journalWebOfScienceCategory">Ophthalmology</dcvalue>
<dcvalue element="relation" qualifier="journalResearchArea">Ophthalmology</dcvalue>
<dcvalue element="type" qualifier="docType">Article</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">VISUAL-FIELD&#x20;LOSS</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">ADVANCED&#x20;GLAUCOMA&#x20;INTERVENTION</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">OPEN-ANGLE&#x20;GLAUCOMA</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">RISK-FACTOR</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">TELEMETRY</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">PATTERN</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">PROGRESSION</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">POSITION</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">EYE</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">continuous&#x20;monitoring</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">glaucoma</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">intraocular&#x20;pressure</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">implantable&#x20;sensor</dcvalue>
</dublin_core>
