<?xml version="1.0" encoding="utf-8" standalone="no"?>
<dublin_core schema="dc">
<dcvalue element="contributor" qualifier="author">Ko,&#x20;Young&#x20;Gun</dcvalue>
<dcvalue element="contributor" qualifier="author">Karng,&#x20;Sarng&#x20;Woo</dcvalue>
<dcvalue element="contributor" qualifier="author">Lee,&#x20;Gil&#x20;Sun</dcvalue>
<dcvalue element="contributor" qualifier="author">Choi,&#x20;Ung&#x20;Su</dcvalue>
<dcvalue element="date" qualifier="accessioned">2024-01-20T13:03:00Z</dcvalue>
<dcvalue element="date" qualifier="available">2024-01-20T13:03:00Z</dcvalue>
<dcvalue element="date" qualifier="created">2021-09-01</dcvalue>
<dcvalue element="date" qualifier="issued">2013-02</dcvalue>
<dcvalue element="identifier" qualifier="issn">0925-4005</dcvalue>
<dcvalue element="identifier" qualifier="uri">https:&#x2F;&#x2F;pubs.kist.re.kr&#x2F;handle&#x2F;201004&#x2F;128421</dcvalue>
<dcvalue element="description" qualifier="abstract">This&#x20;paper&#x20;reports&#x20;the&#x20;fabrication&#x20;of&#x20;new&#x20;chemosensor&#x20;based&#x20;on&#x20;the&#x20;aminoacridine&#x20;immobilized&#x20;glass&#x20;substrate.&#x20;The&#x20;fabricated&#x20;chemosensor&#x20;was&#x20;highly&#x20;selective&#x20;and&#x20;sensitive&#x20;for&#x20;the&#x20;detection&#x20;of&#x20;Ag+.&#x20;Although&#x20;each&#x20;of&#x20;the&#x20;chemosensing&#x20;molecules&#x20;on&#x20;the&#x20;glass&#x20;substrate&#x20;does&#x20;not&#x20;have&#x20;the&#x20;specific&#x20;ligand,&#x20;the&#x20;molecules&#x20;got&#x20;specific&#x20;selectivity&#x20;for&#x20;Ag+&#x20;owing&#x20;to&#x20;the&#x20;suitable&#x20;distance&#x20;between&#x20;them.&#x20;Ag+&#x20;formed&#x20;the&#x20;chelating&#x20;complex&#x20;with&#x20;the&#x20;chemosensing&#x20;molecules&#x20;as&#x20;not&#x20;intra-&#x20;but&#x20;inter-molecular&#x20;structure.&#x20;After&#x20;the&#x20;formation&#x20;of&#x20;the&#x20;chelating&#x20;complex,&#x20;surface&#x20;properties,&#x20;such&#x20;as&#x20;the&#x20;morphology&#x20;and&#x20;the&#x20;wettability,&#x20;were&#x20;changed&#x20;owing&#x20;to&#x20;the&#x20;bent&#x20;amidine&#x20;groups&#x20;of&#x20;the&#x20;chemosensing&#x20;molecules&#x20;on&#x20;the&#x20;glass&#x20;substrate.&#x20;The&#x20;chemical&#x20;structure&#x20;and&#x20;the&#x20;surface&#x20;properties&#x20;of&#x20;the&#x20;chemosensor-Ag+&#x20;were&#x20;analyzed&#x20;using&#x20;X-ray&#x20;photoelectron&#x20;spectroscopy&#x20;(XPS),&#x20;atomic&#x20;force&#x20;microscopy&#x20;(AFM),&#x20;and&#x20;contact&#x20;angle&#x20;goniometer.&#x20;Combining&#x20;these&#x20;techniques&#x20;enables&#x20;discussion&#x20;of&#x20;mechanism&#x20;of&#x20;the&#x20;chemosensor-Ag+&#x20;complex.&#x20;In&#x20;addition,&#x20;the&#x20;prepared&#x20;chemosensor&#x20;showed&#x20;a&#x20;selective&#x20;absorbance&#x20;change&#x20;only&#x20;with&#x20;Ag+,&#x20;indicating&#x20;that&#x20;the&#x20;sensing&#x20;system&#x20;described&#x20;herein&#x20;exhibits&#x20;high&#x20;selectivity&#x20;for&#x20;Ag+&#x20;detection&#x20;against&#x20;other&#x20;metal&#x20;ions.&#x20;(c)&#x20;2012&#x20;Elsevier&#x20;B.V.&#x20;All&#x20;rights&#x20;reserved.</dcvalue>
<dcvalue element="language" qualifier="none">English</dcvalue>
<dcvalue element="publisher" qualifier="none">ELSEVIER&#x20;SCIENCE&#x20;SA</dcvalue>
<dcvalue element="title" qualifier="none">Smart&#x20;glass&#x20;substrate&#x20;as&#x20;colorimetric&#x20;chemosensor&#x20;for&#x20;highly&#x20;selective&#x20;detection&#x20;of&#x20;silver&#x20;ion</dcvalue>
<dcvalue element="type" qualifier="none">Article</dcvalue>
<dcvalue element="identifier" qualifier="doi">10.1016&#x2F;j.snb.2012.12.032</dcvalue>
<dcvalue element="description" qualifier="journalClass">1</dcvalue>
<dcvalue element="identifier" qualifier="bibliographicCitation">SENSORS&#x20;AND&#x20;ACTUATORS&#x20;B-CHEMICAL,&#x20;v.177,&#x20;pp.1107&#x20;-&#x20;1114</dcvalue>
<dcvalue element="citation" qualifier="title">SENSORS&#x20;AND&#x20;ACTUATORS&#x20;B-CHEMICAL</dcvalue>
<dcvalue element="citation" qualifier="volume">177</dcvalue>
<dcvalue element="citation" qualifier="startPage">1107</dcvalue>
<dcvalue element="citation" qualifier="endPage">1114</dcvalue>
<dcvalue element="description" qualifier="isOpenAccess">N</dcvalue>
<dcvalue element="description" qualifier="journalRegisteredClass">scie</dcvalue>
<dcvalue element="description" qualifier="journalRegisteredClass">scopus</dcvalue>
<dcvalue element="identifier" qualifier="wosid">000315751000146</dcvalue>
<dcvalue element="identifier" qualifier="scopusid">2-s2.0-84872161406</dcvalue>
<dcvalue element="relation" qualifier="journalWebOfScienceCategory">Chemistry,&#x20;Analytical</dcvalue>
<dcvalue element="relation" qualifier="journalWebOfScienceCategory">Electrochemistry</dcvalue>
<dcvalue element="relation" qualifier="journalWebOfScienceCategory">Instruments&#x20;&amp;&#x20;Instrumentation</dcvalue>
<dcvalue element="relation" qualifier="journalResearchArea">Chemistry</dcvalue>
<dcvalue element="relation" qualifier="journalResearchArea">Electrochemistry</dcvalue>
<dcvalue element="relation" qualifier="journalResearchArea">Instruments&#x20;&amp;&#x20;Instrumentation</dcvalue>
<dcvalue element="type" qualifier="docType">Article</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">GOLD</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">ABSORPTION</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">SENSOR</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">ALKYL</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Chemosensor</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Ag+</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Chemosensing&#x20;glass&#x20;substrate</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">XPS</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Aminoacridine</dcvalue>
</dublin_core>