<?xml version="1.0" encoding="utf-8" standalone="no"?>
<dublin_core schema="dc">
<dcvalue element="contributor" qualifier="author">Kim,&#x20;Youngjun</dcvalue>
<dcvalue element="contributor" qualifier="author">Kim,&#x20;Kang-Il</dcvalue>
<dcvalue element="contributor" qualifier="author">Choi,&#x20;Jin&#x20;Hyeok</dcvalue>
<dcvalue element="contributor" qualifier="author">Lee,&#x20;Kunwoo</dcvalue>
<dcvalue element="date" qualifier="accessioned">2024-01-20T17:04:11Z</dcvalue>
<dcvalue element="date" qualifier="available">2024-01-20T17:04:11Z</dcvalue>
<dcvalue element="date" qualifier="created">2021-09-02</dcvalue>
<dcvalue element="date" qualifier="issued">2011-05</dcvalue>
<dcvalue element="identifier" qualifier="issn">0268-0033</dcvalue>
<dcvalue element="identifier" qualifier="uri">https:&#x2F;&#x2F;pubs.kist.re.kr&#x2F;handle&#x2F;201004&#x2F;130429</dcvalue>
<dcvalue element="description" qualifier="abstract">Background:&#x20;Radiographic&#x20;evaluation&#x20;of&#x20;patients&#x20;after&#x20;total&#x20;knee&#x20;arthroplasty&#x20;is&#x20;an&#x20;important&#x20;tool&#x20;for&#x20;assessing&#x20;the&#x20;correct&#x20;position&#x20;of&#x20;the&#x20;implants&#x20;and&#x20;the&#x20;axis&#x20;of&#x20;limb&#x20;alignment&#x20;because&#x20;this&#x20;will&#x20;determine&#x20;long-term&#x20;durability&#x20;of&#x20;the&#x20;implants.&#x20;Recently,&#x20;2D-3D&#x20;medical&#x20;image&#x20;registration&#x20;methods&#x20;are&#x20;developed&#x20;for&#x20;3D&#x20;postoperative&#x20;analysis&#x20;of&#x20;total&#x20;knee&#x20;arthroplasty.&#x20;However,&#x20;most&#x20;of&#x20;these&#x20;techniques&#x20;have&#x20;focused&#x20;only&#x20;on&#x20;knee&#x20;implants.&#x20;Methods:&#x20;A&#x20;2D-3D&#x20;medical&#x20;image&#x20;registration&#x20;is&#x20;implemented&#x20;to&#x20;compute&#x20;the&#x20;3D&#x20;positions&#x20;of&#x20;not&#x20;only&#x20;implants&#x20;but&#x20;also&#x20;lower&#x20;limb&#x20;bones.&#x20;The&#x20;following&#x20;3D&#x20;postoperative&#x20;analysis&#x20;methods&#x20;for&#x20;total&#x20;knee&#x20;arthroplasty&#x20;are&#x20;presented&#x20;in&#x20;this&#x20;paper:&#x20;(1)&#x20;automatic&#x20;calculation&#x20;of&#x20;relative&#x20;angles&#x20;of&#x20;implants&#x20;and&#x20;bones,&#x20;(2)&#x20;assessment&#x20;of&#x20;external&#x20;rotation&#x20;angles&#x20;of&#x20;inserted&#x20;implants,&#x20;and&#x20;(3)&#x20;measurement&#x20;and&#x20;comparison&#x20;of&#x20;both&#x20;flexion-extension&#x20;gap&#x20;balances.&#x20;Finally&#x20;these&#x20;methods&#x20;have&#x20;been&#x20;applied&#x20;in&#x20;five&#x20;patients&#x20;who&#x20;underwent&#x20;total&#x20;knee&#x20;replacements.&#x20;Findings:&#x20;A&#x20;practical&#x20;method&#x20;that&#x20;can&#x20;evaluate&#x20;the&#x20;patient&amp;apos;s&#x20;knee&#x20;conditions&#x20;has&#x20;been&#x20;successfully&#x20;developed.&#x20;The&#x20;repeatability&#x20;and&#x20;accuracy&#x20;of&#x20;2D-3D&#x20;registration&#x20;were&#x20;around&#x20;0.2&#x20;mm&#x20;as&#x20;obtained&#x20;from&#x20;the&#x20;tests&#x20;using&#x20;model&#x20;bones.&#x20;Based&#x20;on&#x20;the&#x20;3D&#x20;information,&#x20;the&#x20;novel&#x20;methods&#x20;of&#x20;postoperative&#x20;analysis&#x20;were&#x20;proposed&#x20;and&#x20;successfully&#x20;applied&#x20;to&#x20;the&#x20;patients.&#x20;Interpretation:&#x20;The&#x20;3D&#x20;positions&#x20;for&#x20;both&#x20;knee&#x20;implants&#x20;and&#x20;lower&#x20;limb&#x20;bones&#x20;can&#x20;be&#x20;calculated&#x20;in&#x20;order&#x20;to&#x20;perform&#x20;comprehensive&#x20;postoperative&#x20;analyses&#x20;of&#x20;total&#x20;knee&#x20;arthroplasty.&#x20;The&#x20;proposed&#x20;analyses&#x20;of&#x20;the&#x20;postoperative&#x20;evaluations&#x20;facilitated&#x20;various&#x20;3D&#x20;evaluations&#x20;of&#x20;the&#x20;status&#x20;of&#x20;implants,&#x20;alignment&#x20;of&#x20;lower&#x20;limb&#x20;and&#x20;gap&#x20;balances&#x20;which&#x20;were&#x20;not&#x20;previously&#x20;feasible.&#x20;(C)&#x20;2010&#x20;Elsevier&#x20;Ltd.&#x20;All&#x20;rights&#x20;reserved.</dcvalue>
<dcvalue element="language" qualifier="none">English</dcvalue>
<dcvalue element="publisher" qualifier="none">ELSEVIER&#x20;SCI&#x20;LTD</dcvalue>
<dcvalue element="subject" qualifier="none">FEMORAL&#x20;COMPONENT</dcvalue>
<dcvalue element="subject" qualifier="none">ROTATIONAL&#x20;ALIGNMENT</dcvalue>
<dcvalue element="subject" qualifier="none">PATELLAR&#x20;TRACKING</dcvalue>
<dcvalue element="subject" qualifier="none">X-RAY</dcvalue>
<dcvalue element="subject" qualifier="none">FLUOROSCOPY</dcvalue>
<dcvalue element="subject" qualifier="none">KINEMATICS</dcvalue>
<dcvalue element="subject" qualifier="none">SYSTEM</dcvalue>
<dcvalue element="subject" qualifier="none">AXIS</dcvalue>
<dcvalue element="subject" qualifier="none">CT</dcvalue>
<dcvalue element="title" qualifier="none">Novel&#x20;methods&#x20;for&#x20;3D&#x20;postoperative&#x20;analysis&#x20;of&#x20;total&#x20;knee&#x20;arthroplasty&#x20;using&#x20;2D-3D&#x20;image&#x20;registration</dcvalue>
<dcvalue element="type" qualifier="none">Article</dcvalue>
<dcvalue element="identifier" qualifier="doi">10.1016&#x2F;j.clinbiomech.2010.11.013</dcvalue>
<dcvalue element="description" qualifier="journalClass">1</dcvalue>
<dcvalue element="identifier" qualifier="bibliographicCitation">CLINICAL&#x20;BIOMECHANICS,&#x20;v.26,&#x20;no.4,&#x20;pp.384&#x20;-&#x20;391</dcvalue>
<dcvalue element="citation" qualifier="title">CLINICAL&#x20;BIOMECHANICS</dcvalue>
<dcvalue element="citation" qualifier="volume">26</dcvalue>
<dcvalue element="citation" qualifier="number">4</dcvalue>
<dcvalue element="citation" qualifier="startPage">384</dcvalue>
<dcvalue element="citation" qualifier="endPage">391</dcvalue>
<dcvalue element="description" qualifier="journalRegisteredClass">scie</dcvalue>
<dcvalue element="description" qualifier="journalRegisteredClass">scopus</dcvalue>
<dcvalue element="identifier" qualifier="wosid">000289917300010</dcvalue>
<dcvalue element="identifier" qualifier="scopusid">2-s2.0-79953283728</dcvalue>
<dcvalue element="relation" qualifier="journalWebOfScienceCategory">Engineering,&#x20;Biomedical</dcvalue>
<dcvalue element="relation" qualifier="journalWebOfScienceCategory">Orthopedics</dcvalue>
<dcvalue element="relation" qualifier="journalWebOfScienceCategory">Sport&#x20;Sciences</dcvalue>
<dcvalue element="relation" qualifier="journalResearchArea">Engineering</dcvalue>
<dcvalue element="relation" qualifier="journalResearchArea">Orthopedics</dcvalue>
<dcvalue element="relation" qualifier="journalResearchArea">Sport&#x20;Sciences</dcvalue>
<dcvalue element="type" qualifier="docType">Article</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">FEMORAL&#x20;COMPONENT</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">ROTATIONAL&#x20;ALIGNMENT</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">PATELLAR&#x20;TRACKING</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">X-RAY</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">FLUOROSCOPY</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">KINEMATICS</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">SYSTEM</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">AXIS</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">CT</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Three&#x20;dimensional</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Postoperative&#x20;analysis</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Total&#x20;knee&#x20;arthroplasty</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Registration</dcvalue>
</dublin_core>
