<?xml version="1.0" encoding="utf-8" standalone="no"?>
<dublin_core schema="dc">
<dcvalue element="contributor" qualifier="author">Kim,&#x20;Guk&#x20;Bae</dcvalue>
<dcvalue element="contributor" qualifier="author">Lee,&#x20;Sang&#x20;Joon</dcvalue>
<dcvalue element="date" qualifier="accessioned">2024-01-20T21:35:39Z</dcvalue>
<dcvalue element="date" qualifier="available">2024-01-20T21:35:39Z</dcvalue>
<dcvalue element="date" qualifier="created">2022-01-25</dcvalue>
<dcvalue element="date" qualifier="issued">2009-03</dcvalue>
<dcvalue element="identifier" qualifier="issn">0021-9290</dcvalue>
<dcvalue element="identifier" qualifier="uri">https:&#x2F;&#x2F;pubs.kist.re.kr&#x2F;handle&#x2F;201004&#x2F;132663</dcvalue>
<dcvalue element="description" qualifier="abstract">Hemodynamics&#x20;has&#x20;been&#x20;a&#x20;very&#x20;important&#x20;factor&#x20;in&#x20;understanding&#x20;and&#x20;diagnosing&#x20;various&#x20;vascular&#x20;diseases.&#x20;Recently,&#x20;the&#x20;X-ray&#x20;particle&#x20;image&#x20;velocimetry&#x20;(X-ray&#x20;PIV)&#x20;method&#x20;using&#x20;speckle&#x20;patterns&#x20;of&#x20;blood&#x20;has&#x20;been&#x20;introduced&#x20;as&#x20;a&#x20;new&#x20;quantitative&#x20;visualization&#x20;method&#x20;for&#x20;blood&#x20;flows&#x20;without&#x20;any&#x20;seeding&#x20;tracer&#x20;or&#x20;contrast&#x20;agents.&#x20;In&#x20;this&#x20;study,&#x20;the&#x20;peculiar&#x20;optical&#x20;characteristics&#x20;of&#x20;blood&#x20;on&#x20;the&#x20;synchrotron&#x20;X-ray&#x20;imaging&#x20;method,&#x20;which&#x20;were&#x20;not&#x20;presented&#x20;in&#x20;previous&#x20;studies,&#x20;were&#x20;investigated&#x20;in&#x20;depth&#x20;and&#x20;systematically.&#x20;The&#x20;experimental&#x20;conditions&#x20;required&#x20;for&#x20;X-ray&#x20;PIV&#x20;application&#x20;were&#x20;found&#x20;to&#x20;be&#x20;the&#x20;distance&#x20;between&#x20;the&#x20;sample&#x20;and&#x20;the&#x20;scintillator&#x20;(similar&#x20;to&#x20;40cm),&#x20;the&#x20;thickening&#x20;of&#x20;the&#x20;blood&#x20;sample&#x20;(&gt;&#x20;0.3&#x20;min),&#x20;and&#x20;hematocrit&#x20;(20.0-80.0%).&#x20;In&#x20;addition,&#x20;we&#x20;verified&#x20;that&#x20;the&#x20;X-ray&#x20;PIV&#x20;method&#x20;is&#x20;reliable&#x20;as&#x20;an&#x20;advanced&#x20;flow&#x20;velocimetry&#x20;by&#x20;comparing&#x20;the&#x20;flow&#x20;rate&#x20;evaluated&#x20;from&#x20;the&#x20;X-ray&#x20;PIV&#x20;result&#x20;and&#x20;the&#x20;input&#x20;flow&#x20;rate&#x20;supplied&#x20;from&#x20;a&#x20;syringe&#x20;pump&#x20;with&#x20;an&#x20;error&#x20;of&#x20;less&#x20;than&#x20;1%.&#x20;Through&#x20;this&#x20;study,&#x20;based&#x20;on&#x20;the&#x20;understanding&#x20;of&#x20;contrast&#x20;enhancement&#x20;mechanisms&#x20;of&#x20;speckle&#x20;patterns&#x20;from&#x20;blood,&#x20;we&#x20;Could&#x20;establish&#x20;a&#x20;trustworthy&#x20;flow&#x20;visualization&#x20;method&#x20;that&#x20;can&#x20;be&#x20;used&#x20;effectively&#x20;in&#x20;hemodynamic&#x20;studies.&#x20;(c)&#x20;2008&#x20;Elsevier&#x20;Ltd.&#x20;All&#x20;rights&#x20;reserved.</dcvalue>
<dcvalue element="language" qualifier="none">English</dcvalue>
<dcvalue element="publisher" qualifier="none">ELSEVIER&#x20;SCI&#x20;LTD</dcvalue>
<dcvalue element="title" qualifier="none">Contrast&#x20;enhancement&#x20;of&#x20;speckle&#x20;patterns&#x20;from&#x20;blood&#x20;in&#x20;synchrotron&#x20;X-ray&#x20;imaging</dcvalue>
<dcvalue element="type" qualifier="none">Article</dcvalue>
<dcvalue element="identifier" qualifier="doi">10.1016&#x2F;j.jbiomech.2008.11.037</dcvalue>
<dcvalue element="description" qualifier="journalClass">1</dcvalue>
<dcvalue element="identifier" qualifier="bibliographicCitation">JOURNAL&#x20;OF&#x20;BIOMECHANICS,&#x20;v.42,&#x20;no.4,&#x20;pp.449&#x20;-&#x20;454</dcvalue>
<dcvalue element="citation" qualifier="title">JOURNAL&#x20;OF&#x20;BIOMECHANICS</dcvalue>
<dcvalue element="citation" qualifier="volume">42</dcvalue>
<dcvalue element="citation" qualifier="number">4</dcvalue>
<dcvalue element="citation" qualifier="startPage">449</dcvalue>
<dcvalue element="citation" qualifier="endPage">454</dcvalue>
<dcvalue element="description" qualifier="isOpenAccess">N</dcvalue>
<dcvalue element="description" qualifier="journalRegisteredClass">scie</dcvalue>
<dcvalue element="description" qualifier="journalRegisteredClass">scopus</dcvalue>
<dcvalue element="identifier" qualifier="wosid">000264507300007</dcvalue>
<dcvalue element="identifier" qualifier="scopusid">2-s2.0-60549100292</dcvalue>
<dcvalue element="relation" qualifier="journalWebOfScienceCategory">Biophysics</dcvalue>
<dcvalue element="relation" qualifier="journalWebOfScienceCategory">Engineering,&#x20;Biomedical</dcvalue>
<dcvalue element="relation" qualifier="journalResearchArea">Biophysics</dcvalue>
<dcvalue element="relation" qualifier="journalResearchArea">Engineering</dcvalue>
<dcvalue element="type" qualifier="docType">Article</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">SHEAR-STRESS</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">WALL&#x20;SHEAR</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">FLOW</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">ARTERY</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">VELOCIMETRY</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">MICROSCOPY</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">RESPONSES</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">DIAMETER</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Synchrotron&#x20;X-ray&#x20;imaging&#x20;method</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">X-ray&#x20;PIV</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Contrast&#x20;enhancement</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Speckle&#x20;patterns&#x20;of&#x20;blood</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Flow&#x20;velocimetry</dcvalue>
</dublin_core>
