<?xml version="1.0" encoding="utf-8" standalone="no"?>
<dublin_core schema="dc">
<dcvalue element="contributor" qualifier="author">Chin,&#x20;Sungmin</dcvalue>
<dcvalue element="contributor" qualifier="author">Jurng,&#x20;Jongsoo</dcvalue>
<dcvalue element="contributor" qualifier="author">Lee,&#x20;Jae-Heon</dcvalue>
<dcvalue element="contributor" qualifier="author">Hur,&#x20;Jin-Huek</dcvalue>
<dcvalue element="date" qualifier="accessioned">2024-01-20T22:06:23Z</dcvalue>
<dcvalue element="date" qualifier="available">2024-01-20T22:06:23Z</dcvalue>
<dcvalue element="date" qualifier="created">2021-09-03</dcvalue>
<dcvalue element="date" qualifier="issued">2008-12</dcvalue>
<dcvalue element="identifier" qualifier="issn">0956-053X</dcvalue>
<dcvalue element="identifier" qualifier="uri">https:&#x2F;&#x2F;pubs.kist.re.kr&#x2F;handle&#x2F;201004&#x2F;132940</dcvalue>
<dcvalue element="description" qualifier="abstract">Pilot-plant&#x20;experiments&#x20;were&#x20;performed&#x20;to&#x20;evaluate&#x20;the&#x20;effect&#x20;of&#x20;oxygen&#x20;enrichment&#x20;oil&#x20;the&#x20;co-incineration&#x20;of&#x20;MSW&#x20;and&#x20;organic&#x20;sludge&#x20;from&#x20;a&#x20;wastewater&#x20;treatment&#x20;facility.&#x20;Combustion&#x20;chamber&#x20;temperatures,&#x20;stack&#x20;gas&#x20;concentrations,&#x20;i.e.,&#x20;CO2&#x20;and&#x20;CO,&#x20;and&#x20;the&#x20;residual&#x20;oxygen&#x20;were&#x20;measured.&#x20;The&#x20;maximum&#x20;ratio&#x20;of&#x20;organic&#x20;sludge&#x20;waste&#x20;to&#x20;total&#x20;waste&#x20;input&#x20;was&#x20;30&#x20;wt.%.&#x20;Oxygen-enriched&#x20;air,&#x20;22&#x20;vol.%&#x20;(dry&#x20;basis)&#x20;oxygen,&#x20;was&#x20;used&#x20;for&#x20;stable&#x20;combustion.&#x20;As&#x20;the&#x20;co-incineration&#x20;ratio&#x20;of&#x20;the&#x20;sludge&#x20;increased,&#x20;the&#x20;primary&#x20;and&#x20;secondary&#x20;combustion&#x20;chamber&#x20;temperatures&#x20;were&#x20;decreased&#x20;to&#x20;900&#x20;and&#x20;750&#x20;degrees&#x20;C,&#x20;respectively,&#x20;approximately&#x20;100&#x20;degrees&#x20;C&#x20;below&#x20;the&#x20;proper&#x20;incineration.&#x20;However,&#x20;if&#x20;the&#x20;supplied&#x20;air&#x20;was&#x20;enriched&#x20;with&#x20;22&#x20;vol.%&#x20;(dry&#x20;basis)&#x20;oxygen&#x20;content,&#x20;the&#x20;incinerator&#x20;temperature&#x20;was&#x20;high&#x20;enough&#x20;to&#x20;burn&#x20;the&#x20;waste&#x20;mixture&#x20;containing&#x20;30&#x20;wt.%&#x20;moisture&#x20;sludge,&#x20;with&#x20;an&#x20;estimated&#x20;heating&#x20;value&#x20;of&#x20;6.72&#x20;MJ&#x2F;kg.&#x20;There&#x20;are&#x20;two&#x20;main&#x20;benefits&#x20;of&#x20;using&#x20;oxygen&#x20;enrichment&#x20;in&#x20;the&#x20;co-incineration.&#x20;First,&#x20;the&#x20;sensible&#x20;heat&#x20;can&#x20;be&#x20;reduced&#x20;as&#x20;the&#x20;quantity&#x20;of&#x20;nitrogen&#x20;in&#x20;the&#x20;flue&#x20;gas&#x20;will&#x20;be&#x20;decreased.&#x20;Second,&#x20;the&#x20;unburned&#x20;carbon&#x20;formation&#x20;is&#x20;reduced&#x20;due&#x20;to&#x20;the&#x20;oxygen-enriched&#x20;burning&#x20;of&#x20;the&#x20;waste,&#x20;despite&#x20;an&#x20;increase&#x20;in&#x20;the&#x20;sludge&#x20;co-incineration&#x20;ratio.&#x20;(C)&#x20;2008&#x20;Elsevier&#x20;Ltd.&#x20;All&#x20;rights&#x20;reserved.</dcvalue>
<dcvalue element="language" qualifier="none">English</dcvalue>
<dcvalue element="publisher" qualifier="none">PERGAMON-ELSEVIER&#x20;SCIENCE&#x20;LTD</dcvalue>
<dcvalue element="subject" qualifier="none">FLUIDIZED-BED</dcvalue>
<dcvalue element="title" qualifier="none">Oxygen-enriched&#x20;air&#x20;for&#x20;co-incineration&#x20;of&#x20;organic&#x20;sludges&#x20;with&#x20;municipal&#x20;solid&#x20;waste:&#x20;A&#x20;pilot&#x20;plant&#x20;experiment</dcvalue>
<dcvalue element="type" qualifier="none">Article</dcvalue>
<dcvalue element="identifier" qualifier="doi">10.1016&#x2F;j.wasman.2008.01.004</dcvalue>
<dcvalue element="description" qualifier="journalClass">1</dcvalue>
<dcvalue element="identifier" qualifier="bibliographicCitation">WASTE&#x20;MANAGEMENT,&#x20;v.28,&#x20;no.12,&#x20;pp.2684&#x20;-&#x20;2689</dcvalue>
<dcvalue element="citation" qualifier="title">WASTE&#x20;MANAGEMENT</dcvalue>
<dcvalue element="citation" qualifier="volume">28</dcvalue>
<dcvalue element="citation" qualifier="number">12</dcvalue>
<dcvalue element="citation" qualifier="startPage">2684</dcvalue>
<dcvalue element="citation" qualifier="endPage">2689</dcvalue>
<dcvalue element="description" qualifier="journalRegisteredClass">scie</dcvalue>
<dcvalue element="description" qualifier="journalRegisteredClass">scopus</dcvalue>
<dcvalue element="identifier" qualifier="wosid">000261283600027</dcvalue>
<dcvalue element="identifier" qualifier="scopusid">2-s2.0-54349104979</dcvalue>
<dcvalue element="relation" qualifier="journalWebOfScienceCategory">Engineering,&#x20;Environmental</dcvalue>
<dcvalue element="relation" qualifier="journalWebOfScienceCategory">Environmental&#x20;Sciences</dcvalue>
<dcvalue element="relation" qualifier="journalResearchArea">Engineering</dcvalue>
<dcvalue element="relation" qualifier="journalResearchArea">Environmental&#x20;Sciences&#x20;&amp;&#x20;Ecology</dcvalue>
<dcvalue element="type" qualifier="docType">Article</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">FLUIDIZED-BED</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">waste</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">oxygen-enriched</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">sludge</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">co-incineration</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">pilot&#x20;plant</dcvalue>
</dublin_core>
