<dcvalue element="description" qualifier="abstract">This&#x20;paper&#x20;describes&#x20;the&#x20;conceptual&#x20;development&#x20;and&#x20;idea&#x20;verification&#x20;of&#x20;a&#x20;subminiature&#x20;portable&#x20;cooler&#x20;that&#x20;does&#x20;not&#x20;necessitate&#x20;any&#x20;precooling&#x20;nor&#x20;any&#x20;external&#x20;energy&#x20;supply&#x20;during&#x20;the&#x20;process&#x20;of&#x20;cooling.&#x20;The&#x20;basic&#x20;principle&#x20;of&#x20;the&#x20;cooling&#x20;mechanism&#x20;is&#x20;the&#x20;vaporization&#x20;of&#x20;water&#x20;and&#x20;subsequent&#x20;cooling&#x20;due&#x20;to&#x20;the&#x20;evaporative&#x20;latent&#x20;heat&#x20;loss.&#x20;In&#x20;this&#x20;work,,&#x20;the&#x20;vaporization&#x20;of&#x20;the&#x20;water&#x20;was&#x20;stimulated&#x20;by&#x20;a&#x20;desiccant&#x20;material&#x20;to&#x20;improve&#x20;the&#x20;cooling&#x20;effect.&#x20;By&#x20;using&#x20;a&#x20;pre-activated&#x20;desiccant,&#x20;considerable&#x20;cooling&#x20;effect&#x20;can&#x20;be&#x20;obtained&#x20;until&#x20;the&#x20;desiccant&#x20;becomes&#x20;saturated&#x20;with&#x20;the&#x20;absorbed&#x20;moisture.&#x20;The&#x20;evaporative&#x20;cooling&#x20;caused&#x20;by&#x20;the&#x20;desiccant&#x20;was&#x20;modeled&#x20;and&#x20;analyzed&#x20;with&#x20;consideration&#x20;given&#x20;to&#x20;the&#x20;sorption&#x20;characteristics&#x20;of&#x20;the&#x20;desiccant.&#x20;In&#x20;addition,&#x20;the&#x20;portable&#x20;cooler&#x20;was&#x20;fabricated&#x20;in&#x20;a&#x20;shape&#x20;of&#x20;a&#x20;thin&#x20;pad,&#x20;and&#x20;its&#x20;cooling&#x20;characteristics&#x20;were&#x20;tested&#x20;and&#x20;compared&#x20;with&#x20;the&#x20;analytic&#x20;results.&#x20;The&#x20;results&#x20;show&#x20;that&#x20;the&#x20;cool&#x20;pad&#x20;can&#x20;reduce&#x20;its&#x20;temperature&#x20;at&#x20;the&#x20;cold&#x20;side&#x20;from&#x20;its&#x20;initial&#x20;temperature,&#x20;30&#x20;degrees&#x20;C(86&#x20;degrees&#x20;F)&#x20;down&#x20;to&#x20;17&#x20;degrees&#x20;C(62.6&#x20;degrees&#x20;F)&#x20;within&#x20;ten&#x20;minutes&#x20;without&#x20;any&#x20;energy&#x20;supply&#x20;and&#x20;keep&#x20;the&#x20;low&#x20;temperature&#x20;for&#x20;about&#x20;an&#x20;hour.</dcvalue>
<dcvalue element="language" qualifier="none">English</dcvalue>
<dcvalue element="publisher" qualifier="none">AMER&#x20;SOC&#x20;HEATING&#x20;REFRIGERATING&#x20;AIR-CONDITIONING&#x20;ENG,&#x20;INC,</dcvalue>
<dcvalue element="title" qualifier="none">Subminiature&#x20;cool&#x20;pad&#x20;applying&#x20;sorption&#x20;cooling&#x20;effect</dcvalue>
<dcvalue element="type" qualifier="none">Article</dcvalue>
<dcvalue element="identifier" qualifier="doi">10.1080&#x2F;10789669.2006.10391208</dcvalue>
<dcvalue element="description" qualifier="journalClass">1</dcvalue>
<dcvalue element="identifier" qualifier="bibliographicCitation">HVAC&amp;R&#x20;RESEARCH,&#x20;v.12,&#x20;no.3B,&#x20;pp.797&#x20;-&#x20;806</dcvalue>
<dcvalue element="citation" qualifier="title">HVAC&amp;R&#x20;RESEARCH</dcvalue>
<dcvalue element="citation" qualifier="volume">12</dcvalue>
<dcvalue element="citation" qualifier="number">3B</dcvalue>
<dcvalue element="citation" qualifier="startPage">797</dcvalue>
<dcvalue element="citation" qualifier="endPage">806</dcvalue>
<dcvalue element="description" qualifier="journalRegisteredClass">scie</dcvalue>
<dcvalue element="description" qualifier="journalRegisteredClass">scopus</dcvalue>
<dcvalue element="identifier" qualifier="wosid">000240027500007</dcvalue>
<dcvalue element="identifier" qualifier="scopusid">2-s2.0-33748796085</dcvalue>
<dcvalue element="relation" qualifier="journalWebOfScienceCategory">Thermodynamics</dcvalue>
<dcvalue element="relation" qualifier="journalWebOfScienceCategory">Construction&#x20;&amp;&#x20;Building&#x20;Technology</dcvalue>
<dcvalue element="relation" qualifier="journalWebOfScienceCategory">Engineering,&#x20;Mechanical</dcvalue>
<dcvalue element="relation" qualifier="journalResearchArea">Thermodynamics</dcvalue>
<dcvalue element="relation" qualifier="journalResearchArea">Construction&#x20;&amp;&#x20;Building&#x20;Technology</dcvalue>
<dcvalue element="relation" qualifier="journalResearchArea">Engineering</dcvalue>
<dcvalue element="type" qualifier="docType">Article;&#x20;Proceedings&#x20;Paper</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Cool&#x20;Pad</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Sorption&#x20;Cooling</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Desiccant</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Evaporative&#x20;Cooling</dcvalue>