<?xml version="1.0" encoding="utf-8" standalone="no"?>
<dublin_core schema="dc">
<dcvalue element="contributor" qualifier="author">강병하</dcvalue>
<dcvalue element="contributor" qualifier="author">이정훈</dcvalue>
<dcvalue element="contributor" qualifier="author">김호영</dcvalue>
<dcvalue element="date" qualifier="accessioned">2024-01-21T06:12:41Z</dcvalue>
<dcvalue element="date" qualifier="available">2024-01-21T06:12:41Z</dcvalue>
<dcvalue element="date" qualifier="created">2021-09-06</dcvalue>
<dcvalue element="date" qualifier="issued">2004-10</dcvalue>
<dcvalue element="identifier" qualifier="issn">1229-6422</dcvalue>
<dcvalue element="identifier" qualifier="uri">https:&#x2F;&#x2F;pubs.kist.re.kr&#x2F;handle&#x2F;201004&#x2F;137174</dcvalue>
<dcvalue element="description" qualifier="abstract">Infrared&#x20;(IR)&#x20;detectors&#x20;are&#x20;widely&#x20;used&#x20;for&#x20;many&#x20;applications,&#x20;such&#x20;as&#x20;temperature&#x20;measurement,&#x20;intruder&#x20;and&#x20;fire&#x20;detection,&#x20;robotics&#x20;and&#x20;industrial&#x20;equipment,&#x20;thermoelstic&#x20;stress&#x20;analysis,&#x20;medical&#x20;diagnostics,&#x20;and&#x20;chemical&#x20;analysis.&#x20;Quantum&#x20;detectors&#x20;commonly&#x20;need&#x20;to&#x20;be&#x20;refrigerated&#x20;below&#x20;80&#x20;K,&#x20;and&#x20;thus&#x20;a&#x20;cooling&#x20;system&#x20;should&#x20;be&#x20;equipped&#x20;together&#x20;with&#x20;the&#x20;detector&#x20;system.&#x20;The&#x20;cooling&#x20;load,&#x20;which&#x20;should&#x20;be&#x20;removed&#x20;by&#x20;the&#x20;cooling&#x20;system&#x20;to&#x20;maintain&#x20;the&#x20;nominal&#x20;operating&#x20;temperature&#x20;of&#x20;the&#x20;detector,&#x20;critically&#x20;depends&#x20;on&#x20;the&#x20;insulation&#x20;efficiency&#x20;of&#x20;the&#x20;cryochamber&#x20;housing&#x20;the&#x20;detector.&#x20;Thermal&#x20;analysis&#x20;of&#x20;cryochamber&#x20;includes&#x20;the&#x20;conduction&#x20;heat&#x20;transfer&#x20;through&#x20;a&#x20;cold&#x20;well,&#x20;the&#x20;gases&#x20;conduction&#x20;and&#x20;gas&#x20;outgassing,&#x20;as&#x20;well&#x20;as&#x20;radiation&#x20;heat&#x20;transfer.&#x20;The&#x20;transient&#x20;cooling&#x20;characteristics&#x20;of&#x20;an&#x20;infrared&#x20;detector&#x20;cryochamber&#x20;are&#x20;investigated&#x20;experimentally&#x20;in&#x20;the&#x20;present&#x20;study.&#x20;The&#x20;transient&#x20;cooling&#x20;load&#x20;increases&#x20;as&#x20;the&#x20;gas&#x20;pressure&#x20;is&#x20;increased.&#x20;Gas&#x20;pressure&#x20;becomes&#x20;significant&#x20;as&#x20;the&#x20;cooling&#x20;process&#x20;proceeds.&#x20;Cool&#x20;down&#x20;time&#x20;is&#x20;also&#x20;increased&#x20;as&#x20;the&#x20;gas&#x20;pressure&#x20;is&#x20;increased.&#x20;It&#x20;is&#x20;also&#x20;found&#x20;that&#x20;natural&#x20;convection&#x20;effects&#x20;on&#x20;cool&#x20;down&#x20;time&#x20;become&#x20;significant&#x20;when&#x20;the&#x20;gas&#x20;pressure&#x20;is&#x20;increased.</dcvalue>
<dcvalue element="publisher" qualifier="none">대한설비공학회</dcvalue>
<dcvalue element="title" qualifier="none">적외선&#x20;센서용&#x20;극저온&#x20;용기의&#x20;냉각특성에&#x20;관한&#x20;실험적&#x20;연구</dcvalue>
<dcvalue element="title" qualifier="alternative">An&#x20;Experimental&#x20;Study&#x20;on&#x20;the&#x20;Cooling&#x20;Characteristics&#x20;of&#x20;an&#x20;Infrared&#x20;Detector&#x20;Cryochamber</dcvalue>
<dcvalue element="type" qualifier="none">Article</dcvalue>
<dcvalue element="description" qualifier="journalClass">2</dcvalue>
<dcvalue element="identifier" qualifier="bibliographicCitation">설비공학&#x20;논문집,&#x20;v.16,&#x20;no.10,&#x20;pp.889&#x20;-&#x20;894</dcvalue>
<dcvalue element="citation" qualifier="title">설비공학&#x20;논문집</dcvalue>
<dcvalue element="citation" qualifier="volume">16</dcvalue>
<dcvalue element="citation" qualifier="number">10</dcvalue>
<dcvalue element="citation" qualifier="startPage">889</dcvalue>
<dcvalue element="citation" qualifier="endPage">894</dcvalue>
<dcvalue element="description" qualifier="journalRegisteredClass">kci</dcvalue>
<dcvalue element="identifier" qualifier="kciid">ART000929786</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">극저온&#x20;용기</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">적외선&#x20;센서</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">과도열전달</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">냉각시간</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Cryochamber</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">IR&#x20;sensor</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Transient&#x20;heat&#x20;transfer</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Cool&#x20;down&#x20;time</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Cryochamber</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">IR&#x20;sensor</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Transient&#x20;heat&#x20;transfer</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Cool&#x20;down&#x20;time</dcvalue>
</dublin_core>