<?xml version="1.0" encoding="utf-8" standalone="no"?>
<dublin_core schema="dc">
<dcvalue element="contributor" qualifier="author">Ji,&#x20;JH</dcvalue>
<dcvalue element="contributor" qualifier="author">Hwang,&#x20;JH</dcvalue>
<dcvalue element="contributor" qualifier="author">Bae,&#x20;GN</dcvalue>
<dcvalue element="contributor" qualifier="author">Kim,&#x20;YG</dcvalue>
<dcvalue element="date" qualifier="accessioned">2024-01-21T07:08:33Z</dcvalue>
<dcvalue element="date" qualifier="available">2024-01-21T07:08:33Z</dcvalue>
<dcvalue element="date" qualifier="created">2021-09-02</dcvalue>
<dcvalue element="date" qualifier="issued">2004-05</dcvalue>
<dcvalue element="identifier" qualifier="issn">0304-3886</dcvalue>
<dcvalue element="identifier" qualifier="uri">https:&#x2F;&#x2F;pubs.kist.re.kr&#x2F;handle&#x2F;201004&#x2F;137637</dcvalue>
<dcvalue element="description" qualifier="abstract">Experiments&#x20;were&#x20;carried&#x20;out&#x20;to&#x20;investigate&#x20;agglomeration&#x20;characteristics&#x20;of&#x20;bipolarly&#x20;charged&#x20;particles&#x20;under&#x20;an&#x20;AC&#x20;electric&#x20;field&#x20;and&#x20;to&#x20;investigate&#x20;charging&#x20;characteristics&#x20;of&#x20;particles&#x20;by&#x20;using&#x20;wire-to-plate&#x20;type&#x20;DC&#x20;corona&#x20;chargers.&#x20;A&#x20;laboratory-scale&#x20;setup&#x20;was&#x20;built&#x20;and&#x20;experiments&#x20;were&#x20;conducted&#x20;at&#x20;laboratory&#x20;conditions.&#x20;The&#x20;effects&#x20;of&#x20;DC&#x20;and&#x20;AC&#x20;fields&#x20;on&#x20;the&#x20;variation&#x20;of&#x20;particle&#x20;size&#x20;distribution&#x20;are&#x20;discussed.&#x20;Bipolar&#x20;voltages&#x20;of&#x20;+&#x20;8&#x20;and&#x20;-8&#x20;kV&#x20;DC&#x20;were&#x20;applied&#x20;to&#x20;the&#x20;two&#x20;corona&#x20;chargers,&#x20;respectively.&#x20;The&#x20;AC&#x20;electric&#x20;field&#x20;applied&#x20;to&#x20;the&#x20;agglomeration&#x20;section&#x20;was&#x20;3.9&#x20;kV&#x2F;cm&#x20;(rms),&#x20;and&#x20;the&#x20;residence&#x20;time&#x20;in&#x20;the&#x20;agglomeration&#x20;section&#x20;was&#x20;adjusted&#x20;to&#x20;1&#x20;s.&#x20;Particle&#x20;size&#x20;distributions&#x20;were&#x20;measured&#x20;with&#x20;a&#x20;cascade&#x20;impactor&#x20;(MOUDI).&#x20;The&#x20;reduction&#x20;ratio&#x20;of&#x20;submicron&#x20;particles&#x20;due&#x20;to&#x20;AC&#x20;fields&#x20;with&#x20;60-500&#x20;Hz&#x20;was&#x20;25-29%.&#x20;The&#x20;average&#x20;number&#x20;of&#x20;elementary&#x20;charge&#x20;per&#x20;particle&#x20;was&#x20;measured&#x20;when&#x20;the&#x20;polarities&#x20;of&#x20;two&#x20;corona&#x20;chargers&#x20;were&#x20;either&#x20;positive&#x20;or&#x20;negative.&#x20;Current&#x2F;voltage&#x20;characteristics&#x20;of&#x20;our&#x20;corona&#x20;chargers&#x20;were&#x20;obtained&#x20;for&#x20;high-mass&#x20;loading&#x20;condition&#x20;and&#x20;compared&#x20;with&#x20;those&#x20;for&#x20;the&#x20;no&#x20;mass&#x20;loading.&#x20;Seventy&#x20;to&#x20;ninety&#x20;percent&#x20;of&#x20;corona-induced&#x20;ions&#x20;were&#x20;intercepted&#x20;by&#x20;DOS&#x20;particles&#x20;in&#x20;the&#x20;negative&#x20;corona&#x20;charger.&#x20;The&#x20;results&#x20;imply&#x20;that&#x20;the&#x20;particle&#x20;charges&#x20;depend&#x20;on&#x20;the&#x20;particle&#x20;mass&#x20;loading,&#x20;i.e.&#x20;higher&#x20;mass&#x20;loading&#x20;will&#x20;cause&#x20;lower&#x20;particle&#x20;charges.&#x20;(C)&#x20;2004&#x20;Elsevier&#x20;B.V.&#x20;All&#x20;rights&#x20;reserved.</dcvalue>
<dcvalue element="language" qualifier="none">English</dcvalue>
<dcvalue element="publisher" qualifier="none">ELSEVIER&#x20;SCIENCE&#x20;BV</dcvalue>
<dcvalue element="title" qualifier="none">Particle&#x20;charging&#x20;and&#x20;agglomeration&#x20;in&#x20;DC&#x20;and&#x20;AC&#x20;electric&#x20;fields</dcvalue>
<dcvalue element="type" qualifier="none">Article</dcvalue>
<dcvalue element="identifier" qualifier="doi">10.1016&#x2F;j.elstat.2003.12.003</dcvalue>
<dcvalue element="description" qualifier="journalClass">1</dcvalue>
<dcvalue element="identifier" qualifier="bibliographicCitation">JOURNAL&#x20;OF&#x20;ELECTROSTATICS,&#x20;v.61,&#x20;no.1,&#x20;pp.57&#x20;-&#x20;68</dcvalue>
<dcvalue element="citation" qualifier="title">JOURNAL&#x20;OF&#x20;ELECTROSTATICS</dcvalue>
<dcvalue element="citation" qualifier="volume">61</dcvalue>
<dcvalue element="citation" qualifier="number">1</dcvalue>
<dcvalue element="citation" qualifier="startPage">57</dcvalue>
<dcvalue element="citation" qualifier="endPage">68</dcvalue>
<dcvalue element="description" qualifier="journalRegisteredClass">scie</dcvalue>
<dcvalue element="description" qualifier="journalRegisteredClass">scopus</dcvalue>
<dcvalue element="identifier" qualifier="wosid">000220833700005</dcvalue>
<dcvalue element="identifier" qualifier="scopusid">2-s2.0-2142766837</dcvalue>
<dcvalue element="relation" qualifier="journalWebOfScienceCategory">Engineering,&#x20;Electrical&#x20;&amp;&#x20;Electronic</dcvalue>
<dcvalue element="relation" qualifier="journalResearchArea">Engineering</dcvalue>
<dcvalue element="type" qualifier="docType">Article</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">AC&#x20;electric&#x20;field</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">bipolarly&#x20;charging</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">electrical&#x20;agglomeration</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">particle&#x20;size&#x20;distribution</dcvalue>
</dublin_core>