<?xml version="1.0" encoding="utf-8" standalone="no"?>
<dublin_core schema="dc">
<dcvalue element="contributor" qualifier="author">Myung,&#x20;SW</dcvalue>
<dcvalue element="contributor" qualifier="author">Yoon,&#x20;SH</dcvalue>
<dcvalue element="contributor" qualifier="author">Kim,&#x20;M</dcvalue>
<dcvalue element="date" qualifier="accessioned">2024-01-21T08:02:26Z</dcvalue>
<dcvalue element="date" qualifier="available">2024-01-21T08:02:26Z</dcvalue>
<dcvalue element="date" qualifier="created">2021-09-01</dcvalue>
<dcvalue element="date" qualifier="issued">2003-12</dcvalue>
<dcvalue element="identifier" qualifier="issn">0003-2654</dcvalue>
<dcvalue element="identifier" qualifier="uri">https:&#x2F;&#x2F;pubs.kist.re.kr&#x2F;handle&#x2F;201004&#x2F;138070</dcvalue>
<dcvalue element="description" qualifier="abstract">An&#x20;automated&#x20;LPME&#x20;device&#x20;for&#x20;a&#x20;dynamic&#x20;LPME&#x20;method&#x20;was&#x20;manufactured&#x20;and&#x20;its&#x20;extraction&#x20;efficiency&#x20;was&#x20;tested&#x20;using&#x20;spiked&#x20;urine&#x20;samples.&#x20;The&#x20;developed&#x20;home-made&#x20;LPME&#x20;device&#x20;was&#x20;a&#x20;programmable&#x20;automated&#x20;syringe&#x20;dispenser&#x20;to&#x20;overcome&#x20;deteriorating&#x20;precision&#x20;and&#x20;difficulties&#x20;in&#x20;manually&#x20;manipulating&#x20;the&#x20;plunger&#x20;repeatedly.&#x20;To&#x20;establish&#x20;the&#x20;optimum&#x20;parameters&#x20;for&#x20;benzene&#x20;ethylamines,&#x20;the&#x20;effects&#x20;of&#x20;sampling&#x20;volume,&#x20;solvent&#x20;volume,&#x20;pH,&#x20;salt-effect,&#x20;choice&#x20;of&#x20;solvents,&#x20;plunger&#x20;speed,&#x20;and&#x20;number&#x20;of&#x20;samplings&#x20;were&#x20;investigated.&#x20;Good&#x20;repeatabilities&#x20;for&#x20;the&#x20;extraction&#x20;of&#x20;mephentermine,&#x20;ephedrine,&#x20;methoxyphenamine,&#x20;selegiline,&#x20;and&#x20;bupropion&#x20;were&#x20;obtained&#x20;and&#x20;the&#x20;RSD&#x20;values&#x20;were&#x20;2.4,&#x20;1.9,&#x20;1.3,&#x20;1.6&#x20;and&#x20;1.5%&#x20;at&#x20;a&#x20;concentration&#x20;of&#x20;3&#x20;mug&#x20;mL(-1)&#x20;in&#x20;spiked&#x20;urine&#x20;samples,&#x20;respectively.&#x20;The&#x20;limit&#x20;of&#x20;detection&#x20;was&#x20;below&#x20;0.05&#x20;mug&#x20;mL(-1)&#x20;for&#x20;the&#x20;investigated&#x20;drugs.&#x20;This&#x20;developed&#x20;device&#x20;for&#x20;LPME&#x20;analysis&#x20;gave&#x20;good&#x20;validation&#x20;results&#x20;and&#x20;improved&#x20;convenience.</dcvalue>
<dcvalue element="language" qualifier="none">English</dcvalue>
<dcvalue element="publisher" qualifier="none">ROYAL&#x20;SOC&#x20;CHEMISTRY</dcvalue>
<dcvalue element="subject" qualifier="none">CHROMATOGRAPHY-MASS-SPECTROMETRY</dcvalue>
<dcvalue element="subject" qualifier="none">GAS-CHROMATOGRAPHY</dcvalue>
<dcvalue element="subject" qualifier="none">CONVENTIONAL&#x20;MICROSYRINGE</dcvalue>
<dcvalue element="title" qualifier="none">Analysis&#x20;of&#x20;benzene&#x20;ethylamine&#x20;derivatives&#x20;in&#x20;urine&#x20;using&#x20;the&#x20;programmable&#x20;dynamic&#x20;liquid-phase&#x20;microextraction&#x20;(LPME)&#x20;device</dcvalue>
<dcvalue element="type" qualifier="none">Article</dcvalue>
<dcvalue element="identifier" qualifier="doi">10.1039&#x2F;b312227c</dcvalue>
<dcvalue element="description" qualifier="journalClass">1</dcvalue>
<dcvalue element="identifier" qualifier="bibliographicCitation">ANALYST,&#x20;v.128,&#x20;no.12,&#x20;pp.1443&#x20;-&#x20;1446</dcvalue>
<dcvalue element="citation" qualifier="title">ANALYST</dcvalue>
<dcvalue element="citation" qualifier="volume">128</dcvalue>
<dcvalue element="citation" qualifier="number">12</dcvalue>
<dcvalue element="citation" qualifier="startPage">1443</dcvalue>
<dcvalue element="citation" qualifier="endPage">1446</dcvalue>
<dcvalue element="description" qualifier="journalRegisteredClass">scie</dcvalue>
<dcvalue element="description" qualifier="journalRegisteredClass">scopus</dcvalue>
<dcvalue element="identifier" qualifier="wosid">000187000500008</dcvalue>
<dcvalue element="identifier" qualifier="scopusid">2-s2.0-0347722503</dcvalue>
<dcvalue element="relation" qualifier="journalWebOfScienceCategory">Chemistry,&#x20;Analytical</dcvalue>
<dcvalue element="relation" qualifier="journalResearchArea">Chemistry</dcvalue>
<dcvalue element="type" qualifier="docType">Article</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">CHROMATOGRAPHY-MASS-SPECTROMETRY</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">GAS-CHROMATOGRAPHY</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">CONVENTIONAL&#x20;MICROSYRINGE</dcvalue>