<?xml version="1.0" encoding="utf-8" standalone="no"?>
<dublin_core schema="dc">
<dcvalue element="contributor" qualifier="author">Baik,&#x20;YJ</dcvalue>
<dcvalue element="contributor" qualifier="author">Chang,&#x20;YS</dcvalue>
<dcvalue element="contributor" qualifier="author">Kim,&#x20;Y</dcvalue>
<dcvalue element="date" qualifier="accessioned">2024-01-21T13:12:56Z</dcvalue>
<dcvalue element="date" qualifier="available">2024-01-21T13:12:56Z</dcvalue>
<dcvalue element="date" qualifier="created">2021-09-05</dcvalue>
<dcvalue element="date" qualifier="issued">2000-11</dcvalue>
<dcvalue element="identifier" qualifier="issn">1340-8054</dcvalue>
<dcvalue element="identifier" qualifier="uri">https:&#x2F;&#x2F;pubs.kist.re.kr&#x2F;handle&#x2F;201004&#x2F;140975</dcvalue>
<dcvalue element="description" qualifier="abstract">In&#x20;this&#x20;study,&#x20;in-situ&#x20;performance&#x20;test&#x20;of&#x20;a&#x20;20&#x20;RT&#x20;(70&#x20;kW)&#x20;air-to-air&#x20;heat&#x20;pump&#x20;which&#x20;has&#x20;a&#x20;feature&#x20;of&#x20;recovering&#x20;ventilation&#x20;energy&#x20;is&#x20;carried&#x20;out.&#x20;Since&#x20;test&#x20;conditions&#x20;such&#x20;as&#x20;indoor&#x20;and&#x20;outdoor&#x20;air&#x20;conditions&#x20;cannot&#x20;be&#x20;controlled&#x20;to&#x20;satisfy&#x20;the&#x20;standard&#x20;test&#x20;conditions,&#x20;experiments&#x20;are&#x20;done&#x20;with&#x20;the&#x20;inlet&#x20;air&#x20;conditions&#x20;as&#x20;they&#x20;exist.&#x20;From&#x20;the&#x20;experimental&#x20;data&#x20;obtained&#x20;with&#x20;the&#x20;non-standard&#x20;test&#x20;conditions,&#x20;simulation&#x20;program&#x20;is&#x20;developed&#x20;to&#x20;estimate&#x20;the&#x20;performance&#x20;of&#x20;standard&#x20;test&#x20;conditions.&#x20;The&#x20;map-based&#x20;compressor&#x20;model,&#x20;epsilon&#x20;-NTU&#x20;method&#x20;with&#x20;the&#x20;assumption&#x20;of&#x20;refrigerant-side&#x20;mixed&#x20;and&#x20;air-side&#x20;unmixed&#x20;and&#x20;necessary&#x20;parameters&#x20;determined&#x20;from&#x20;the&#x20;measurements&#x20;are&#x20;used.&#x20;From&#x20;the&#x20;simulation,&#x20;performance&#x20;of&#x20;a&#x20;large&#x20;capacity&#x20;air&#x20;source&#x20;heat&#x20;pump&#x20;for&#x20;various&#x20;conditions&#x20;and&#x20;effects&#x20;of&#x20;ventilation&#x20;are&#x20;calculated.&#x20;This&#x20;study&#x20;provides&#x20;method&#x20;of&#x20;predicting&#x20;the&#x20;performance&#x20;of&#x20;air&#x20;source&#x20;heat&#x20;pumps&#x20;in&#x20;which&#x20;in-situ&#x20;performance&#x20;test&#x20;is&#x20;necessary.</dcvalue>
<dcvalue element="language" qualifier="none">English</dcvalue>
<dcvalue element="publisher" qualifier="none">JAPAN&#x20;SOC&#x20;MECHANICAL&#x20;ENGINEERS</dcvalue>
<dcvalue element="subject" qualifier="none">FLOW</dcvalue>
<dcvalue element="title" qualifier="none">In-situ&#x20;performance&#x20;test&#x20;and&#x20;simulation&#x20;of&#x20;an&#x20;air&#x20;source&#x20;heat&#x20;pump</dcvalue>
<dcvalue element="type" qualifier="none">Article</dcvalue>
<dcvalue element="description" qualifier="journalClass">1</dcvalue>
<dcvalue element="identifier" qualifier="bibliographicCitation">JSME&#x20;INTERNATIONAL&#x20;JOURNAL&#x20;SERIES&#x20;B-FLUIDS&#x20;AND&#x20;THERMAL&#x20;ENGINEERING,&#x20;v.43,&#x20;no.4,&#x20;pp.628&#x20;-&#x20;633</dcvalue>
<dcvalue element="citation" qualifier="title">JSME&#x20;INTERNATIONAL&#x20;JOURNAL&#x20;SERIES&#x20;B-FLUIDS&#x20;AND&#x20;THERMAL&#x20;ENGINEERING</dcvalue>
<dcvalue element="citation" qualifier="volume">43</dcvalue>
<dcvalue element="citation" qualifier="number">4</dcvalue>
<dcvalue element="citation" qualifier="startPage">628</dcvalue>
<dcvalue element="citation" qualifier="endPage">633</dcvalue>
<dcvalue element="description" qualifier="journalRegisteredClass">scie</dcvalue>
<dcvalue element="description" qualifier="journalRegisteredClass">scopus</dcvalue>
<dcvalue element="identifier" qualifier="wosid">000166154800017</dcvalue>
<dcvalue element="identifier" qualifier="scopusid">2-s2.0-0034313668</dcvalue>
<dcvalue element="relation" qualifier="journalWebOfScienceCategory">Thermodynamics</dcvalue>
<dcvalue element="relation" qualifier="journalWebOfScienceCategory">Engineering,&#x20;Mechanical</dcvalue>
<dcvalue element="relation" qualifier="journalResearchArea">Thermodynamics</dcvalue>
<dcvalue element="relation" qualifier="journalResearchArea">Engineering</dcvalue>
<dcvalue element="type" qualifier="docType">Article;&#x20;Proceedings&#x20;Paper</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">FLOW</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">air&#x20;source</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">heat&#x20;pump</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">in-situ&#x20;performance&#x20;test</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">simulation</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">ventilation&#x20;energy&#x20;recovery</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">map-based&#x20;compressor&#x20;model</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">heat&#x20;exchanger</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">epsilon-NTU</dcvalue>
</dublin_core>