<?xml version="1.0" encoding="utf-8" standalone="no"?>
<dublin_core schema="dc">
<dcvalue element="contributor" qualifier="author">Jeong,&#x20;S</dcvalue>
<dcvalue element="contributor" qualifier="author">Kang,&#x20;BH</dcvalue>
<dcvalue element="contributor" qualifier="author">Karng,&#x20;SW</dcvalue>
<dcvalue element="date" qualifier="accessioned">2024-01-21T17:42:31Z</dcvalue>
<dcvalue element="date" qualifier="available">2024-01-21T17:42:31Z</dcvalue>
<dcvalue element="date" qualifier="created">2021-09-01</dcvalue>
<dcvalue element="date" qualifier="issued">1998-01</dcvalue>
<dcvalue element="identifier" qualifier="issn">1359-4311</dcvalue>
<dcvalue element="identifier" qualifier="uri">https:&#x2F;&#x2F;pubs.kist.re.kr&#x2F;handle&#x2F;201004&#x2F;143446</dcvalue>
<dcvalue element="description" qualifier="abstract">Numerical&#x20;simulation&#x20;was&#x20;carried&#x20;out&#x20;to&#x20;predict&#x20;the&#x20;transient&#x20;operating&#x20;characteristics&#x20;and&#x20;performance&#x20;of&#x20;an&#x20;absorption&#x20;heat&#x20;pump&#x20;recovering&#x20;waste&#x20;heat&#x20;of&#x20;30&#x20;degrees&#x20;C-40&#x20;degrees&#x20;C.&#x20;The&#x20;effects&#x20;of&#x20;the&#x20;temperature&#x20;and&#x20;the&#x20;mass&#x20;how&#x20;rate&#x20;of&#x20;the&#x20;heat&#x20;transfer&#x20;medium,&#x20;the&#x20;heat&#x20;transfer&#x20;area&#x20;of&#x20;the&#x20;system&#x20;components,&#x20;and&#x20;the&#x20;solution&#x20;circulation&#x20;rate&#x20;on&#x20;the&#x20;system&#x20;performance&#x20;are&#x20;investigated&#x20;in&#x20;detail.&#x20;The&#x20;results&#x20;obtained&#x20;indicate&#x20;that&#x20;a&#x20;higher&#x20;heating&#x20;capacity&#x20;is&#x20;obtained&#x20;with&#x20;an&#x20;increase&#x20;in&#x20;driving&#x20;steam&#x20;temperature,&#x20;waste&#x20;heat&#x20;temperature,&#x20;and&#x20;mass&#x20;flow&#x20;rate&#x20;of&#x20;hot&#x20;water&#x20;and&#x20;waste&#x20;water.&#x20;It&#x20;is&#x20;also&#x20;found&#x20;that&#x20;the&#x20;heating&#x20;capacity&#x20;becomes&#x20;higher&#x20;with&#x20;an&#x20;increase&#x20;in&#x20;heat&#x20;transfer&#x20;area&#x20;of&#x20;the&#x20;system&#x20;components&#x20;except&#x20;solution&#x20;heat&#x20;exchanger.&#x20;An&#x20;increase&#x20;in&#x20;solution&#x20;Row&#x20;rate&#x20;leads&#x20;to&#x20;higher&#x20;heating&#x20;capacity&#x20;but&#x20;to&#x20;lower&#x20;COP.&#x20;A&#x20;practical&#x20;absorption&#x20;heat&#x20;pump,&#x20;installed&#x20;at&#x20;a&#x20;chemical&#x20;plant,&#x20;was&#x20;also&#x20;simulated&#x20;numerically.&#x20;The&#x20;simulation&#x20;results&#x20;were&#x20;compared&#x20;with&#x20;the&#x20;operation&#x20;data&#x20;of&#x20;the&#x20;practical&#x20;system.&#x20;(C)&#x20;1997&#x20;Published&#x20;by&#x20;Elsevier&#x20;Science&#x20;Ltd.</dcvalue>
<dcvalue element="language" qualifier="none">English</dcvalue>
<dcvalue element="publisher" qualifier="none">PERGAMON-ELSEVIER&#x20;SCIENCE&#x20;LTD</dcvalue>
<dcvalue element="title" qualifier="none">Dynamic&#x20;simulation&#x20;of&#x20;an&#x20;absorption&#x20;heat&#x20;pump&#x20;for&#x20;recovering&#x20;low&#x20;grade&#x20;waste&#x20;heat</dcvalue>
<dcvalue element="type" qualifier="none">Article</dcvalue>
<dcvalue element="identifier" qualifier="doi">10.1016&#x2F;S1359-4311(97)00040-9</dcvalue>
<dcvalue element="description" qualifier="journalClass">1</dcvalue>
<dcvalue element="identifier" qualifier="bibliographicCitation">APPLIED&#x20;THERMAL&#x20;ENGINEERING,&#x20;v.18,&#x20;no.1-2,&#x20;pp.1&#x20;-&#x20;12</dcvalue>
<dcvalue element="citation" qualifier="title">APPLIED&#x20;THERMAL&#x20;ENGINEERING</dcvalue>
<dcvalue element="citation" qualifier="volume">18</dcvalue>
<dcvalue element="citation" qualifier="number">1-2</dcvalue>
<dcvalue element="citation" qualifier="startPage">1</dcvalue>
<dcvalue element="citation" qualifier="endPage">12</dcvalue>
<dcvalue element="description" qualifier="journalRegisteredClass">scie</dcvalue>
<dcvalue element="description" qualifier="journalRegisteredClass">scopus</dcvalue>
<dcvalue element="identifier" qualifier="wosid">000071498800001</dcvalue>
<dcvalue element="identifier" qualifier="scopusid">2-s2.0-0031630347</dcvalue>
<dcvalue element="relation" qualifier="journalWebOfScienceCategory">Thermodynamics</dcvalue>
<dcvalue element="relation" qualifier="journalWebOfScienceCategory">Energy&#x20;&amp;&#x20;Fuels</dcvalue>
<dcvalue element="relation" qualifier="journalWebOfScienceCategory">Engineering,&#x20;Mechanical</dcvalue>
<dcvalue element="relation" qualifier="journalWebOfScienceCategory">Mechanics</dcvalue>
<dcvalue element="relation" qualifier="journalResearchArea">Thermodynamics</dcvalue>
<dcvalue element="relation" qualifier="journalResearchArea">Energy&#x20;&amp;&#x20;Fuels</dcvalue>
<dcvalue element="relation" qualifier="journalResearchArea">Engineering</dcvalue>
<dcvalue element="relation" qualifier="journalResearchArea">Mechanics</dcvalue>
<dcvalue element="type" qualifier="docType">Article</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">numerical&#x20;simulation</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">absorption&#x20;heat&#x20;pump</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">waste&#x20;heat&#x20;recovery</dcvalue>
</dublin_core>
