<?xml version="1.0" encoding="utf-8" standalone="no"?>
<dublin_core schema="dc">
<dcvalue element="contributor" qualifier="author">Choi,&#x20;Junhyuk</dcvalue>
<dcvalue element="contributor" qualifier="author">Kim,&#x20;Hyungmin</dcvalue>
<dcvalue element="contributor" qualifier="author">Choi,&#x20;Junho</dcvalue>
<dcvalue element="contributor" qualifier="author">Lee,&#x20;Jong&#x20;Min</dcvalue>
<dcvalue element="contributor" qualifier="author">Choi,&#x20;Taejin</dcvalue>
<dcvalue element="contributor" qualifier="author">Kim,&#x20;Seung-Jong</dcvalue>
<dcvalue element="contributor" qualifier="author">Chun,&#x20;Min&#x20;Ho</dcvalue>
<dcvalue element="date" qualifier="accessioned">2025-07-18T09:01:43Z</dcvalue>
<dcvalue element="date" qualifier="available">2025-07-18T09:01:43Z</dcvalue>
<dcvalue element="date" qualifier="created">2025-07-18</dcvalue>
<dcvalue element="date" qualifier="issued">2025-11</dcvalue>
<dcvalue element="identifier" qualifier="issn">2234-7593</dcvalue>
<dcvalue element="identifier" qualifier="uri">https:&#x2F;&#x2F;pubs.kist.re.kr&#x2F;handle&#x2F;201004&#x2F;152827</dcvalue>
<dcvalue element="description" qualifier="abstract">The&#x20;purpose&#x20;of&#x20;this&#x20;paper&#x20;is&#x20;to&#x20;introduce&#x20;an&#x20;EMG-based&#x20;real-time&#x20;gait&#x20;speed&#x20;control&#x20;algorithm&#x20;embedded&#x20;robot-assisted&#x20;gait&#x20;training&#x20;(RAGT)&#x20;system&#x20;for&#x20;gait&#x20;rehabilitation&#x20;of&#x20;post-stroke&#x20;hemiparetic&#x20;patients&#x20;and&#x20;to&#x20;verify&#x20;its&#x20;feasibility&#x20;and&#x20;safety.&#x20;According&#x20;to&#x20;the&#x20;previous&#x20;researches,&#x20;the&#x20;gait&#x20;speed&#x20;of&#x20;ongoing&#x20;step&#x20;is&#x20;linearly&#x20;proportional&#x20;to&#x20;the&#x20;maximum&#x20;value&#x20;of&#x20;Soleus&#x20;electromyogram&#x20;(EMG)&#x20;waveform&#x20;length&#x20;(WL)&#x20;in&#x20;the&#x20;prior&#x20;gait&#x20;cycle.&#x20;This&#x20;tendency&#x20;was&#x20;observed&#x20;not&#x20;only&#x20;on&#x20;healthy&#x20;people&#x20;or&#x20;the&#x20;nonparetic&#x20;side&#x20;leg&#x20;of&#x20;post-stroke&#x20;hemiparetic&#x20;patients,&#x20;but&#x20;also&#x20;on&#x20;the&#x20;affected&#x20;side&#x20;leg.&#x20;Therefore,&#x20;we&#x20;developed&#x20;an&#x20;algorithm&#x20;that&#x20;can&#x20;control&#x20;the&#x20;gait&#x20;speed&#x20;according&#x20;to&#x20;the&#x20;magnitude&#x20;of&#x20;Soleus&#x20;EMG&#x20;signal&#x20;and&#x20;embeded&#x20;it&#x20;to&#x20;a&#x20;lower-limb&#x20;exoskeleton&#x20;to&#x20;design&#x20;task-oriented&#x20;RAGT&#x20;to&#x20;improve&#x20;effectiveness&#x20;of&#x20;gait&#x20;rehabilitation&#x20;for&#x20;hemipatic&#x20;patients&#x20;in&#x20;subacute&#x20;phase.&#x20;Firstly,&#x20;we&#x20;applied&#x20;it&#x20;to&#x20;post-stroke&#x20;patients&#x20;in&#x20;chronic&#x20;phase.&#x20;A&#x20;total&#x20;of&#x20;30&#x20;patients&#x20;were&#x20;participated&#x20;and&#x20;divided&#x20;into&#x20;the&#x20;following&#x20;three&#x20;groups:&#x20;constant&#x20;gait&#x20;speed&#x20;RAGT&#x20;Group&#x20;A,&#x20;EMG-based&#x20;gait&#x20;speed-controlled&#x20;RAGT&#x20;Group&#x20;B,&#x20;and&#x20;traditional&#x20;gait&#x20;training&#x20;Group&#x20;C.&#x20;All&#x20;subjects&#x20;safely&#x20;completed&#x20;a&#x20;total&#x20;of&#x20;10&#x20;days&#x20;of&#x20;gait&#x20;training&#x20;protocol,&#x20;approximately&#x20;30&#x20;min&#x2F;day,&#x20;2-3&#x20;days&#x20;apart.&#x20;Gait&#x20;performance&#x20;was&#x20;measured&#x20;before&#x20;and&#x20;after&#x20;the&#x20;training.&#x20;The&#x20;result&#x20;showed&#x20;the&#x20;EMG&#x20;WL&#x20;in&#x20;Group&#x20;B&#x20;was&#x20;significantly&#x20;increased.&#x20;In&#x20;this&#x20;study,&#x20;we&#x20;proposed&#x20;a&#x20;novel&#x20;RAGT&#x20;system&#x20;with&#x20;EMG-based&#x20;gait&#x20;speed&#x20;feedback&#x20;and&#x20;verified.&#x20;The&#x20;results&#x20;confirmed&#x20;its&#x20;applicability&#x20;with&#x20;safety&#x20;and&#x20;in&#x20;future&#x20;clinical&#x20;research&#x20;with&#x20;patients&#x20;who&#x20;require&#x20;gait&#x20;rehabilitation&#x20;after&#x20;stroke.</dcvalue>
<dcvalue element="language" qualifier="none">English</dcvalue>
<dcvalue element="publisher" qualifier="none">한국정밀공학회</dcvalue>
<dcvalue element="title" qualifier="none">EMG-Based&#x20;Gait&#x20;Speed&#x20;Control&#x20;of&#x20;a&#x20;Lower-limb&#x20;Exoskeleton&#x20;for&#x20;Gait&#x20;Rehabilitation:&#x20;A&#x20;Proof-of-Concept&#x20;Study&#x20;with&#x20;Post-stroke&#x20;Chronic&#x20;Hemiparetic&#x20;Patients</dcvalue>
<dcvalue element="type" qualifier="none">Article</dcvalue>
<dcvalue element="identifier" qualifier="doi">10.1007&#x2F;s12541-025-01274-x</dcvalue>
<dcvalue element="description" qualifier="journalClass">1</dcvalue>
<dcvalue element="identifier" qualifier="bibliographicCitation">International&#x20;Journal&#x20;of&#x20;Precision&#x20;Engineering&#x20;and&#x20;Manufacturing,&#x20;v.26,&#x20;no.11,&#x20;pp.3059&#x20;-&#x20;3067</dcvalue>
<dcvalue element="citation" qualifier="title">International&#x20;Journal&#x20;of&#x20;Precision&#x20;Engineering&#x20;and&#x20;Manufacturing</dcvalue>
<dcvalue element="citation" qualifier="volume">26</dcvalue>
<dcvalue element="citation" qualifier="number">11</dcvalue>
<dcvalue element="citation" qualifier="startPage">3059</dcvalue>
<dcvalue element="citation" qualifier="endPage">3067</dcvalue>
<dcvalue element="description" qualifier="isOpenAccess">N</dcvalue>
<dcvalue element="description" qualifier="journalRegisteredClass">scie</dcvalue>
<dcvalue element="description" qualifier="journalRegisteredClass">scopus</dcvalue>
<dcvalue element="description" qualifier="journalRegisteredClass">kci</dcvalue>
<dcvalue element="identifier" qualifier="wosid">001512775300001</dcvalue>
<dcvalue element="relation" qualifier="journalWebOfScienceCategory">Engineering,&#x20;Manufacturing</dcvalue>
<dcvalue element="relation" qualifier="journalWebOfScienceCategory">Engineering,&#x20;Mechanical</dcvalue>
<dcvalue element="relation" qualifier="journalResearchArea">Engineering</dcvalue>
<dcvalue element="type" qualifier="docType">Article</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">MOTOR&#x20;REHABILITATION</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">STROKE</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">RECOVERY</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Robot&#x20;assist&#x20;gait&#x20;training</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Post-stroke&#x20;hemiparetic&#x20;patient</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Gait&#x20;rehabilitation</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Plantar&#x20;flexor&#x20;EMG</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Gait&#x20;Speed</dcvalue>
</dublin_core>
