<?xml version="1.0" encoding="utf-8" standalone="no"?>
<dublin_core schema="dc">
<dcvalue element="contributor" qualifier="author">Lee,&#x20;Jiyong</dcvalue>
<dcvalue element="contributor" qualifier="author">Kim,&#x20;Kanggeon</dcvalue>
<dcvalue element="contributor" qualifier="author">You,&#x20;Bum-Jae</dcvalue>
<dcvalue element="date" qualifier="accessioned">2025-09-23T03:02:37Z</dcvalue>
<dcvalue element="date" qualifier="available">2025-09-23T03:02:37Z</dcvalue>
<dcvalue element="date" qualifier="created">2025-09-16</dcvalue>
<dcvalue element="date" qualifier="issued">2025-10</dcvalue>
<dcvalue element="identifier" qualifier="uri">https:&#x2F;&#x2F;pubs.kist.re.kr&#x2F;handle&#x2F;201004&#x2F;153221</dcvalue>
<dcvalue element="description" qualifier="abstract">Kinematic&#x20;and&#x20;hand-eye&#x20;calibration&#x20;of&#x20;robotic&#x20;arms&#x20;is&#x20;a&#x20;critical&#x20;research&#x20;area&#x20;in&#x20;robotics,&#x20;essential&#x20;to&#x20;ensuring&#x20;the&#x20;accuracy&#x20;of&#x20;manipulation&#x20;tasks.&#x20;The&#x20;widely&#x20;adopted&#x20;methods&#x20;for&#x20;robotic&#x20;arm&#x20;calibration&#x20;typically&#x20;rely&#x20;on&#x20;specialized&#x20;markers&#x20;or&#x20;external&#x20;sensors&#x20;to&#x20;achieve&#x20;precise&#x20;measurements.&#x20;However,&#x20;these&#x20;approaches&#x20;are&#x20;often&#x20;expensive&#x20;and&#x20;require&#x20;additional&#x20;effort,&#x20;such&#x20;as&#x20;the&#x20;installation&#x20;and&#x20;maintenance&#x20;of&#x20;auxiliary&#x20;equipment.&#x20;Furthermore,&#x20;many&#x20;downstream&#x20;tasks&#x20;require&#x20;separate&#x20;hand-eye&#x20;calibration&#x20;steps&#x20;because&#x20;of&#x20;differences&#x20;between&#x20;the&#x20;sensors&#x20;used&#x20;for&#x20;calibration&#x20;and&#x20;those&#x20;used&#x20;for&#x20;task&#x20;execution.&#x20;Comprehensive&#x20;calibration&#x20;of&#x20;both&#x20;the&#x20;robot&#x20;arm&#x20;and&#x20;sensors&#x20;plays&#x20;a&#x20;vital&#x20;role&#x20;in&#x20;optimizing&#x20;system&#x20;performance.&#x20;However,&#x20;the&#x20;robot&amp;apos;s&#x20;posture&#x20;could&#x20;be&#x20;constrained&#x20;due&#x20;to&#x20;either&#x20;the&#x20;sensor&amp;apos;s&#x20;limited&#x20;range&#x20;or&#x20;textureless&#x20;scenes&#x20;when&#x20;a&#x20;camera&#x20;is&#x20;used.&#x20;To&#x20;address&#x20;these&#x20;limitations,&#x20;this&#x20;study&#x20;proposes&#x20;a&#x20;cost-effective&#x20;self-calibration&#x20;method&#x20;that&#x20;simultaneously&#x20;calibrates&#x20;the&#x20;robot&#x20;arm&#x20;and&#x20;determines&#x20;the&#x20;spatial&#x20;relationship&#x20;between&#x20;the&#x20;robot&#x20;and&#x20;an&#x20;RGB-D&#x20;camera,&#x20;allowing&#x20;for&#x20;data&#x20;collection&#x20;at&#x20;multiple&#x20;locations.&#x20;The&#x20;proposed&#x20;approach&#x20;leverages&#x20;recent&#x20;advancements&#x20;in&#x20;machine&#x20;learning&#x20;to&#x20;identify&#x20;correspondences&#x20;between&#x20;images&#x20;captured&#x20;at&#x20;different&#x20;robot&#x20;postures,&#x20;facilitating&#x20;automatic&#x20;data&#x20;selection.&#x20;Furthermore,&#x20;the&#x20;removal&#x20;of&#x20;location&#x20;constraints&#x20;increases&#x20;flexibility,&#x20;enabling&#x20;the&#x20;collection&#x20;of&#x20;sufficient&#x20;data&#x20;as&#x20;the&#x20;robot&amp;apos;s&#x20;location&#x20;changes.&#x20;The&#x20;method&#x20;is&#x20;evaluated&#x20;using&#x20;a&#x20;Franka&#x20;Emika&#x20;Panda&#x20;robotic&#x20;arm,&#x20;and&#x20;the&#x20;experimental&#x20;results&#x20;demonstrate&#x20;its&#x20;effectiveness&#x20;in&#x20;achieving&#x20;accurate&#x20;calibration&#x20;without&#x20;the&#x20;need&#x20;for&#x20;external&#x20;devices&#x20;or&#x20;markers.</dcvalue>
<dcvalue element="language" qualifier="none">English</dcvalue>
<dcvalue element="publisher" qualifier="none">Institute&#x20;of&#x20;Electrical&#x20;and&#x20;Electronics&#x20;Engineers&#x20;Inc.</dcvalue>
<dcvalue element="title" qualifier="none">Robot&#x20;Arm&#x20;Self-Calibration&#x20;Using&#x20;RGB-D&#x20;Camera</dcvalue>
<dcvalue element="type" qualifier="none">Article</dcvalue>
<dcvalue element="identifier" qualifier="doi">10.1109&#x2F;LRA.2025.3600169</dcvalue>
<dcvalue element="description" qualifier="journalClass">1</dcvalue>
<dcvalue element="identifier" qualifier="bibliographicCitation">IEEE&#x20;Robotics&#x20;and&#x20;Automation&#x20;Letters,&#x20;v.10,&#x20;no.10,&#x20;pp.10258&#x20;-&#x20;10265</dcvalue>
<dcvalue element="citation" qualifier="title">IEEE&#x20;Robotics&#x20;and&#x20;Automation&#x20;Letters</dcvalue>
<dcvalue element="citation" qualifier="volume">10</dcvalue>
<dcvalue element="citation" qualifier="number">10</dcvalue>
<dcvalue element="citation" qualifier="startPage">10258</dcvalue>
<dcvalue element="citation" qualifier="endPage">10265</dcvalue>
<dcvalue element="description" qualifier="isOpenAccess">N</dcvalue>
<dcvalue element="description" qualifier="journalRegisteredClass">scie</dcvalue>
<dcvalue element="description" qualifier="journalRegisteredClass">scopus</dcvalue>
<dcvalue element="identifier" qualifier="wosid">001560192400010</dcvalue>
<dcvalue element="identifier" qualifier="scopusid">2-s2.0-105014197146</dcvalue>
<dcvalue element="relation" qualifier="journalWebOfScienceCategory">Robotics</dcvalue>
<dcvalue element="relation" qualifier="journalResearchArea">Robotics</dcvalue>
<dcvalue element="type" qualifier="docType">Article</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Calibration&#x20;and&#x20;identification</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">computer&#x20;vision&#x20;for&#x20;automation</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">Calibration&#x20;and&#x20;identification</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">computer&#x20;vision&#x20;for&#x20;automation</dcvalue>
</dublin_core>
