<?xml version="1.0" encoding="utf-8" standalone="no"?>
<dublin_core schema="dc">
<dcvalue element="contributor" qualifier="author">Kim,&#x20;Yongsoo</dcvalue>
<dcvalue element="contributor" qualifier="author">Lee,&#x20;Jung-woo</dcvalue>
<dcvalue element="contributor" qualifier="author">Lee,&#x20;Byung&#x20;Chul</dcvalue>
<dcvalue element="contributor" qualifier="author">Seo,&#x20;Hyunseok</dcvalue>
<dcvalue element="date" qualifier="accessioned">2025-11-06T05:31:27Z</dcvalue>
<dcvalue element="date" qualifier="available">2025-11-06T05:31:27Z</dcvalue>
<dcvalue element="date" qualifier="created">2025-11-06</dcvalue>
<dcvalue element="date" qualifier="issued">2025-11</dcvalue>
<dcvalue element="identifier" qualifier="issn">0094-2405</dcvalue>
<dcvalue element="identifier" qualifier="uri">https:&#x2F;&#x2F;pubs.kist.re.kr&#x2F;handle&#x2F;201004&#x2F;153405</dcvalue>
<dcvalue element="description" qualifier="abstract">Background&#x20;It&#x20;is&#x20;easy&#x20;to&#x20;find&#x20;computed&#x20;tomography&#x20;(CT)&#x20;images&#x20;that&#x20;include&#x20;metals&#x20;such&#x20;as&#x20;implants,&#x20;bone&#x20;plates,&#x20;and&#x20;bone&#x20;shafts.&#x20;These&#x20;metals&#x20;replacing&#x20;body&#x20;parts,&#x20;cause&#x20;serious&#x20;artifacts&#x20;in&#x20;the&#x20;CT&#x20;image&#x20;originated&#x20;by&#x20;x-ray&#x20;beam-hardening.&#x20;Traditionally,&#x20;CT&#x20;physics-based&#x20;image&#x20;processing&#x20;techniques&#x20;were&#x20;empirically&#x20;applied&#x20;to&#x20;reduce&#x20;metal&#x20;artifacts&#x20;(MAs).&#x20;Recently,&#x20;with&#x20;the&#x20;great&#x20;success&#x20;of&#x20;deep&#x20;learning,&#x20;many&#x20;studies&#x20;on&#x20;metal&#x20;artifact&#x20;reduction&#x20;(MAR)&#x20;using&#x20;convolutional&#x20;neural&#x20;networks&#x20;(CNNs)&#x20;have&#x20;been&#x20;introduced.&#x20;Purpose&#x20;Most&#x20;of&#x20;them&#x20;commonly&#x20;meet&#x20;a&#x20;challenge&#x20;to&#x20;obtain&#x20;ground&#x20;truth&#x20;images&#x20;for&#x20;MAR&#x20;in&#x20;clinical&#x20;practice.&#x20;Thus,&#x20;for&#x20;effective&#x20;MAR&#x20;without&#x20;ground&#x20;truth&#x20;images,&#x20;we&#x20;propose&#x20;a&#x20;residual&#x20;MA&#x20;model&#x20;for&#x20;unsupervised&#x20;deep&#x20;learning&#x20;scheme&#x20;in&#x20;CT&#x20;images.Methods&#x20;In&#x20;the&#x20;1st&#x20;stage,&#x20;MAs&#x20;are&#x20;extracted&#x20;by&#x20;CT&#x20;physics-inspired&#x20;residual&#x20;model,&#x20;which&#x20;is&#x20;enabled&#x20;by&#x20;the&#x20;residual&#x20;learning&#x20;scheme.&#x20;The&#x20;result&#x20;of&#x20;the&#x20;1st&#x20;stage&#x20;is&#x20;fed&#x20;into&#x20;the&#x20;input&#x20;for&#x20;the&#x20;2nd&#x20;stage,&#x20;where&#x20;artifacts&#x20;that&#x20;are&#x20;not&#x20;reduced&#x20;enough&#x20;in&#x20;the&#x20;1st&#x20;stage&#x20;are&#x20;further&#x20;removed&#x20;by&#x20;the&#x20;contrastive&#x20;learning&#x20;scheme.&#x20;Then,&#x20;the&#x20;networks&#x20;in&#x20;the&#x20;2nd&#x20;stage&#x20;can&#x20;easily&#x20;recognize&#x20;the&#x20;original&#x20;structures&#x20;due&#x20;to&#x20;primary&#x20;artifact&#x20;reduction&#x20;in&#x20;the&#x20;1st&#x20;stage&#x20;and&#x20;can&#x20;properly&#x20;refine&#x20;the&#x20;image.Results&#x20;Our&#x20;model&#x20;was&#x20;validated&#x20;on&#x20;three&#x20;datasets.&#x20;The&#x20;results&#x20;show&#x20;that&#x20;the&#x20;proposed&#x20;model&#x20;outperforms&#x20;other&#x20;MAR&#x20;models,&#x20;preserving&#x20;both&#x20;original&#x20;body&#x20;and&#x20;metal&#x20;structures&#x20;while&#x20;reducing&#x20;MAs&#x20;effectively.Conclusions&#x20;We&#x20;hope&#x20;that&#x20;this&#x20;unsupervised&#x20;learning&#x20;model&#x20;can&#x20;contribute&#x20;to&#x20;good&#x20;achievements&#x20;in&#x20;the&#x20;MAR&#x20;field&#x20;while&#x20;overcoming&#x20;the&#x20;limitations&#x20;of&#x20;data&#x20;construction.</dcvalue>
<dcvalue element="language" qualifier="none">English</dcvalue>
<dcvalue element="publisher" qualifier="none">American&#x20;Association&#x20;of&#x20;Physicists&#x20;in&#x20;Medicine</dcvalue>
<dcvalue element="title" qualifier="none">Residual&#x20;Metal&#x20;Artifact&#x20;Reduction&#x20;in&#x20;CT&#x20;Images:&#x20;An&#x20;Unsupervised&#x20;Residual&#x20;and&#x20;Contrastive&#x20;Learning&#x20;Approach&#x20;for&#x20;Preserving&#x20;Metal&#x20;Structures</dcvalue>
<dcvalue element="type" qualifier="none">Article</dcvalue>
<dcvalue element="identifier" qualifier="doi">10.1002&#x2F;mp.70078</dcvalue>
<dcvalue element="description" qualifier="journalClass">1</dcvalue>
<dcvalue element="identifier" qualifier="bibliographicCitation">Medical&#x20;Physics,&#x20;v.52,&#x20;no.11</dcvalue>
<dcvalue element="citation" qualifier="title">Medical&#x20;Physics</dcvalue>
<dcvalue element="citation" qualifier="volume">52</dcvalue>
<dcvalue element="citation" qualifier="number">11</dcvalue>
<dcvalue element="description" qualifier="isOpenAccess">N</dcvalue>
<dcvalue element="description" qualifier="journalRegisteredClass">scie</dcvalue>
<dcvalue element="description" qualifier="journalRegisteredClass">scopus</dcvalue>
<dcvalue element="identifier" qualifier="wosid">001602047400001</dcvalue>
<dcvalue element="identifier" qualifier="scopusid">2-s2.0-105020246117</dcvalue>
<dcvalue element="relation" qualifier="journalWebOfScienceCategory">Radiology,&#x20;Nuclear&#x20;Medicine&#x20;&amp;&#x20;Medical&#x20;Imaging</dcvalue>
<dcvalue element="relation" qualifier="journalResearchArea">Radiology,&#x20;Nuclear&#x20;Medicine&#x20;&amp;&#x20;Medical&#x20;Imaging</dcvalue>
<dcvalue element="type" qualifier="docType">Article</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">RAY&#x20;COMPUTED-TOMOGRAPHY</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">U-NET</dcvalue>
<dcvalue element="subject" qualifier="keywordPlus">NETWORK</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">CT&#x20;Physics</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">metal&#x20;artifact&#x20;reduction</dcvalue>
<dcvalue element="subject" qualifier="keywordAuthor">unsupervised&#x20;learning</dcvalue>
</dublin_core>
