<?xml version="1.0" encoding="utf-8" standalone="no"?>
<dublin_core schema="dc">
<dcvalue element="contributor" qualifier="author">Hwang&#x20;Sangchul</dcvalue>
<dcvalue element="contributor" qualifier="author">Lee,&#x20;Deukhee</dcvalue>
<dcvalue element="date" qualifier="accessioned">2024-01-12T06:11:47Z</dcvalue>
<dcvalue element="date" qualifier="available">2024-01-12T06:11:47Z</dcvalue>
<dcvalue element="date" qualifier="created">2021-09-29</dcvalue>
<dcvalue element="date" qualifier="issued">2018-06</dcvalue>
<dcvalue element="identifier" qualifier="uri">https:&#x2F;&#x2F;pubs.kist.re.kr&#x2F;handle&#x2F;201004&#x2F;79416</dcvalue>
<dcvalue element="description" qualifier="abstract">Lumbar&#x20;disc&#x20;disease&#x20;is&#x20;a&#x20;common&#x20;affliction&#x20;in&#x20;today’s&#x20;society.&#x20;A&#x20;common&#x20;treatment&#x20;for&#x20;this&#x20;condition&#x20;is&#x20;minimally&#x20;invasive&#x20;endoscopic&#x20;surgery,&#x20;which&#x20;involves&#x20;the&#x20;guiding&#x20;of&#x20;a&#x20;needle&#x20;into&#x20;the&#x20;target&#x20;disc.&#x20;However,&#x20;an&#x20;epiduroscopy&#x20;can&#x20;accidentally&#x20;damage&#x20;surrounding&#x20;tissues&#x20;as&#x20;the&#x20;epidural&#x20;catheter&#x20;is&#x20;inserted&#x20;in&#x20;the&#x20;lower&#x20;back&#x20;and&#x20;guided&#x20;up&#x20;toward&#x20;the&#x20;affected&#x20;nerve&#x20;roots&#x20;based&#x20;only&#x20;on&#x20;preoperative&#x20;medical&#x20;images&#x20;and&#x20;anatomical&#x20;knowledge.&#x20;Thus,&#x20;we&#x20;propose&#x20;a&#x20;method&#x20;for&#x20;tracking&#x20;the&#x20;location&#x20;of&#x20;surgical&#x20;tools&#x20;based&#x20;on&#x20;radiographic&#x20;images.&#x20;In&#x20;detail,&#x20;our&#x20;method&#x20;involves&#x20;the&#x20;following:&#x20;photographing&#x20;a&#x20;surgical&#x20;tool&#x20;with&#x20;a&#x20;physical&#x20;marker&#x20;frame&#x20;composed&#x20;of&#x20;three&#x20;or&#x20;more&#x20;marker&#x20;bands;&#x20;an&#x20;information&#x20;processor,&#x20;which&#x20;detects&#x20;the&#x20;center&#x20;point&#x20;on&#x20;each&#x20;marker&#x20;band&#x20;in&#x20;the&#x20;photographed&#x20;image;&#x20;and&#x20;an&#x20;information&#x20;processor&#x20;that&#x20;estimates&#x20;a&#x20;three-dimensional&#x20;location&#x20;for&#x20;the&#x20;surgical&#x20;tool&#x20;based&#x20;on&#x20;the&#x20;distance&#x20;between&#x20;the&#x20;detected&#x20;center&#x20;point,&#x20;the&#x20;center&#x20;point&#x20;of&#x20;a&#x20;true&#x20;marker&#x20;band,&#x20;and&#x20;a&#x20;tracking&#x20;apparatus.</dcvalue>
<dcvalue element="language" qualifier="none">English</dcvalue>
<dcvalue element="publisher" qualifier="none">IEEE</dcvalue>
<dcvalue element="subject" qualifier="none">Computer&#x20;vision</dcvalue>
<dcvalue element="subject" qualifier="none">tool&#x20;tracking</dcvalue>
<dcvalue element="title" qualifier="none">3D&#x20;Pose&#x20;Estimation&#x20;of&#x20;Catheter&#x20;Band&#x20;Markers&#x20;based&#x20;on&#x20;Single-Plane&#x20;Fluoroscopy</dcvalue>
<dcvalue element="type" qualifier="none">Conference</dcvalue>
<dcvalue element="description" qualifier="journalClass">1</dcvalue>
<dcvalue element="identifier" qualifier="bibliographicCitation">15th&#x20;International&#x20;Conference&#x20;on&#x20;Ubiquitous&#x20;Robots&#x20;(UR),&#x20;pp.723&#x20;-&#x20;728</dcvalue>
<dcvalue element="citation" qualifier="title">15th&#x20;International&#x20;Conference&#x20;on&#x20;Ubiquitous&#x20;Robots&#x20;(UR)</dcvalue>
<dcvalue element="citation" qualifier="startPage">723</dcvalue>
<dcvalue element="citation" qualifier="endPage">728</dcvalue>
<dcvalue element="citation" qualifier="conferencePlace">US</dcvalue>
<dcvalue element="citation" qualifier="conferencePlace">하와이,&#x20;미국</dcvalue>
<dcvalue element="citation" qualifier="conferenceDate">2018-06-26</dcvalue>
<dcvalue element="relation" qualifier="isPartOf">2018&#x20;15TH&#x20;INTERNATIONAL&#x20;CONFERENCE&#x20;ON&#x20;UBIQUITOUS&#x20;ROBOTS&#x20;(UR)</dcvalue>
<dcvalue element="identifier" qualifier="wosid">000447274600098</dcvalue>
<dcvalue element="identifier" qualifier="scopusid">2-s2.0-85053497303</dcvalue>
</dublin_core>
