<?xml version="1.0" encoding="utf-8" standalone="no"?>
<dublin_core schema="dc">
<dcvalue element="contributor" qualifier="author">Lee,&#x20;Geon&#x20;Tae</dcvalue>
<dcvalue element="contributor" qualifier="author">Kang,&#x20;Byung&#x20;Ha</dcvalue>
<dcvalue element="contributor" qualifier="author">Yoo,&#x20;Hoseon</dcvalue>
<dcvalue element="date" qualifier="accessioned">2024-01-12T11:38:40Z</dcvalue>
<dcvalue element="date" qualifier="available">2024-01-12T11:38:40Z</dcvalue>
<dcvalue element="date" qualifier="created">2022-03-07</dcvalue>
<dcvalue element="date" qualifier="issued">1996-08</dcvalue>
<dcvalue element="identifier" qualifier="issn">0146-955X</dcvalue>
<dcvalue element="identifier" qualifier="uri">https:&#x2F;&#x2F;pubs.kist.re.kr&#x2F;handle&#x2F;201004&#x2F;85910</dcvalue>
<dcvalue element="description" qualifier="abstract">An&#x20;experimental&#x20;study&#x20;has&#x20;been&#x20;carried&#x20;out&#x20;to&#x20;investigate&#x20;the&#x20;effects&#x20;of&#x20;the&#x20;combination&#x20;of&#x20;the&#x20;different&#x20;wire&#x20;mesh&#x20;number&#x20;in&#x20;regenerator,&#x20;and&#x20;the&#x20;tube&#x20;number&#x20;in&#x20;cooler&#x20;on&#x20;the&#x20;cooling&#x20;performance&#x20;of&#x20;a&#x20;Vuilleumier&#x20;cycle&#x20;heat&#x20;pump.&#x20;A&#x20;wide&#x20;range&#x20;of&#x20;charging&#x20;pressures,&#x20;heater&#x20;tube&#x20;temperatures&#x20;and&#x20;revolution&#x20;speeds&#x20;are&#x20;also&#x20;considered.&#x20;The&#x20;results&#x20;indicate&#x20;that&#x20;the&#x20;cooling&#x20;performance&#x20;is&#x20;improved&#x20;with&#x20;the&#x20;proper&#x20;combination&#x20;of&#x20;different&#x20;wire&#x20;meshes&#x20;in&#x20;the&#x20;cold&#x20;regenerator.&#x20;More&#x20;tubes&#x20;in&#x20;a&#x20;cooler&#x20;are&#x20;desirable&#x20;for&#x20;better&#x20;cooling&#x20;performance.&#x20;It&#x20;is&#x20;also&#x20;found&#x20;that&#x20;the&#x20;cooling&#x20;capacity&#x20;is&#x20;enhanced,&#x20;whereas&#x20;COP&#x20;is&#x20;reduced,&#x20;with&#x20;an&#x20;increase&#x20;in&#x20;the&#x20;heater&#x20;tube&#x20;temperature&#x20;and&#x20;revolution&#x20;speed.&#x20;Both&#x20;the&#x20;cooling&#x20;capacity&#x20;and&#x20;COP&#x20;are&#x20;increased&#x20;with&#x20;a&#x20;higher&#x20;charging&#x20;pressure.</dcvalue>
<dcvalue element="language" qualifier="none">English</dcvalue>
<dcvalue element="publisher" qualifier="none">IEEE</dcvalue>
<dcvalue element="title" qualifier="none">Effects&#x20;of&#x20;geometric&#x20;configuration&#x20;on&#x20;the&#x20;cooling&#x20;performance&#x20;of&#x20;a&#x20;Vuilleumier&#x20;cycle&#x20;heat&#x20;pump</dcvalue>
<dcvalue element="type" qualifier="none">Conference</dcvalue>
<dcvalue element="description" qualifier="journalClass">1</dcvalue>
<dcvalue element="identifier" qualifier="bibliographicCitation">1996&#x20;31st&#x20;Intersociety&#x20;Energy&#x20;Conversion&#x20;Engineering&#x20;Conference,&#x20;pp.781&#x20;-&#x20;786</dcvalue>
<dcvalue element="citation" qualifier="title">1996&#x20;31st&#x20;Intersociety&#x20;Energy&#x20;Conversion&#x20;Engineering&#x20;Conference</dcvalue>
<dcvalue element="citation" qualifier="startPage">781</dcvalue>
<dcvalue element="citation" qualifier="endPage">786</dcvalue>
<dcvalue element="citation" qualifier="conferencePlace">US</dcvalue>
<dcvalue element="citation" qualifier="conferencePlace">Washington,&#x20;DC,&#x20;USA</dcvalue>
<dcvalue element="citation" qualifier="conferenceDate">1996-08-11</dcvalue>
<dcvalue element="relation" qualifier="isPartOf">Proceedings&#x20;of&#x20;the&#x20;Intersociety&#x20;Energy&#x20;Conversion&#x20;Engineering&#x20;Conference</dcvalue>
<dcvalue element="identifier" qualifier="scopusid">2-s2.0-0030386904</dcvalue>
</dublin_core>
