Viable AC Two-probe Impedance Spectroscopy based on Spatially-limited Contact Probe for SOFC Cathode

Authors
Lee, J. -H.Ji, H. -I.Kim, H. -R.Son, J. -W.Hwang, J. -H.
Issue Date
2011
Publisher
ELECTROCHEMICAL SOC INC
Citation
12th International Symposium on Solid Oxide Fuel Cells (SOFC), v.35, no.1, pp.1995 - 1999
Abstract
We repor on a unique characterization method for the electrode reactions of SOFCs via impedance spectroscopy combined with a spatially-constricted contact based on a robust electrolyte which is expected to give more reliable measurement set-up. Various electrode materials were chosen to validate our method and the corresponding impedance phenomena were analyzed to give an insight for optimization of the SOFC electrode. The ramifications of "limited-contact" impedance spectroscopy are discussed for an exhaustive understanding of electrode-related polarizations in SOFCs.
ISSN
1938-5862
URI
https://pubs.kist.re.kr/handle/201004/115729
DOI
10.1149/1.3570189
Appears in Collections:
KIST Conference Paper > 2011
Files in This Item:
There are no files associated with this item.