High-performance nanogap electrode-based impedimetric sensor for direct DNA assays

Authors
Lee, HyunjungKeem, Joo OakCho, HyunminChoi, Jong MinChung, Won SeokJeon, Dae-YoungLee, Dong SuShin, Yong-Beom
Issue Date
2018-10-30
Publisher
ELSEVIER ADVANCED TECHNOLOGY
Citation
BIOSENSORS & BIOELECTRONICS, v.118, pp.153 - 159
Abstract
The rapid and sensitive detection of pathogen DNA (Deoxyribonucleic acid) would be essential for diagnosis and appropriate antibiotic treatment time. Herein, we report a novel direct DNA detectable impedimetric sensor. Direct assay of the amplified target DNA (mecA gene from methicillin-resistant Staphylococcus aureus (MRSA)) was performed using the PCR (polymerase chain reaction) product without any purification. Even though there are lots of PCR reagents and excess salts in sample PCR product, the nanogap electrode-based impedimetric sensor was able to detect DNA amplification fast in 5th PCR cycle which had 260 fM mecA gene in sample originally. The 70 nm gap electrode sensor yielded over 20% signal increase at the 5th PCR cycle and the impedance change grew up to about 60% at 25th in case of sample with 260 fM mecA gene template originally. The increased concentration of target DNA template led to the rise in impedance change such as 60% up at 5th and 120% up at 25th cycle with 260 pM, respectively. It is very outstanding result as compared with the traditional PCR agarose gel. Besides, it is 7-fold superior sensitivity to the microgap electrode. Furthermore, genomic DNA sample extracted from MRSA was detected rapidly. The nanogap electrode-based impedimetric sensor could be a good candidate for a rapid, sensitive, and low-cost electrical biosensor for DNA characterization in diagnostics and disease monitoring.
Keywords
ESCHERICHIA-COLI O157-H7; RESISTANT STAPHYLOCOCCUS-AUREUS; RAPID DETECTION; IMMUNOMAGNETIC SEPARATION; PATHOGENIC BACTERIA; FLOW-CYTOMETRY; REAL-TIME; PCR; BIOSENSORS; IDENTIFICATION; ESCHERICHIA-COLI O157-H7; RESISTANT STAPHYLOCOCCUS-AUREUS; RAPID DETECTION; IMMUNOMAGNETIC SEPARATION; PATHOGENIC BACTERIA; FLOW-CYTOMETRY; REAL-TIME; PCR; BIOSENSORS; IDENTIFICATION; Nanogap; Impedimetric sensor; Direct DNA assay; MecA gene; Theoretical calculation; Label-free
ISSN
0956-5663
URI
https://pubs.kist.re.kr/handle/201004/120764
DOI
10.1016/j.bios.2018.07.050
Appears in Collections:
KIST Article > 2018
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.