Fabrication of nanoporous gold thin films on glass substrates for amperometric sensing of aniline
- Authors
 - Lee, Keon-U; Trung Hieu Tran; Kim, Sang Hoon; Shin, Hyung-Joon
 
- Issue Date
 - 2017-08-05
 
- Publisher
 - ELSEVIER SCIENCE SA
 
- Citation
 - JOURNAL OF ALLOYS AND COMPOUNDS, v.713, pp.132 - 137
 
- Abstract
 - Nanoporous gold (NP-Au) thin films were fabricated on glass substrates by dealloying an Au-Si alloy produced by co-deposition of Au and Si. Si was selectively removed from the Au-Si alloy with potassium hydroxide solution, which is a very simple and safe dealloying method. We investigated the optimum conditions for sputtering and dealloying to obtain stable and durable nanoporous films. The NP-Au films were used as a working electrode for amperometric sensing of aniline in water and exhibited a wider sensing range and lower detection limit than NP-Au electrodes fabricated on Si substrates with HF etchant. The larger surface roughness factor of the NP-Au sensor is responsible for the enhanced sensing performance. (C) 2017 Elsevier B.V. All rights reserved.
 
- Keywords
 - DOPED DIAMOND ELECTRODES; ELECTROCHEMICAL OXIDATION; CYCLIC VOLTAMMETRY; GAS; TEMPERATURE; ACTUATION; LIQUID; DOPED DIAMOND ELECTRODES; ELECTROCHEMICAL OXIDATION; CYCLIC VOLTAMMETRY; GAS; TEMPERATURE; ACTUATION; LIQUID; Nanoporous gold; Heat-treatment; Sensor; Thin films
 
- ISSN
 - 0925-8388
 
- URI
 - https://pubs.kist.re.kr/handle/201004/122425
 
- DOI
 - 10.1016/j.jallcom.2017.04.173
 