루버 집진기의 성능특성

Other Titles
Performance characteristics of louver dust collectors
Authors
우상희김종범박통일육세진권순박배귀남
Issue Date
2016-03
Publisher
한국입자에어로졸학회
Citation
Particle and aerosol research = 한국입자에어로졸학회지, v.12, no.1, pp.11 - 20
Abstract
A large amount of wear dust generated during train operation is a major dust source in urban railway tunnels. To check possibility of a louver dust collector for the removal of dust in the railway tunnel, five louver dust collector models were designed and their performance was tested in a wind tunnel. JIS Z 8901 Class 8 dust was used as a test dust. Pressure drop and particle collection efficiency were evaluated with the face velocity ranging from 1 m/s to 4 m/s. At this low velocity range, particle collection efficiency of the louver dust collector was found to be insensitive to air velocity and design parameters. Pressure drop was under 40 Pa, and PM10 and PM2.5 collection efficiencies were approximately 50% and 30%, respectively.
Keywords
dust collector; louver; particle collection efficiency; pressure drop; urban railway
ISSN
1738-8716
URI
https://pubs.kist.re.kr/handle/201004/124313
DOI
10.11629/jpaar.2016.12.1.011
Appears in Collections:
KIST Article > 2016
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.