Fast Myoglobin Detection Using Nanofluidic Electrokinetic Trapping Technique

Authors
Chun, DongWonKim, Sang HuiSong, HyungwanKwak, SeungminKim, YooChanSeok, HyunGwangLee, Sang-MyungLee, Jeong Hoon
Issue Date
2013-01
Publisher
JAPAN SOC APPLIED PHYSICS
Citation
APPLIED PHYSICS EXPRESS, v.6, no.1
Abstract
We report on the preconcentration-enhanced fast collection of myoglobin protein for the rapid detection of myocardial infarction. We use a one-dimensional micro/nanofluidic chip for electrokinetic preconcentration and demonstrate that the preconcentration factor of 1 ng/ml Alexa Fluor 488-labeled myoglobin is similar to 1000 within 200 s, where the protein had a weak negative charge, thereby making it hard to perform electrokinetic trapping for neutral-like proteins. The potential feasibility with new assay strategies for use in a rapid immunoassay screening test for myocardial infarction is discussed. (C) 2013 The Japan Society of Applied Physics
Keywords
PRECONCENTRATION; BIOMARKERS; MEMBRANE; PROTEINS; PRECONCENTRATION; BIOMARKERS; MEMBRANE; PROTEINS; Myoglobin detection; nanofluidics; Electrokinetic trapping
ISSN
1882-0778
URI
https://pubs.kist.re.kr/handle/201004/128481
DOI
10.7567/APEX.6.017001
Appears in Collections:
KIST Article > 2013
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.