Efficacy of an Injectable Thermosensitive Gel on Postoperative Adhesion in Rat Model
- Authors
- Ahn, Hye Seong; Lee, Hyuk-Joon; Yoo, Moon-Won; Jeong, Sang-Ho; Han, Tae-Su; Kim, Woo-Ho; Song, Soo-Chang; Yang, Han-Kwang
- Issue Date
- 2010-10
- Publisher
- KOREAN SURGICAL SOCIETY
- Citation
- JOURNAL OF THE KOREAN SURGICAL SOCIETY, v.79, no.4, pp.239 - 245
- Abstract
- Purpose: For easy application to targeted area or in laparoscopic surgery, proper injectable antiadhesive agents are needed. The efficacy of two injectable antiadhesive agents-the thermosensitive poly (organophosphazene) hydrogel (Gel group) and a mixed solution of hyaluronate and carboxymethyl cellulose (Guardix-sol (R), Hanmi Medicare, Korea; Gd group) were compared with that of a positive control (one established membranous agent [Interceed (R), Johnson & Johnson, USA; IC group]) and negative control (phosphate buffered saline, control group). Methods: Eight ischemic buttons were created on both sides of the peritoneum in twenty-four male Sprague Dawley rats. Each of the solutions, or membrane agent was applied before closing of the wound according to groups (six rats per group). Two rats in the IC group were excluded because of death or intraoperative bleeding. Animals were sacrificed at two or four weeks after surgery. The number of adhesion-forming ischemic buttons and the weight gain were analyzed. Results: The overall number of adhered ischemic buttons were 23 in the control group (n=48), 22 in the Gd group (n=48), 14 in the Gel group (n=48) and 0 in the IC group (n=32). Overall number of adhered ischemic buttons of the Gd group was not significantly different from that of the control group (P=1.000). However that of the Gel group was smaller than that of the control group, although not statistically significant (P=0.093). Conclusion: The Gel group demonstrated some possibility of having an antiadhesive effect, and the Gd group failed to show antiadhesive effect, in contrast to IC group. A large-scale preclinical study is required to verify these findings. (J Korean Surg Soc 2010;79:239-245)
- Keywords
- PERITONEAL ADHESIONS; ABDOMINAL ADHESIONS; SODIUM HYALURONATE; PREVENTION; SURGERY; MULTICENTER; MEMBRANE; Postoperative adhesion; Ischemic button model; Antiadhesive barrier; Thermosensitive polymer
- ISSN
- 2233-7903
- URI
- https://pubs.kist.re.kr/handle/201004/131020
- DOI
- 10.4174/jkss.2010.79.4.239
- Appears in Collections:
- KIST Article > 2010
- Files in This Item:
There are no files associated with this item.
- Export
- RIS (EndNote)
- XLS (Excel)
- XML
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.