Biomechanical testing of hybrid hamstring graft tibial fixation in anterior cruciate ligament reconstruction

Authors
Yoo, Jae ChulAhn, Jin HwanKim, Jae HoonKim, Byung KwanChoi, Kui WonBae, Tae SooLee, Chang Yang
Issue Date
2006-12
Publisher
ELSEVIER SCIENCE BV
Citation
KNEE, v.13, no.6, pp.455 - 459
Abstract
Hamstring tendon using quadrupled semitendinosus and gracilis autografts is a well-established technique for ACL reconstruction. However, several methods have been used for tibial fixation of the tendon graft. The purpose of this study was to compare the biornechanical characteristics of quadrupled hamstring graft tibial fixation using three different fixation methods. Nine matched pairs (18 specimens) of cadaver tibias were divided into three groups of six specimens. The first group was fixed with only a tapered 30-mm bioabsorbable screw (BIS), the second group was fixed first with a BIS and then the remaining tendon portion was additionally fixed with a titanium cortical screw and spike washer, and the third group was fixed with only a cortical screw and spike washer. A custom-made probe hook was mounted on a load cell (Interface, MFG, Scottsdale, AZ) to measure the ACL tension before and after the final tibial fixation. Group 2 displayed greater mean maximum load at failure than both groups 1 and 3 (p < 0.05). The stiffness of the graft nearly doubled in group 2 compared to groups 1 and 3 (p < 0.05). All specimens failed by slippage and pullout. Biomechanical testing with cadavers showed that a BIS and additional cortical screw and spike washer fixation to the distal hamstring tendon resulted in higher load at failure and stiffness compared to either BIS or cortical screw and spike washer fixation alone. (c) 2006 Elsevier B.V. All rights reserved.
Keywords
BIOABSORBABLE INTERFERENCE SCREW; PATELLAR TENDON; FOLLOW-UP; BONE; AUTOGRAFTS; TENSION; KNEE; REPLACEMENT; PLACEMENT; STRENGTH; BIOABSORBABLE INTERFERENCE SCREW; PATELLAR TENDON; FOLLOW-UP; BONE; AUTOGRAFTS; TENSION; KNEE; REPLACEMENT; PLACEMENT; STRENGTH; anterior cruciate ligament reconstruction; bioabsorbable interference screw; hamstring tendon; tibial fixation; biomechanical testing
ISSN
0968-0160
URI
https://pubs.kist.re.kr/handle/201004/134918
DOI
10.1016/j.knee.2006.08.001
Appears in Collections:
KIST Article > 2006
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.