Flow imaging of dilute colloidal suspension in PDMS-based microfluidic chip using fluorescence microscopy

Authors
Chun, MSLee, S
Issue Date
2005-10-05
Publisher
ELSEVIER
Citation
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, v.267, no.1-3, pp.86 - 94
Abstract
A slit-like flow channel was designed to allow for fluorescent microscope visualization in the microfluidic chip fabricated with glass substrate and polydimethylsiloxane (PDMS). For the exposure time, moving fluorescent polystyrene latexes of 1 mu m radius result in image streaks, where the latex concentration is sufficiently dilute underlying the condition of simple fluid. Applying the data processing method for particle streak imaging developed ourselves, the linear velocity of particle at the lateral position of the channel was determined in terms of a ratio of the real distance to the number of pixels. It is obvious that the velocity profile of suspension depends on the surface properties of the microchannel wall. The reliability of the velocity profile determined by the flow imaging is justified by comparing with the measured volumetric flow rate. We recognized the behavior of fluid slip in velocity profiles at the hydrophobic surface of PDMS wall. The slip length inferred from the experimental results was evaluated ranging 6-8 mu m. (c) 2005 Elsevier B.V. All rights reserved.
Keywords
PRESSURE; PARTICLES; MIGRATION; SLIP; PRESSURE; PARTICLES; MIGRATION; SLIP; particle streak; microfluidic chip; colloidal suspension; slip velocity; fluorescent microscope; surface potential
ISSN
0927-7757
URI
https://pubs.kist.re.kr/handle/201004/136056
DOI
10.1016/j.colsurfa.2005.06.046
Appears in Collections:
KIST Article > 2005
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE