dc.description.abstract | A low pressure impactor is an impaction device to separate airborne particles into aerodynamic size classes at low pressure condition. We designed a two-stage low-pressure impactor to classify submicron sized environmental aerosols. Performance evaluation was carried out for stages 1 and 2 by using an electrical method. Monodisperse liquid dioctyl sebacate (DOS) particles were generated using evaporation-condensation process followed by electrostatic classification using a DMA (differential mobility analyzer). The test particles were in the range of 0.08~0.8 m. For the evaluation of the impactor we used two electrometers; one was connected to the impaction plate of the impactor and the other was to the Faraday cage used as a backup filter. The effect of polydispersity of test aerosols on the performance was investigated. The results showed that the experimental 50-% cutoff diameters at each impactor's operation pressure were 0.53 and 0.187 m for stages 1 and stage 2, respectively. The effects of operation pressure on the cutoff diameter and the steepness of collection efficiency curves were also investigated. | - |
dc.publisher | 대한기계학회 | - |
dc.title | 서브마이크론 입자 측정용 저압 임팩터의 설계 및 성능평가 | - |
dc.title.alternative | Design and Performance Evaluation of a Low Pressure Impactor for Sampling Submicron Aerosols | - |
dc.type | Article | - |
dc.description.journalClass | 2 | - |
dc.identifier.bibliographicCitation | 대한기계학회논문집 B, v.28, no.3, pp.349 - 358 | - |
dc.citation.title | 대한기계학회논문집 B | - |
dc.citation.volume | 28 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 349 | - |
dc.citation.endPage | 358 | - |
dc.description.journalRegisteredClass | kci | - |
dc.identifier.kciid | ART001094877 | - |
dc.subject.keywordAuthor | Low Pressure Impactor(저압 임팩터) | - |
dc.subject.keywordAuthor | Submicron Particle(서브마이크론 입자) | - |
dc.subject.keywordAuthor | Cascade Impactor(다단 임팩터) | - |
dc.subject.keywordAuthor | Cutoff Diameter(분리입경) | - |
dc.subject.keywordAuthor | Low Pressure Impactor(저압 임팩터) | - |
dc.subject.keywordAuthor | Submicron Particle(서브마이크론 입자) | - |
dc.subject.keywordAuthor | Cascade Impactor(다단 임팩터) | - |
dc.subject.keywordAuthor | Cutoff Diameter(분리입경) | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.