힘 피드백 기반의 세포조작을 위한 세포막 침습력 측정

Other Titles
Cellular Force Sensing for Force Feedback-Based Biological Cell Injection
Authors
김덕호김병규윤석준강현재
Issue Date
2003-12
Publisher
대한기계학회
Citation
대한기계학회논문집 A, v.27, no.12, pp.2079 - 2084
Abstract
In biological cell manipulation, manual thrust or penetration of an injection pipette into an embryo cell is currently performed by a skilled operator, relying on visual feedback information only. Accurately measuring cellular forces is a requirement for minimally invasive cell injections. Moreover, the cellular force sensing is essential in investigating the biophysical properties for cell injury and membrane modeling studies. This paper presents cellular force measurements for the force feedback-based biomanipulation. Cellular force measurement system using piezoelectric polymer sensor is implemented to measure the penetration force of a zebra fish egg cell. First, measurement system setup and calibration are described. Second, the force feedback-based biomanipulation is experimentally carried out. Experimental results show that it successfully supplies real-time cellular force feedback to the operator at tens of uN and thus plays a main role in improving the reliability of biological cell injection tasks.
ISSN
1226-4873
URI
https://pubs.kist.re.kr/handle/201004/138047
Appears in Collections:
KIST Article > 2003