Focused ultrasound enhances the anesthetic effects of topical lidocaine in rats

Title
Focused ultrasound enhances the anesthetic effects of topical lidocaine in rats
Authors
윤경호김현철이원혜Mark Bollke유승식
Issue Date
2021-05
Publisher
BMC ANESTHESIOLOGY
Citation
VOL 21, 158
Abstract
Background: High-intensity ultrasound has been used to induce acoustic cavitation in the skin and subsequently enhances skin permeability to deliver hydrophobic topical medications including lidocaine. In contrast, instead of changing skin permeability, pulsed application of low-intensity focused ultrasound (FUS) has shown to noninvasively and temporarily disrupt drug-plasma protein binding, thus has potential to enhance the anesthetic effects of hydrophilic lidocaine hydrochloride through unbinding it from serum/interstitial α1-acid glycoprotein (AAG). Methods: FUS, operating at fundamental frequency of 500 kHz, was applied pulse-mode (55-ms pulse duration, 4-Hz pulse repetition frequency) at a spatial-peak pulse-average intensity of 5 W/cm2. In vitro equilibrium dialysis was performed to measure the unbound concentration of lidocaine (lidocaine hydrochloride) from dialysis cassettes, one located at the sonication focus and the other outside the sonication path, all immersed in phosphate-buffered saline solution containing both lidocaine (10 ?g/mL) and human AAG (5 mg/mL). In subsequent animal experiments (Sprague-Dawley rats, n = 10), somatosensory evoked potential (SSEP), elicited by electrical stimulations to the unilateral hind leg, was measured under three experimental conditions―applications of FUS to the unilateral thigh area at the site of administered topical lidocaine, FUS only, and lidocaine only. Skin temperature was measured before and after sonication. Passive cavitation detection was also performed during sonication to evaluate the presence of FUS-induced cavitation. Results: Sonication increased the unbound lidocaine concentration (8.7 ± 3.3 %) from the dialysis cassette, compared to that measured outside the sonication path (P < 0.001). Application of FUS alone did not alter the SSEP while administration of lidocaine reduced its P23 component (i.e., a positive peak at 23 ms latency). The FUS co
URI
https://pubs.kist.re.kr/handle/201004/73154
ISSN
1471-2253
Appears in Collections:
KIST Publication > Article
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE