Novel microfluidic chip generating mono-disperse core-shell microcapsules
- Authors
- Kim, C.; Kang, E.; Kim, Y.E.; Lee, K.J.; Kim, T.S.; Kang, J.Y.
- Issue Date
- 2009-06
- Publisher
- IEEE
- Citation
- TRANSDUCERS 2009 - 15th International Conference on Solid-State Sensors, Actuators and Microsystems, pp.2022 - 2025
- Abstract
- In this paper, we propose a microfluidic chip to generate well-defined microcapsule. In order to make core-shell microcapsule, a simple design capable of 3-dimensional hydrodynamic focusing was embedded in the proposed microfluidic chip. Cell suspension is focused 3-dimensional hydrodynamic in microchannel by the hillock based geometries, and then the core-shell structure of alginate microcapsules with thin membrane can be clearly identified. The mouse embryonic carcinoma cell line, P19, was cultured in the capsules and spherical EB (more than 70 %) with strong compaction was successfully formed within 2 days. ?2009 IEEE.
- ISSN
- 0000-0000
- URI
- https://pubs.kist.re.kr/handle/201004/80953
- DOI
- 10.1109/SENSOR.2009.5285660
- Appears in Collections:
- KIST Conference Paper > 2009
- Files in This Item:
There are no files associated with this item.