Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Shin, Hyogeun | - |
dc.contributor.author | Yoon, Gun-Wook | - |
dc.contributor.author | Choi, Woongsun | - |
dc.contributor.author | Lee, Donghwan | - |
dc.contributor.author | Choi, Hoyun | - |
dc.contributor.author | Jo, Deok Su | - |
dc.contributor.author | Choi, Nakwon | - |
dc.contributor.author | Yoon, Jun-Bo | - |
dc.contributor.author | Cho, Il-Joo | - |
dc.date.accessioned | 2024-01-19T10:03:49Z | - |
dc.date.available | 2024-01-19T10:03:49Z | - |
dc.date.created | 2023-03-16 | - |
dc.date.issued | 2023-02 | - |
dc.identifier.issn | 2397-4621 | - |
dc.identifier.uri | https://pubs.kist.re.kr/handle/201004/114017 | - |
dc.description.abstract | Miniaturized fluorescence imaging systems are promising platforms that overcome the limited use of conventional microscopes in the biomedical field. However, there are physical limitations for multicolor fluorescence imaging in existing miniaturized imaging systems because multiple filters have to be integrated into a small structure. Here, we present a miniaturized multicolor fluorescence imaging system integrated with single polydimethylsiloxane (PDMS) light-guide plate (LGP) for multicolor fluorescence imaging. The PDMS LGP allows guiding the transmitted light from the light source only to the fluorescent samples regardless of the wavelength of the light source. Thus, our system is capable of multicolor fluorescence imaging without multiple filters that block the excitation light. We demonstrated the usability of our system in the biomedical field by observing green- and red-labeled cells in the incubator. Our proposed system can be used in a wide range of applications for studies that require multicolor fluorescence imaging in the biomedical field. | - |
dc.language | English | - |
dc.publisher | Nature Publishing Group | - |
dc.title | Miniaturized multicolor fluorescence imaging system integrated with a PDMS light-guide plate for biomedical investigation | - |
dc.type | Article | - |
dc.identifier.doi | 10.1038/s41528-023-00243-6 | - |
dc.description.journalClass | 1 | - |
dc.identifier.bibliographicCitation | npj Flexible Electronics, v.7, no.1 | - |
dc.citation.title | npj Flexible Electronics | - |
dc.citation.volume | 7 | - |
dc.citation.number | 1 | - |
dc.description.isOpenAccess | Y | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.identifier.wosid | 000931460500001 | - |
dc.identifier.scopusid | 2-s2.0-85147977403 | - |
dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
dc.relation.journalWebOfScienceCategory | Materials Science, Multidisciplinary | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Materials Science | - |
dc.type.docType | Article | - |
dc.subject.keywordPlus | WIDE | - |
dc.subject.keywordPlus | BIOMARKERS | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.