Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Changheon | - |
dc.contributor.author | Han, Bo Hoon | - |
dc.contributor.author | Kim, Dongwoo | - |
dc.contributor.author | Lee, Gyubok | - |
dc.contributor.author | Hong, Changgi | - |
dc.contributor.author | Kang, Ji Yoon | - |
dc.contributor.author | Lee, Kangwon | - |
dc.date.accessioned | 2024-01-19T12:31:06Z | - |
dc.date.available | 2024-01-19T12:31:06Z | - |
dc.date.created | 2022-04-03 | - |
dc.date.issued | 2022-03-15 | - |
dc.identifier.issn | 0925-4005 | - |
dc.identifier.uri | https://pubs.kist.re.kr/handle/201004/115508 | - |
dc.description.abstract | Exosomes are extracellular vesicles 15-150 nm in size and serve as delivery vehicles for long-distance intercellular communication. Exosomes contain various biomolecules derived from the cell cytosol and have potential applications in disease diagnosis and drug delivery. However, due to their low density, small size, and scarcity, reliable methods for the selective capture or efficient isolation of exosomes are required to broaden their range of applications. Particularly, the conventional method for selective exosome capture is based on a ligand-receptor interaction using a receptor that targets tetraspanin on the exosome surface. Sensing platforms detect the signal generated by the binding ligand in the sensing region; therefore, efficient exosome capture in a receptor-based exosome sensor platform has a significant impact on the detection performance. The conducting polymer polydiacetylene (PDA) has unique optical properties resulting from the polymerization of self-assembled diacetylene molecules, and PDA based platform can be used to indicate the degree of ligand-receptor interaction. When the PDA backbone is disturbed by an external stimulus, it produces a blue to red colorimetric transition and fluoresces in the red region without a label. Herein, it was confirmed that exosomes were more efficiently captured by a multi-target platform compared to a single-target platform. The PDA array platform demonstrated significantly improved exosome binding efficiency with a 4-8-fold increase in sensitivity compared to the single-target system. Moreover, the binding efficiency was high in low exosome concentration environments. Therefore, the multi-target exosome platform increases detection sensitivity through efficient exosome capture and this strategy can be universally applied to applications that use exosome-targeting receptors. | - |
dc.language | English | - |
dc.publisher | ELSEVIER SCIENCE SA | - |
dc.subject | TEMPERATURE | - |
dc.subject | BIOGENESIS | - |
dc.subject | VESICLES | - |
dc.subject | DELIVERY | - |
dc.subject | SENSOR | - |
dc.title | Multi-target polydiacetylene liposome-based biosensor for improved exosome detection | - |
dc.type | Article | - |
dc.identifier.doi | 10.1016/j.snb.2021.131286 | - |
dc.description.journalClass | 1 | - |
dc.identifier.bibliographicCitation | SENSORS AND ACTUATORS B-CHEMICAL, v.355 | - |
dc.citation.title | SENSORS AND ACTUATORS B-CHEMICAL | - |
dc.citation.volume | 355 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.identifier.wosid | 000744566600006 | - |
dc.identifier.scopusid | 2-s2.0-85121741616 | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
dc.relation.journalWebOfScienceCategory | Electrochemistry | - |
dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
dc.relation.journalResearchArea | Chemistry | - |
dc.relation.journalResearchArea | Electrochemistry | - |
dc.relation.journalResearchArea | Instruments & Instrumentation | - |
dc.type.docType | Article | - |
dc.subject.keywordPlus | TEMPERATURE | - |
dc.subject.keywordPlus | BIOGENESIS | - |
dc.subject.keywordPlus | VESICLES | - |
dc.subject.keywordPlus | DELIVERY | - |
dc.subject.keywordPlus | SENSOR | - |
dc.subject.keywordAuthor | Polydiacetylene | - |
dc.subject.keywordAuthor | Exosome | - |
dc.subject.keywordAuthor | Multi-receptors | - |
dc.subject.keywordAuthor | Biosensor | - |
dc.subject.keywordAuthor | Sensitivity | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.