Full metadata record

DC Field Value Language
dc.contributor.authorJeon, Jiyun-
dc.contributor.authorPark, Chan Sam-
dc.contributor.authorLee, Sangheon-
dc.contributor.authorChae, Hee Young-
dc.contributor.authorKim, Jae Joon-
dc.contributor.authorSon, Hungsun-
dc.date.accessioned2024-01-19T12:33:56Z-
dc.date.available2024-01-19T12:33:56Z-
dc.date.created2022-04-03-
dc.date.issued2022-02-
dc.identifier.issn0018-9456-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/115671-
dc.description.abstractThis article aims to develop a miniaturized magnetic induction tomography (MIT) system with a multi-channel phase-domain transceiver integrated circuit (IC). MIT is an imaging technique using phase shift between a primary magnetic field and induced field caused by the conductivity of a target object. Due to the weak strength of time-varying magnetic field, it is difficult to differentiate the magnetic field interaction. In particular, if the conductivity of the target object is low, the induced field is too small to identify the phase difference. The magnetic dipole model is applied to modeling the MIT system and analyzing performance. The model offers an effective means to analyze and visualize magnetic field interaction in multi-channel by the sum of magnetic dipoles. Then, a multi-channel MIT detection device is developed to include the phase-domain transceiver for automatic high-resolution phase measurement and wireless connectivity, achieving enhanced power efficiency and miniaturization. Finally, the multi-channel MIT system is applied to identify the various sizes of cracks on carbon fiber rods. The sensitivity of the system is analyzed by imaging the cracks by multi-channel measurement. The results show that the multi-channel MIT system can be successfully miniaturized and perform the nondestructive test (NDT).-
dc.languageEnglish-
dc.publisherInstitute of Electrical and Electronics Engineers-
dc.titleMagnetic Induction Tomography Using Multi-Channel Phase-Domain Transceiver for Structural Health Monitoring-
dc.typeArticle-
dc.identifier.doi10.1109/TIM.2022.3151951-
dc.description.journalClass1-
dc.identifier.bibliographicCitationIEEE Transactions on Instrumentation and Measurement, v.71-
dc.citation.titleIEEE Transactions on Instrumentation and Measurement-
dc.citation.volume71-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.identifier.wosid000766618900016-
dc.identifier.scopusid2-s2.0-85124829081-
dc.relation.journalWebOfScienceCategoryEngineering, Electrical & Electronic-
dc.relation.journalWebOfScienceCategoryInstruments & Instrumentation-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaInstruments & Instrumentation-
dc.type.docTypeArticle-
dc.subject.keywordPlusSYSTEM-
dc.subject.keywordAuthorMagnetic fields-
dc.subject.keywordAuthorConductivity-
dc.subject.keywordAuthorTransceivers-
dc.subject.keywordAuthorComputational modeling-
dc.subject.keywordAuthorMagnetic resonance imaging-
dc.subject.keywordAuthorCarbon-
dc.subject.keywordAuthorTomography-
dc.subject.keywordAuthorMagnetic dipole-
dc.subject.keywordAuthormagnetic induction tomography (MIT)-
dc.subject.keywordAuthormulti-channel measurement-
dc.subject.keywordAuthorphase-domain transceiver-
dc.subject.keywordAuthorsurface crack detection-
Appears in Collections:
KIST Article > 2022
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE