Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Ko, Seung Hyeon | - |
dc.contributor.author | Kim, Seung Wook | - |
dc.contributor.author | Lee, Yi Jae | - |
dc.date.accessioned | 2024-01-19T13:33:41Z | - |
dc.date.available | 2024-01-19T13:33:41Z | - |
dc.date.created | 2022-01-10 | - |
dc.date.issued | 2021-10 | - |
dc.identifier.issn | 2045-2322 | - |
dc.identifier.uri | https://pubs.kist.re.kr/handle/201004/116318 | - |
dc.description.abstract | We demonstrate a novel, flexible sensor with graphene oxide/PEDOT:PSS (GO/PEDOT:PSS) composite for voltammetric determination of selective low levels of dopamine. The well-distributed GO and EDOT:PSS suspension in water were deposited simply and polymerized. Consequently, the EDOT:PSS provided a strong interaction between GO and PEDOT:PSS, and it also had well-tailored interfacial properties that allowed the highly selective and sensitive determination of DA. Since the interfacial net charge is well-constructed, the sensor satisfies both the requirements of selectivity and the highly sensitive detection of low amounts of DA. In the results, the sensor with the GO/PEDOT:PSS composite exhibited a low interfacial impedance of about 281.46 +/- 30.95 omega at 100 Hz and a high charge storage capacity (53.94 +/- 1.08 mu C/cm(2)) for the detection of dopamine. In addition, the interference from ascorbic acid was reduced effectively to a minimum by electrostatic charge repelling of the AA and the distinct difference for the oxidation peak of the UA. Due to the fact that the GO/PEDOT:PSS composite had a net negative charge and, enhanced interfacial properties, the sensor showed a dopamine detection limit of 0.008 mu M and a sensitivity of 69.3 mu A/mu Mcm(2). | - |
dc.language | English | - |
dc.publisher | Nature Publishing Group | - |
dc.title | Flexible sensor with electrophoretic polymerized graphene oxide/PEDOT:PSS composite for voltammetric determination of dopamine concentration | - |
dc.type | Article | - |
dc.identifier.doi | 10.1038/s41598-021-00712-w | - |
dc.description.journalClass | 1 | - |
dc.identifier.bibliographicCitation | Scientific Reports, v.11, no.1 | - |
dc.citation.title | Scientific Reports | - |
dc.citation.volume | 11 | - |
dc.citation.number | 1 | - |
dc.description.isOpenAccess | Y | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.identifier.wosid | 000711622600089 | - |
dc.identifier.scopusid | 2-s2.0-85118250073 | - |
dc.relation.journalWebOfScienceCategory | Multidisciplinary Sciences | - |
dc.relation.journalResearchArea | Science & Technology - Other Topics | - |
dc.type.docType | Article | - |
dc.subject.keywordPlus | SULFUR-DOPED GRAPHENE | - |
dc.subject.keywordPlus | CARBON ELECTRODE | - |
dc.subject.keywordPlus | ASCORBIC-ACID | - |
dc.subject.keywordPlus | ELECTROCHEMICAL BIOSENSORS | - |
dc.subject.keywordPlus | URIC-ACID | - |
dc.subject.keywordPlus | OXIDE | - |
dc.subject.keywordPlus | DEPOSITION | - |
dc.subject.keywordPlus | OXYGEN | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.