Full metadata record

DC Field Value Language
dc.contributor.authorPark, Sangin-
dc.contributor.authorMun, Sungchul-
dc.contributor.authorHa, Jihyeon-
dc.contributor.authorKim, Laehyun-
dc.date.accessioned2024-01-19T14:04:20Z-
dc.date.available2024-01-19T14:04:20Z-
dc.date.created2022-01-10-
dc.date.issued2021-07-
dc.identifier.issn1424-8220-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/116717-
dc.description.abstractBoth physiological and neurological mechanisms are reflected in pupillary rhythms via neural pathways between the brain and pupil nerves. This study aims to interpret the phenomenon of motion sickness such as fatigue, anxiety, nausea and disorientation using these mechanisms and to develop an advanced non-contact measurement method from an infrared webcam. Twenty-four volunteers (12 females) experienced virtual reality content through both two-dimensional and head-mounted device interpretations. An irregular pattern of the pupillary rhythms, demonstrated by an increasing mean and standard deviation of pupil diameter and decreasing pupillary rhythm coherence ratio, was revealed after the participants experienced motion sickness. The motion sickness was induced while watching the head-mounted device as compared to the two-dimensional virtual reality, with the motion sickness strongly related to the visual information processing load. In addition, the proposed method was verified using a new experimental dataset for 23 participants (11 females), with a classification performance of 89.6% (n = 48) and 80.4% (n = 46) for training and test sets using a support vector machine with a radial basis function kernel, respectively. The proposed method was proven to be capable of quantitatively measuring and monitoring motion sickness in real-time in a simple, economical and contactless manner using an infrared camera.-
dc.languageEnglish-
dc.publisherMDPI-
dc.subjectHEART-RATE-VARIABILITY-
dc.subjectVIRTUAL-REALITY-
dc.subjectCOGNITIVE FATIGUE-
dc.subjectAUTONOMIC RESPONSES-
dc.subjectAUGMENTED REALITY-
dc.subjectNEURONAL-ACTIVITY-
dc.subjectVISUAL FATIGUE-
dc.subjectDISPLAYS-
dc.subjectSYSTEM-
dc.subjectCYBERSICKNESS-
dc.titleNon-Contact Measurement of Motion Sickness Using Pupillary Rhythms from an Infrared Camera-
dc.typeArticle-
dc.identifier.doi10.3390/s21144642-
dc.description.journalClass1-
dc.identifier.bibliographicCitationSENSORS, v.21, no.14-
dc.citation.titleSENSORS-
dc.citation.volume21-
dc.citation.number14-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.identifier.wosid000677057100001-
dc.identifier.scopusid2-s2.0-85109011041-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.relation.journalWebOfScienceCategoryEngineering, Electrical & Electronic-
dc.relation.journalWebOfScienceCategoryInstruments & Instrumentation-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaInstruments & Instrumentation-
dc.type.docTypeArticle-
dc.subject.keywordPlusHEART-RATE-VARIABILITY-
dc.subject.keywordPlusVIRTUAL-REALITY-
dc.subject.keywordPlusCOGNITIVE FATIGUE-
dc.subject.keywordPlusAUTONOMIC RESPONSES-
dc.subject.keywordPlusAUGMENTED REALITY-
dc.subject.keywordPlusNEURONAL-ACTIVITY-
dc.subject.keywordPlusVISUAL FATIGUE-
dc.subject.keywordPlusDISPLAYS-
dc.subject.keywordPlusSYSTEM-
dc.subject.keywordPlusCYBERSICKNESS-
dc.subject.keywordAuthormotion sickness-
dc.subject.keywordAuthorpupillary rhythms-
dc.subject.keywordAuthorcognitive load-
dc.subject.keywordAuthornon-contact measurement-
Appears in Collections:
KIST Article > 2021
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE