Full metadata record

DC Field Value Language
dc.contributor.authorBong, Ji-Hong-
dc.contributor.authorKim, Hong-Rae-
dc.contributor.authorJung, Jaeyong-
dc.contributor.authorPark, Jun-Hee-
dc.contributor.authorSung, Jeong Soo-
dc.contributor.authorLee, Chang Kyu-
dc.contributor.authorChoi, Kyung-Hak-
dc.contributor.authorShin, Seong-Shick-
dc.contributor.authorKang, Min-Jung-
dc.contributor.authorKim, Hyun Ok-
dc.contributor.authorLee, Do Young-
dc.contributor.authorPyun, Jae-Chul-
dc.date.accessioned2024-01-19T15:01:28Z-
dc.date.available2024-01-19T15:01:28Z-
dc.date.created2021-09-05-
dc.date.issued2021-04-15-
dc.identifier.issn0956-5663-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/117126-
dc.description.abstractHerein, we present switching-peptides for a one-step immunoassay, without the need for additional antibody treatment or washing steps to detect antigen-antibody interactions. Fluorescently labeled switching-peptides were dissociated from the immobilized antibody soon after the antigens were bound to the binding pockets. In this study, four different parts of the antibody (IgG) frame regions were chemically synthesized, and these peptides were bound to immobilized antibodies as switching-peptides. We presented the design principle of switching-peptides and used Pymol software, based on the changes in thermodynamic parameters, to study the interaction between antibodies and switching-peptides. The binding properties of switching-peptides were analyzed based on Forster resonance energy transfer between switching-peptides as well as between switching-peptides and antibodies (IgGs) isolated from different animals. The binding constants of the four switching-peptides to antibodies were estimated to be in the range of 1.48-3.29 mu M. Finally, the feasibility of using switching-peptides for the quantitative one-step immunoassay was demonstrated by human hepatitis B surface antigen (hHBsAg) detection and statistical comparison of the assay results with those of conventional ELISA. The limit of detection for HBsAg was determined to be 56 ng/mL, and the dynamic range was estimated to be 136 ng/mL-33 mu g/mL. These results demonstrate the feasibility of the one-step immunoassay for HBsAg.-
dc.languageEnglish-
dc.publisherELSEVIER ADVANCED TECHNOLOGY-
dc.titleSwitching-peptides for one-step immunoassay and its application to the diagnosis of human hepatitis B-
dc.typeArticle-
dc.identifier.doi10.1016/j.bios.2021.112996-
dc.description.journalClass1-
dc.identifier.bibliographicCitationBIOSENSORS & BIOELECTRONICS, v.178-
dc.citation.titleBIOSENSORS & BIOELECTRONICS-
dc.citation.volume178-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.identifier.wosid000621206100005-
dc.identifier.scopusid2-s2.0-85099960149-
dc.relation.journalWebOfScienceCategoryBiophysics-
dc.relation.journalWebOfScienceCategoryBiotechnology & Applied Microbiology-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.relation.journalWebOfScienceCategoryElectrochemistry-
dc.relation.journalWebOfScienceCategoryNanoscience & Nanotechnology-
dc.relation.journalResearchAreaBiophysics-
dc.relation.journalResearchAreaBiotechnology & Applied Microbiology-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalResearchAreaElectrochemistry-
dc.relation.journalResearchAreaScience & Technology - Other Topics-
dc.type.docTypeArticle-
dc.subject.keywordAuthorSwitching-peptide-
dc.subject.keywordAuthorOne-step immunoassay-
dc.subject.keywordAuthorFrame region-
dc.subject.keywordAuthorHepatitis-
dc.subject.keywordAuthorMedical diagnosis-
Appears in Collections:
KIST Article > 2021
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE