Full metadata record

DC Field Value Language
dc.contributor.author최준명-
dc.contributor.author안세혁-
dc.contributor.author김천우-
dc.contributor.author박정훈-
dc.contributor.author송호영-
dc.contributor.author조규진-
dc.date.accessioned2024-01-19T16:04:14Z-
dc.date.available2024-01-19T16:04:14Z-
dc.date.created2022-01-10-
dc.date.issued2020-11-
dc.identifier.issn2576-3202-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/117878-
dc.description.abstractStent placement in the gastrointestinal tract has emerged as an effective method of therapy for intestinal obstruction. In fluoroscopic guided stenting, clinicians first insert a hyper-elastic guidewire, and a stent introducer loaded with a compressed stent is passed along the guidewire to the desired deployment site. However, the high bending stiffness of the loaded stent introducer tends to straighten the inserted guidewire at the tortuous region. To overcome this issue, tubes of various stiffnesses are repeatedly inserted and removed. To optimize the mechanical properties of the devices for successful GI stenting, the interaction between the device and the environment should be considered as a key factor. In this study, conformability factor, a new index that abstracts the physical interaction for GI stenting was proposed. Based on the conformability factor, we proposed design requirements for variable stiffness continuum robots for GI stenting. The in vitro stent deployment experiment result shows that the proposed instrument can successfully deploy the loaded stent introducer without exchanging multiple tubes.-
dc.languageEnglish-
dc.publisherInstitute of Electrical and Electronics Engineers Inc.-
dc.titleDesign of Continuum Robot with Variable Stiffness for Gastrointestinal Stenting Using Conformability Factor-
dc.typeArticle-
dc.identifier.doi10.1109/TMRB.2020.3031842-
dc.description.journalClass1-
dc.identifier.bibliographicCitationIEEE Transactions on Medical Robotics and Bionics, v.2, no.4, pp.529 - 532-
dc.citation.titleIEEE Transactions on Medical Robotics and Bionics-
dc.citation.volume2-
dc.citation.number4-
dc.citation.startPage529-
dc.citation.endPage532-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscopus-
dc.identifier.scopusid2-s2.0-85115825618-
dc.subject.keywordAuthorBiomedical applications of radiation-
dc.subject.keywordAuthorcatheters-
dc.subject.keywordAuthorgastroenterology-
dc.subject.keywordAuthormanipulators-
dc.subject.keywordAuthormedical robotics-
Appears in Collections:
KIST Article > 2020
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE