Full metadata record

DC Field Value Language
dc.contributor.authorLee, Jungpyo-
dc.contributor.authorKo, Kyungmin-
dc.contributor.authorShin, Hyogeun-
dc.contributor.authorOh, Soo-Jin-
dc.contributor.authorLee, C. Justin-
dc.contributor.authorChou, Namsun-
dc.contributor.authorChoi, Nakwon-
dc.contributor.authorOh, Min Tack-
dc.contributor.authorLee, Byung Chul-
dc.contributor.authorJun, Seong Chan-
dc.contributor.authorCho, Il-Joo-
dc.date.accessioned2024-01-19T19:33:13Z-
dc.date.available2024-01-19T19:33:13Z-
dc.date.created2021-09-02-
dc.date.issued2019-07-15-
dc.identifier.issn2055-7434-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/119770-
dc.description.abstractNeuromodulation by ultrasound has recently received attention due to its noninvasive stimulation capability for treating brain diseases. Although there have been several studies related to ultrasonic neuromodulation, these studies have suffered from poor spatial resolution of the ultrasound and low repeatability with a fixed condition caused by conventional and commercialized ultrasound transducers. In addition, the underlying physics and mechanisms of ultrasonic neuromodulation are still unknown. To determine these mechanisms and accurately modulate neural circuits, researchers must have a precisely controllable ultrasound transducer to conduct experiments at the cellular level. Herein, we introduce a new MEMS ultrasound stimulation system for modulating neurons or brain slices with high spatial resolution. The piezoelectric micromachined ultrasonic transducers (pMUTs) with small membranes (submm membranes) generate enough power to stimulate neurons and enable precise modulation of neural circuits. We designed the ultrasound transducer as an array structure to enable localized modulation in the target region. In addition, we integrated a cell culture chamber with the system to make it compatible with conventional cell-based experiments, such as in vitro cell cultures and brain slices. In this work, we successfully demonstrated the functionality of the system by showing that the number of responding cells is proportional to the acoustic intensity of the applied ultrasound. We also demonstrated localized stimulation capability with high spatial resolution by conducting experiments in which cocultured cells responded only around a working transducer.-
dc.languageEnglish-
dc.publisherSPRINGERNATURE-
dc.subjectINTENSITY FOCUSED ULTRASOUND-
dc.subjectDEEP-BRAIN-STIMULATION-
dc.subjectTO-SUBSTRATUM ADHESION-
dc.subjectNEUROMODULATION-
dc.subjectVIBRATION-
dc.subjectCONTACT-
dc.subjectNUCLEUS-
dc.subjectNEURONS-
dc.titleA MEMS ultrasound stimulation system for modulation of neural circuits with high spatial resolution in vitro-
dc.typeArticle-
dc.identifier.doi10.1038/s41378-019-0070-5-
dc.description.journalClass1-
dc.identifier.bibliographicCitationMICROSYSTEMS & NANOENGINEERING, v.5-
dc.citation.titleMICROSYSTEMS & NANOENGINEERING-
dc.citation.volume5-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.identifier.wosid000477598400001-
dc.identifier.scopusid2-s2.0-85068996595-
dc.relation.journalWebOfScienceCategoryNanoscience & Nanotechnology-
dc.relation.journalWebOfScienceCategoryInstruments & Instrumentation-
dc.relation.journalResearchAreaScience & Technology - Other Topics-
dc.relation.journalResearchAreaInstruments & Instrumentation-
dc.type.docTypeArticle-
dc.subject.keywordPlusINTENSITY FOCUSED ULTRASOUND-
dc.subject.keywordPlusDEEP-BRAIN-STIMULATION-
dc.subject.keywordPlusTO-SUBSTRATUM ADHESION-
dc.subject.keywordPlusNEUROMODULATION-
dc.subject.keywordPlusVIBRATION-
dc.subject.keywordPlusCONTACT-
dc.subject.keywordPlusNUCLEUS-
dc.subject.keywordPlusNEURONS-
Appears in Collections:
KIST Article > 2019
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE