Full metadata record

DC Field Value Language
dc.contributor.authorPark, Chul Min-
dc.contributor.authorKwon, Seong-il-
dc.contributor.authorHong, Hanpyo-
dc.contributor.authorKang, Sungchul-
dc.contributor.authorJeon, In-Ho-
dc.contributor.authorPark, Shinsuk-
dc.contributor.authorKim, Keri-
dc.date.accessioned2024-01-19T22:30:51Z-
dc.date.available2024-01-19T22:30:51Z-
dc.date.created2021-09-03-
dc.date.issued2018-07-
dc.identifier.issn0140-0118-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/121187-
dc.description.abstractSeveral different flexible end effectors have been developed to solve the problem of approaching the lesion in a minimally invasive surgery. In this paper, we developed a wire-driven end effector device to treat frozen shoulder. Since the device is for capsular release surgery, it has a suitable bend radius for the surgery. It is a cylindrical cannula that can fit various surgical tools and can be sterilized after use. The end effector is made of an elastic material called PAI (polyamide-imide) with its outer diameter and total length being 4 and 19 mm. It is controlled by wires that are connected to a motor. Through quantitative evaluation, we confirmed that the end effector can bend up to 90A degrees in an upward or downward direction. Through qualitative evaluation, we confirmed that the device can easier access all regions of the glenoid in a shoulder model than conventional electrocautery. An experiment on a cadaver followed, which allowed us to discuss the real life performance, operation, and areas of improvement of the device with surgeons. From the experiments, we confirmed that our target region, the IGHL (inferior glenohumeral ligament), is within the reach of our device. The surgeon also evaluated that the control of the device caused no inconvenience.-
dc.languageEnglish-
dc.publisherSPRINGER HEIDELBERG-
dc.subjectSURGERY-
dc.subjectSYSTEM-
dc.subjectARTHROSCOPY-
dc.titleDevelopment and preclinical trials of a wire-driven end effector device for frozen shoulder treatment-
dc.typeArticle-
dc.identifier.doi10.1007/s11517-017-1759-y-
dc.description.journalClass1-
dc.identifier.bibliographicCitationMEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, v.56, no.7, pp.1149 - 1160-
dc.citation.titleMEDICAL & BIOLOGICAL ENGINEERING & COMPUTING-
dc.citation.volume56-
dc.citation.number7-
dc.citation.startPage1149-
dc.citation.endPage1160-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.identifier.wosid000435970600003-
dc.identifier.scopusid2-s2.0-85036564890-
dc.relation.journalWebOfScienceCategoryComputer Science, Interdisciplinary Applications-
dc.relation.journalWebOfScienceCategoryEngineering, Biomedical-
dc.relation.journalWebOfScienceCategoryMathematical & Computational Biology-
dc.relation.journalWebOfScienceCategoryMedical Informatics-
dc.relation.journalResearchAreaComputer Science-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaMathematical & Computational Biology-
dc.relation.journalResearchAreaMedical Informatics-
dc.type.docTypeArticle-
dc.subject.keywordPlusSURGERY-
dc.subject.keywordPlusSYSTEM-
dc.subject.keywordPlusARTHROSCOPY-
dc.subject.keywordAuthorFrozen shoulder-
dc.subject.keywordAuthorCapsular release surgery-
dc.subject.keywordAuthorEnd effector-
dc.subject.keywordAuthorMinimally invasive surgery-
Appears in Collections:
KIST Article > 2018
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE