Full metadata record

DC Field Value Language
dc.contributor.authorKang, Hyungmook-
dc.contributor.authorChoi, Sun-
dc.contributor.authorLee, Dae-Young-
dc.date.accessioned2024-01-19T22:31:59Z-
dc.date.available2024-01-19T22:31:59Z-
dc.date.created2021-09-03-
dc.date.issued2018-06-15-
dc.identifier.issn0360-5442-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/121246-
dc.description.abstractTo comprehend the underlying physics of desiccant wheel operation, a feasible analytic solution has been developed from a gas-side resistance model. As a continuation of development, in this study, the analytical model of the previous work is improved by extending the existing model to arbitrary split ratio case. Furthermore, to improve the accuracy for extended operation range of desiccant wheel, the humidity lines on psychrometric chart are separately represented by two gradients, psi(p) and psi(r), from process region and regeneration region. The analytic solution explicitly predicts the temperature and humidity ratio of the outlet air with a simple linear algebra calculation. The outlet air states from the analytical solution are compared with experimental results and with numerical results predicted by a gas-side resistance model according to various design and operation parameters. For various operation condition, the analytic solution demonstrates transient behaviors of the temperature and humidity ratio within the margin of 10% with respect to the root mean square error during whole cycle period, and shows the better prediction in the practical operation range. The simple time-averaged errors, which are more meaningful in practical sense, are surely observed even smaller than the root mean square errors, within 5%. (C) 2018 Published by Elsevier Ltd.-
dc.languageEnglish-
dc.publisherPERGAMON-ELSEVIER SCIENCE LTD-
dc.subjectNONLINEAR ANALOGY METHOD-
dc.subjectREGENERATION TEMPERATURE-
dc.subjectMASS-TRANSFER-
dc.subjectCONDITIONING SYSTEMS-
dc.subjectCOOLING SYSTEM-
dc.subjectDESIGN THEORY-
dc.subjectROTARY HEAT-
dc.subjectPERFORMANCE-
dc.subjectDEHUMIDIFICATION-
dc.subjectOPTIMIZATION-
dc.titleAnalytic solution to predict the outlet air states of a desiccant wheel with an arbitrary split ratio-
dc.typeArticle-
dc.identifier.doi10.1016/j.energy.2018.03.177-
dc.description.journalClass1-
dc.identifier.bibliographicCitationENERGY, v.153, pp.301 - 310-
dc.citation.titleENERGY-
dc.citation.volume153-
dc.citation.startPage301-
dc.citation.endPage310-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.identifier.wosid000436651100029-
dc.identifier.scopusid2-s2.0-85047462060-
dc.relation.journalWebOfScienceCategoryThermodynamics-
dc.relation.journalWebOfScienceCategoryEnergy & Fuels-
dc.relation.journalResearchAreaThermodynamics-
dc.relation.journalResearchAreaEnergy & Fuels-
dc.type.docTypeArticle-
dc.subject.keywordPlusNONLINEAR ANALOGY METHOD-
dc.subject.keywordPlusREGENERATION TEMPERATURE-
dc.subject.keywordPlusMASS-TRANSFER-
dc.subject.keywordPlusCONDITIONING SYSTEMS-
dc.subject.keywordPlusCOOLING SYSTEM-
dc.subject.keywordPlusDESIGN THEORY-
dc.subject.keywordPlusROTARY HEAT-
dc.subject.keywordPlusPERFORMANCE-
dc.subject.keywordPlusDEHUMIDIFICATION-
dc.subject.keywordPlusOPTIMIZATION-
dc.subject.keywordAuthorDesiccant wheel-
dc.subject.keywordAuthorAnalytic solution-
dc.subject.keywordAuthorGas-side resistance model-
dc.subject.keywordAuthorSplit ratio-
dc.subject.keywordAuthorLinearization of relative humidity lines-
Appears in Collections:
KIST Article > 2018
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE